RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
        • 등재정보
        • 학술지명
        • 주제분류
        • 발행연도
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        Pseudotumor and Subsequent Implant Loosening as a Complication of Revision Total Hip Arthroplasty with Ceramic-on-Metal Bearing: A Case Report

        Lokesh Gudda Naik,손원용,I.C. Clarke,문준규,Piyush Mukund,김상민 대한고관절학회 2018 Hip and Pelvis Vol.30 No.4

        Pseudotumors are not uncommon complications after total hip arthroplasty (THA) and may occur due to differences in bearing surfaces of the head and the liner ranging from soft to hard articulation. The most common causes of pseudotumors are foreign-body reaction, hypersensitivity and wear debris. The spectrum of pseudotumor presentation following THA varies greatly-from completely asymptomatic to clear implant failure. We report a case of pseudo-tumor formation with acetabular cup aseptic loosening after revision ceramic-onmetal hip arthroplasty. The patient described herein underwent pseudotumor excision and re-revision complex arthroplasty using a trabecular metal shell and buttress with ceramic-on-polyethylene THA. Surgeons should be aware of the possibility of a pseudotumor when dealing with revisions to help prevent rapid progression of cup loosening and implant failure, and should intervene early to avoid complex arthroplasty procedures.

      • KCI등재

        Comparative Study of Pinless Navigation System versus Conventional Instrumentation in Total Knee Arthroplasty

        Prashant Pawar,Lokesh Naik,Dipit Sahu,Vaibhav Bagaria 대한정형외과학회 2021 Clinics in Orthopedic Surgery Vol.13 No.3

        Background: Optimal placement of the components and achieving a neutral mechanical axis are the main goals of total knee arthroplasty (TKA). Different computerised navigation systems are presently used for these purposes. This aim of this study was to compare the pinless navigation (PNA) TKA performed using iAssist with the conventional instrumented (CIN) TKA in terms of functional and radiological outcomes. Methods: A total of 100 knees operated for TKA by a single surgeon were studied retrospectively for a period of 2 years. Weightbearing postoperative radiographs of the knees along with scanograms of the lower limbs were used for measurements of component positioning, mechanical axis alignment, and number of outliers. Oxford knee scoring was used for functional analysis. Results: No statistically significant difference was seen in the mean mechanical axis alignment (hip-knee-ankle angle), coronal alignment (α and β angles) and sagittal alignment (γ and δ angles) of the femoral and tibial components between the two groups. Though the percentage of outliers for mechanical axis alignment was lower in the PNA-TKA group than in the CIN-TKA group, the difference was not statistically significant (p = 0.73). The number of outliers for the femoral and tibial component positioning in coronal and sagittal planes was not statistically significantly different between the two groups. No statistically significant difference (p = 0.68) was noted between the two groups with respect to the Oxford Knee Score. The mean surgical time was greater in the PNA-TKA group by 11 minutes, which was statistically significantly longer (p = 0.018). Complications were seen in 6.89% of the cases in the CIN-TKA group, while none in the PNA-TKA group. Conclusions: The accurate mechanical axis alignment and component positioning can be achieved with the conventional instrumentation, so the use of PNA system, which adds to the surgical cost, is questionable. Also, equally good short-term functional outcome can be achieved with the conventional instrumentation. The surgeon must be accustomed with the instrumentation of the PNA system, or it adds to the surgical time.

      • KCI등재

        Anthropometry of Nonarthritic Asian Knees: Is It Time for a Race-Specific Knee Implant?

        Mohan Hariharan,Chhabria Prasidh,Bagaria Vaibhav,Tadepalli Kalyan,Naik Lokesh,Kulkarni Rajiv 대한정형외과학회 2020 Clinics in Orthopedic Surgery Vol.12 No.2

        Background: This study was done to study the anthropometry of nonarthritic Asian knees; to determine the differences in morphology between knees of different ethnicities and to compare the knee anthropometry values with sizes of available knee implants. Methods: Magnetic resonance imaging scans of 100 nonarthritic Indian knees were analyzed. Anteroposterior (AP) length, mediolateral (ML) length, and aspect ratio of the distal femur and proximal tibia, patellar length, and patellar tendon length were measured. These values were compared with values of other ethnicities from literature. The values were also compared with sizes of available knee implants and evaluated for mismatch. Results: All the parameters of female knees were significantly smaller than those of male knees (p < 0.05). The distal femur of Indian knees resembled that of Chinese knees with similar AP and ML lengths and aspect ratio. The distal femur of Indian knees had a significantly smaller AP, ML, and aspect ratio than those of Hispanic knees did. In comparison to Caucasian distal femur, Indian knees had smaller AP and ML lengths and larger aspect ratio. In terms of the proximal tibia, the Indian knees were smaller than Chinese (only ML), Caucasian (AP and ML) and Hispanic (AP and ML) knees. On comparison with implant sizes, there was a mismatch between the distal femur morphology and the dimensions of all implants. For a given AP length, the ML dimensions of all implants were smaller than the measured ML length of the knee. However, the tibial components of all the studied implants correlated well with the tibial morphology. Conclusions: Distinct anthropometric differences exist between knees of different ethnicities. The knees of females were smaller than the knees of males. In Indian knees, the ML-AP aspect ratio of the distal femur was higher than that of the currently available femoral components. These results suggest the need for race-specific knee implants.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼