RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
        • 등재정보
        • 학술지명
        • 주제분류
        • 발행연도
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        Interface between calcium silicate cement and adhesive systems according to adhesive families and cement maturation

        Pradelle-Plasse Nelly,Mocquot Caroline,Semennikova Katherine,Colon Pierre,Grosgogeat Brigitte 대한치과보존학회 2021 Restorative Dentistry & Endodontics Vol.46 No.1

        Objectives: This study aimed to evaluate the interface between a calcium silicate cement (CSC), Biodentine and dental adhesives in terms of sealing ability. Materials and Methods: Microleakage test: 160 standardized class II cavities were prepared on 80 extracted human molars. The cavities were filled with Biodentine and then divided into 2 experimental groups according to the time of restoration: composite resin obturation 15 minutes after Biodentine handling (D0); restoration after 7 days (D7). Each group was then divided into 8 subgroups (n = 5) according to the adhesive system used: etch-and-rinse adhesive (Prime & Bond); self-etch adhesive 2 steps (Optibond XTR and Clearfil SE Bond); self-etch adhesive 1 step (Xeno III, G-aenial Bond, and Clearfil Tri-S Bond); and universal used as etch-and-rinse or self-etch (ScotchBond Universal ER or SE). After thermocycling, the teeth were immersed in a silver nitrate solution, stained, longitudinally sectioned, and the Biodentine/adhesive percolation was quantified. Scanning electron microscopic observations: Biodentine/adhesive interfaces were observed. Results: A tendency towards less microleakage was observed when Biodentine was etched (2.47%) and when restorations were done without delay (D0: 4.31%, D7: 6.78%), but this was not significant. The adhesives containing 10-methacryloyloxydecyl dihydrogen phosphate monomer showed the most stable results at both times studied. All Biodentine/adhesive interfaces were homogeneous and regular. Conclusions: The good sealing of the CSC/adhesive interface is not a function of the system adhesive family used or the cement maturation before restoration. Biodentine can be used as a dentine substitute.

      • KCI등재

        Comparison of mechanical properties of a new fiber reinforced composite and bulk filling composites

        Abouelleil, Hazem,Pradelle, Nelly,Villat, Cyril,Attik, Nina,Colon, Pierre,Grosgogeat, Brigitte The Korean Academy of Conservative Dentistry 2015 Restorative Dentistry & Endodontics Vol.40 No.4

        Objectives: The aim of this study was to evaluate the mechanical and physical properties of a newly developed fiber reinforced dental composite. Materials and Methods: Fiber reinforced composite EverX Posterior (EXP, GC EUROPE), and other commercially available bulk fill composites, including Filtek Bulk Fill (FB, 3M ESPE), SonicFill (SF, Kerr Corp.), SureFil (SDR, Dentsply), Venus Bulk Fill (VB, HerausKultzer), Tetric evoceram bulk fill (TECB, Ivoclar Vivadent), and Xtra Base (XB, Voco) were characterized. Composite samples light-cured with a LED device were evaluated in terms of flexural strength, flexural modulus (ISO 4049, n = 6), fracture toughness (n = 6), and Vickers hardness (0, 2, and 4 mm in depth at 24 hr, n = 5). The EXP samples and the fracture surface were observed under a scanning electron microscopy. Data were statistically analyzed using one-way ANOVA and unpaired t-test. Results: EXP, FB, and VB had significantly higher fracture toughness value compared to all the other bulk composite types. SF, EXP, and XB were not statistically different, and had significantly higher flexural strength values compared to other tested composite materials. EXP had the highest flexural modulus, VB had the lowest values. Vickers hardness values revealed SF, EXP, TECB, and XB were not statistically different, and had significantly higher values compared to other tested composite materials. SEM observations show well dispersed fibers working as a reinforcing phase. Conclusions: The addition of fibers to methacrylate-based matrix results in composites with either comparable or superior mechanical properties compared to the other bulk fill materials tested.

      • KCI등재

        Comparison of mechanical properties of a new fiber reinforced composite and bulk filling composites

        Hazem Abouelleil,Nelly Pradelle,Cyril Villat,Nina Attik,Pierre Colon,Brigitte Grosgogeat 대한치과보존학회 2015 Restorative Dentistry & Endodontics Vol.40 No.4

        Objectives: The aim of this study was to evaluate the mechanical and physical properties of a newly developed fiber reinforced dental composite. Materials and Methods: Fiber reinforced composite EverX Posterior (EXP, GC EUROPE), and other commercially available bulk fill composites, including Filtek Bulk Fill (FB, 3M ESPE), SonicFill (SF, Kerr Corp.), SureFil (SDR, Dentsply), Venus Bulk Fill (VB, HerausKultzer), Tetric evoceram bulk fill (TECB, Ivoclar Vivadent), and Xtra Base (XB, Voco) were characterized. Composite samples light-cured with a LED device were evaluated in terms of flexural strength, flexural modulus (ISO 4049, n = 6), fracture toughness (n = 6), and Vickers hardness (0, 2, and 4 mm in depth at 24 hr, n = 5). The EXP samples and the fracture surface were observed under a scanning electron microscopy. Data were statistically analyzed using one-way ANOVA and unpaired t-test. Results: EXP, FB, and VB had significantly higher fracture toughness value compared to all the other bulk composite types. SF, EXP, and XB were not statistically different, and had significantly higher flexural strength values compared to other tested composite materials. EXP had the highest flexural modulus, VB had the lowest values. Vickers hardness values revealed SF, EXP, TECB, and XB were not statistically different, and had significantly higher values compared to other tested composite materials. SEM observations show well dispersed fibers working as a reinforcing phase. Conclusions: The addition of fibers to methacrylate-based matrix results in composites with either comparable or superior mechanical properties compared to the other bulk fill materials tested.

      • SCOPUSKCI등재

        Preoperative chemoradiotherapy versus postoperative chemoradiotherapy for stage II-III resectable rectal cancer: a meta-analysis of randomized controlled trials

        Song, Jin Ho,Jeong, Jae Uk,Lee, Jong Hoon,Kim, Sung Hwan,Cho, Hyeon Min,Um, Jun Won,Jang, Hong Seok,Korean Clinical Practice Guideline for Colon and Rectal Cancer Committee The Korean Society for Radiation Oncology 2017 Radiation Oncology Journal Vol.35 No.3

        Purpose: Whether preoperative chemoradiotherapy (CRT) is better than postoperative CRT in oncologic outcome and toxicity is contentious in prospective randomized clinical trials. We systematically analyze and compare the treatment result, toxicity, and sphincter preservation rate between preoperative CRT and postoperative CRT in stage II-III rectal cancer. Materials and Methods: We searched Medline, Embase, and Cochrane Library from 1990 to 2014 for relevant trials. Only phase III randomized studies performing CRT and curative surgery were selected and the data were extracted. Meta-analysis was used to pool oncologic outcome and toxicity data across studies. Results: Three randomized phase III trials were finally identified. The meta-analysis results showed significantly lower 5-year locoregional recurrence rate in the preoperative-CRT group than in the postoperative-CRT group (hazard ratio, 0.59; 95% confidence interval, 0.41-0.84; p = 0.004). The 5-year distant recurrence rate (p = 0.55), relapse-free survival (p = 0.14), and overall survival (p = 0.22) showed no significant difference between two groups. Acute toxicity was significantly lower in the preoperative-CRT group than in the postoperative-CRT group (p < 0.001). However, there was no significant difference between two groups in perioperative and chronic complications (p = 0.53). The sphincter-saving rate was not significantly different between two groups (p = 0.24). The conversion rate from abdominoperineal resection to low anterior resection in low rectal cancer was significantly higher in the preoperative-CRT group than in the postoperative-CRT group (p < 0.001). Conclusions: As compared to postoperative CRT, preoperative CRT improves only locoregional control, not distant control and survival, with similar chronic toxicity and sphincter preservation rate in rectal cancer patients.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼