RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        Hydrogen Sorption of Porous Tungsten Oxide Nanomaterial and Effect of a Pd Coating on its Storage Capacity Under Hydrogenation Cycles

        D. E. Diaz-Droguett,S. Rojas,M. Roble 성균관대학교(자연과학캠퍼스) 성균나노과학기술원 2018 NANO Vol.13 No.09

        The H2 uptake performance at room temperature of porous tungsten oxide nanomaterials with and without a catalytic Pd coating was studied by the quartz crystal microbalance technique. Tungsten oxide composed mainly of WO3 was synthesized by inert gas condensation method using He. The samples consisted of semi-amorphous nanomaterials of low crystallinity and high porosity, as revealed by SAED, TEM, XRD, Raman spectroscopy and N2 adsorption–desorption isotherms. The H2 uptake capacity of the porous oxide was studied under increasing H2 exposure pressures (1000–7000 Pa), with and without Pd coating. After reaching a maximum value of 1.2 H2 wt.%, at 1160 Pa, the H2 uptake capacity of the Pd-coated oxide consistently decreased. Successive hydrogenation cycles were carried out on the Pd-coated oxide at 3300 Pa and 6000 Pa to evaluate the H2 uptake performance of the sample under this H2 loading and unloading process. It was found that the H2 uptake capacity decreased from around 1 to values below 0.53 H2 wt.%, which is the reference H2 storage capacity achieved by a 15 nm-thick Pd film. We argued that water molecule formation in the Pd/oxide interface and sublayers negatively affects the H2 uptake capacity of the oxide under successive hydrogenation cycles at room temperature.

      • Diagnostic Yield of Primary Circulating Tumor Cells in Women Suspected of Breast Cancer: the BEST (Breast Early Screening Test) Study

        Murray, Nigel P,Miranda, Roxana,Ruiz, Amparo,Droguett, Elsa Asian Pacific Journal of Cancer Prevention 2015 Asian Pacific journal of cancer prevention Vol.16 No.5

        Purpose: To determine the diagnostic yield of primary circulating tumor cells in women with suspicion of breast cancer, detected as a result of an abnormal mammography. Materials and Methods: Consecutive women presenting for breast biopsy as a result of a mammogram BiRADs of 3 or more, had an 8ml blood sample taken for primary circulating tumor cell (CTC) detection. Mononuclear cells were obtained using differential gel centrifugation and CTCs identified using standard immunocytochemistry using anti-mammoglobin. A test was determined to be positive if 1 CTC was detected. Results: A total of 144 women with a mean age of $54.7{\pm}15.6$ years participated, 78/144 (53.0%) had breast cancer on biopsy, 65/140 (46.3%) benign pathologies and 1(0.7%) non-Hogkins lymphoma. Increasing BiRADs scores were associated with increased cancer detection (p=0.004, RR 1.00, 4.24, 8.50). CTC mammoglobin positive had a sensitivity of 81.1% and specificity of 90.9%, with positive and negative predictive values of 90.9% and 81.1% respectively. Mammoglobin positive CTCs detected 87% of invasive cancers, while poorly differentiated cancers were negative for mammoglobin. Only 50% of in situ cancers and none of the intraductal cancers had CTCs detected. Menopausal status did not affect the diagnostic yield of the CTC test, which was higher in women with BiRADS 4 mammograms. There was a significant trend (p<0.0001 Chi squared for trends) in CTC detection frequency from intraductal, in situ and invasive (OR 1.00, 8.00, 472.00). Conclusions: The use of primary CTC detection in women suspected of breast cancer has potential uses, especially with invasive cancer, but it failed to detect intra-ductal cancer and 50% of in situ cancer. There was no difference in the diagnostic yield between pre and post menopausal women. To confirm its use in reducing biopsies in women with BIRADs 4a mammagrams and in the detection of interval invasive breast cancer, larger studies are needed.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼