http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Study on the cultural risk of organizational knowledge management
CHEN Faxiang,LIANG Changyong 인하대학교 정석물류통상연구원 2009 인하대학교 정석물류통상연구원 학술대회 Vol.2009 No.10
Knowledge Management has gained more and more popularity in the organizational management field today. However, many companies can not get the result that they expected when they initiated knowledge management program. One of the main issues is that the organizational culture is not fully considered and resolved. This paper is based on studies on the relationship between types of knowledge management and organizational culture type and knowledge management performance. With fully discussion and empirical studies, this paper shows that elaborated organizational culture has an important contribution to the success of knowledge management.
Wonkook Kim,Changyong Cao,Shunlin Liang IEEE 2014 IEEE geoscience and remote sensing letters Vol.11 No.4
<P>Radiometric sensor calibration is critical for quantitative use of the data obtained from the FeungYun-3A MEdium-Resolution Spectral Imager (MERSI) sensor. To meet the required calibration criteria, several vicarious calibration (VC) techniques are being employed in the current operational calibration of MERSI. This letter presents the independent results of sensor degradation assessment which were obtained directly from sequences of top-of-atmosphere (TOA) reflectance from calibration sites. The absolute calibration approaches and the desert tracking approach used in the current operational process involve a radiative transfer model (RTM) when simulating the reference TOA reflectance. However, collecting synchronous in situ measurements for an RTM is usually expensive and time consuming, thus greatly limiting the frequency of such calibration processes. The direct approach developed in this study is an efficient and complementary VC technique that can increase the reliability of VC results in concert with other techniques. TOA reflectance measurements from three pseudoinvariant calibration sites are used to estimate sensor degradation rates. The results are compared with those obtained by other operational methods such as the multisite and the deep convective cloud tracking methods. The direct approach is consistent across the three calibration sites, producing degradation estimates comparable to those of the two other operational methods, suggesting the effectiveness of the direct approach for the MERSI radiometric sensor calibration.</P>