http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
돌출길이 및 air gap size에 따른 가스분무 조업 시 가스거동 해석
권의혁 ( Eui Hyuk Kwon ),정훈제 ( Hun Je Jung ),장경수 ( Kyoung Soo Jang ),구용모 ( Yong Mo Koo ),한정환 ( Jeong Whan Han ) 대한금속재료학회(구 대한금속학회) 2014 대한금속·재료학회지 Vol.52 No.4
The optimization of the gas atomization for particle size control and optimal energy efficiency cannot be achieved simply, due to the lack of understanding of the basic atomization process. A numerical analysis is performed in order to optimize the manufacturing process and to understand the behavior of the gas at the end of the nozzle. In this study, the gas flow is analyzed numerically using a computational fluid dynamics software package (Fluent). It is found that a protrusion length of 3 mm is optimal for nozzles with a quick gas velocity and stable aspiration pressure. In addition, the impact on the air gap size is also investigated.
회전근 개 층간 분리 파열에서 관절경을 이용한 층상 교량형 봉합술의 임상 결과
최의성(Eui-Sung Choi),박경진(Kyoung-Jin Park),김용민(Yong-Min Kim),김동수(Dong-Soo Kim),손현철(Hyun-Chul Shon),조병기(Byung-Ki Cho),박지강(Ji-Kang Park),김동환(Dong-Whan Kim),금상욱(Sang-Wook Keum),차정권(Jung-Kwon Cha) 대한견주관절의학회 2013 대한견주관절의학회지 Vol.16 No.2
목적: 저자들은 회전근 개 파열 중 층간 분리 파열의 새로운 수술 방법인 층상 교량형 봉합술을 고안하고, 이 수술법을 이용하여 치료한 환자들의 임상 결과와 회전근 개 치유 정도에 대해 전향적으로 연구하였다. 대상 및 방법: 회전근 개 전층 파열로 층상 교량형 봉합술을 이용하여 수술한 환자 66명(67예)을 대상으로 하였다. 평균 추시 기간은 33개월이었으며, 임상적 결과의 평가는 수술 전과 수술 후 KSS점수, UCLA점수, ASES점수를 이용하였고, 수술 후 6개월째 자기공명영상 검사를 촬영하였다. 결과: KSS점수, UCLA점수, ASES점수는 각각 54.4점에서 90.7점, 15점에서 31.3점, 50.2점에서 92.3점으로 큰 호전을 보였다. 수술 후 6개월째 자기공명영상 검사를 추적 관찰한 38명의 환자에서 92%의 높은 비율의 해부학적 치유를 보였으며, 재파열(IV, V단계)의 비율은 7.9%였다. 결론: 회전근 개 전층 파열 환자 중 층간 분리 파열의 경우 관절경적 층상 교량형 봉합술을 이용한 수술시 해부학적으로 회전근 개의 우수한 치유 결과를 얻었으며, 임상적, 기능적으로도 우수한 결과를 얻을 수 있었다. Purpose: The purpose of this study was to evaluate the repair integrity and clinical outcomes of delaminated tears following arthroscopic layered suture bridge rotator cuff repair in a prospective fashion. Materials and Methods: A consecutive series of 67 patients with delaminated rotator cuff tears who underwent surgery using the arthroscopic Layered Suture Bridge Technique were followed prospectively. Of 67 shoulders, 26 patients were male and 40 patients were female (one patient had bilateral tears); the mean age was 58.8(40~76) years. The clinical evaluation was performed according to ASES, UCLA, and KSS (Korea Shoulder Scoring System) scores with an average follow up period of 33 months. Repair integrity was estimated using MRI, which was performed six months postoperatively. Results: The average clinical outcome in ASES, UCLA, and KSS scores showed significant improvement at the time of the final follow-up compared to preoperatively, from 50.2 to 92.3, 15 to 31.3, and 54.4 to 90.7, respectively (p<0.001 for all scores). Follow up by MRI showed that 16 shoulders had a type-I; 14, a type-II; five, a type-III; two, a type-IV; one, a type-V re-tear. The overall rate of re-tear (types IV and V) was 7.9%. Conclusion: Use of the Arthroscopic Layered Suture Bridge Technique can result in improved functional and structural outcome in cases of delaminated rotator cuff tear.
갈릴리안 광학계를 사용한 IM/DD 광무선통신 시스템에서 830[nm] 광파장에 대한 전송거리 제한 해석
홍권의(Kwon-Eui Hong),고성원(Sung-Won Ko),조정환(Jung-Whan Cho) 한국조명·전기설비학회 2011 조명·전기설비학회논문지 Vol.25 No.11
In terrestrial wireless optical communication links, atmospheric effects including turbulence, absorption and scattering have significant impact on the system performance. Based on the analysis of transmission in atmospheric channel concerning 830[nm] wavelength diode laser beam, performance of free space optical (FSO) link utilizing Galilean optics as a laser beam transmitting and receving optics, PIN photodiode as a detecting device. In this paper we designed optical link equation for received optical power and we analyze the atmospheric effects on the signal to noise ratio (SNR) and bit error rate (BER) of an terrestrial FSO system. We show that the possible communication distance for BER=10<sub>-9</sub> in proposed adverse atmospheric conditions.
평면이방성 암석의 단일시험편에서 탄성상수 결정에 제안된 수식들의 적용연구
박철환(Chul-Whan Park),박찬(Chan Park),정용복(Yong-Bok Jung),박의섭(Eui-Seob Park) 한국암반공학회 2010 터널과지하공간 Vol.20 No.3
단일시험편의 일축압축시험에서 평면이방성 암석의 5개의 독립적 탄성상수를 얻기 위하여 제 5의 수식이 반드시 필요하다. Saint-Venant에 의하여 제안된 근사식은 오랫동안 전통적으로 사용되어 왔지만 시험편의 특성에 따라 문제를 해결하지 못하는 경우가 있다. 지난 일련의 연구에서 이 식을 대체할 수 있는 3개의 수식이 제안되었으며, 모델연구를 통하여 이들은 적용가능한 수식으로 밝혀졌다. Saint-Venant 근사식은 제안된 식들 가운데 첫째식과 같은 것으로 밝혀졌는데, 이로서 겉보기 탄성계수는 이방성각도에 따른 단조증가함수라는 특성이 있다. 본 연구에서는 단일시험편에 대한 일축압축시험을 수행하여 얻어진 4개의 독립적 변형률로부터 탄성상수를 구하는 자세한 방법이 언급되었으며, 제안된 수식의 필요성과 적합성이 검토되었다. 이방성각도가 중간 또는 큰 크기일 때에는 Saint-Venant 근사식의 적용으로 참값에 가까운 탄성상수를 결정할 수 있기 때문에 다른 수식의 제안은 필요하지 않다. 그럼에도 불구하고 제안된 식들은 이와 비슷한 결과를 유도하므로 적용가능하다고 판단된다. 이방성각도가 작은 경우에는 Saint-Venant 근사식으로 일반적인 여러 구속조건을 만족시키는 값을 얻지 못하는 반면에, 제안된 식들은 참값에 가까운 결과를 유도할 수 있었다. 따라서 보다 더 적합한 수식이 알려지기 전에는 이들 식을 적용하는 것을 제안한다. 모델연구에서 얻어진 지침도를 활용하면, 3개의 수식 가운데 가장 적합한 수식을 결정할 수 있다. A fifth equation is required to determine the five independent elastic constants of a transversely isotropic rock from compression test of a single specimen. As an approximation proposed by Saint-Venant has been used for long time, it may cause an erroneous result in some cases, especially for specimen with low angle of anisotropy. Three equations were suggested replacing this traditional equation and proved to be applicable by the model analysis in the previous studies. As Saint-Venant's approximation is turned out the same as the first one of them, it has the characteristics that the apparent Young's modulus is monotonously increasing according to the anisotropic angle. The methodology to analyze the elastic constants from four independent strain measurements by uniaxial compressive test of a single standard specimen is concisely described, and the necessity and compatibility of new suggested equations are discussed. Saint-Venant’s approximation can determine the elastic constants close to true values and other equations may be unnecessary in specimens with medium to large angle. Nevertheless, they may become applicable because they can produce the almost same amount. For the specimens of small angle of anisotropy, Saint-Venant's approximation may result in out of general ranges or thermodynamic constraints, but other suggested equations can produce the almost true value. Thus they can be applied before other alternative equation is known. The guide map constructed by model study may decide the most compatible one of the three equations.