http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Dias Pedro de Souza,Kato Augusto Shoji,Bueno Carlos Eduardo da Silveira,Vivan Rodrigo Ricci,Duarte Marco Antonio Hungaro,Calefi Pedro Henrique Souza,Pelegrine Rina Andréa 대한치과보존학회 2023 Restorative Dentistry & Endodontics Vol.48 No.1
Objectives This study aimed to compare the torsional and cyclic fatigue resistance of ProGlider (PG), WaveOne Gold Glider (WGG), and TruNatomy Glider (TNG). Materials and Methods A total of 15 instruments of each glide path system (n = 15) were used for each test. A custom-made device simulating an angle of 90° and a radius of 5 millimeters was used to assess cyclic fatigue resistance, with calculation of number of cycles to failure. Torsional fatigue resistance was assessed by maximum torque and angle of rotation. Fractured instruments were examined by scanning electron microscopy (SEM). Data were analyzed with Shapiro-Wilk and Kruskal-Wallis tests, and the significance level was set at 5%. Results The WGG group showed greater cyclic fatigue resistance than the PG and TNG groups (p < 0.05). In the torsional fatigue test, the TNG group showed a higher angle of rotation, followed by the PG and WGG groups (p < 0.05). The TNG group was superior to the PG group in torsional resistance (p < 0.05). SEM analysis revealed ductile morphology, typical of the 2 fracture modes: cyclic fatigue and torsional fatigue. Conclusions Reciprocating WGG instruments showed greater cyclic fatigue resistance, while TNG instruments were better in torsional fatigue resistance. The significance of these findings lies in the identification of the instruments’ clinical applicability to guide the choice of the most appropriate instrument and enable the clinician to provide a more predictable glide path preparation.
Fernanda Garcia Tampelini,Marcelo Santos Coelho,Marcos de Azevêdo Rios,Carlos Eduardo Fontana,Daniel Guimarães Pedro Rocha,Sergio Luiz Pinheiro,Carlos Eduardo da Silveira Bueno 대한치과보존학회 2017 Restorative Dentistry & Endodontics Vol.42 No.3
Objectives: The aim of this in vivo study was to assess the accuracy of 2 third-generation electronic apex locators (EALs), Propex II (Dentsply Maillefer) and Root ZX II (J. Morita), and radiographic technique for locating the major foramen (MF). Materials and Methods: Thirty-two premolars with single canals that required extraction were included. Following anesthesia, access, and initial canal preparation with size 10 and 15 K-flex files and SX and S1 rotary ProTaper files, the canals were irrigated with 2.5% sodium hypochlorite. The length of the root canal was verified 3 times for each tooth using the 2 apex locators and once using the radiographic technique. Teeth were extracted and the actual WL was determined using size 15 K-files under a × 25 magnification. The Biostat 4.0 program (AnalystSoft Inc.) was used for comparing the direct measurements with those obtained using radiographic technique and the apex locators. Pearson's correlation analysis and analysis of variance (ANOVA) were used for statistical analyses. Results: The measurements obtained using the visual method exhibited the strongest correlation with Root ZX II (r = 0.94), followed by Propex II (r = 0.90) and Ingle's technique (r = 0.81; p < 0.001). Descriptive statistics using ANOVA (Tukey's post hoc test) revealed significant differences between the radiographic measurements and both EALs measurements (p < 0.05). Conclusions: Both EALs presented similar accuracy that was higher than that of the radiographic measurements obtained with Ingle's technique. Our results suggest that the use of these EALs for MF location is more accurate than the use of radiographic measurements.
Wang Andréa Huey Tsu,Panzarella Francine Kühl,Fontana Carlos Eduardo,Junqueira José Luiz Cintra,Bueno Carlos Eduardo da Silveira 대한영상치의학회 2023 Imaging Science in Dentistry Vol.53 No.1
Purpose: This study compared the accuracy of detection of incomplete vertical root fractures (VRFs) in filled and unfilled teeth on cone-beam computed tomography images with and without a metal artefact reduction (MAR) algorithm. Materials and Methods: Forty single-rooted maxillary premolars were selected and, after endodontic instru- mentation, were categorized as unfilled teeth without fractures, filled teeth without fractures, unfilled teeth with fractures, or filled teeth with fractures. Each VRF was artificially created and confirmed by operative microscopy. The teeth were randomly arranged, and images were acquired with and without the MAR algorithm. The images were evaluated with OnDemand software (Cybermed Inc., Seoul, Korea). After training, 2 blinded observers each assessed the images for the presence and absence of VRFs 2 times separated by a 1-week interval. P-values<0.05 were considered to indicate significance. Results: Of the 4 protocols, unfilled teeth analysed with the MAR algorithm had the highest accuracy of incomplete VRF diagnosis (0.65), while unfilled teeth reviewed without MAR were associated with the least accurate diagnosis (0.55). With MAR, an unfilled tooth with an incomplete VRF was 4 times more likely to be identified as having an incomplete VRF than an unfilled tooth without this condition, while without MAR, an unfilled tooth with an incomplete VRF was 2.28 times more likely to be identified as having an incomplete VRF than an unfilled tooth without this condition. Conclusion: The use of the MAR algorithm increased the diagnostic accuracy in the detection of incomplete VRF on images of unfilled teeth.
Tampelini, Fernanda Garcia,Coelho, Marcelo Santos,de Azevedo Rios, Marcos,Fontana, Carlos Eduardo,Rocha, Daniel Guimaraes Pedro,Pinheiro, Sergio Luiz,da Silveira Bueno, Carlos Eduardo The Korean Academy of Conservative Dentistry 2017 Restorative Dentistry & Endodontics Vol.42 No.3
Objectives: The aim of this in vivo study was to assess the accuracy of 2 third-generation electronic apex locators (EALs), Propex II (Dentsply Maillefer) and Root ZX II (J. Morita), and radiographic technique for locating the major foramen (MF). Materials and Methods: Thirty-two premolars with single canals that required extraction were included. Following anesthesia, access, and initial canal preparation with size 10 and 15 K-flex files and SX and S1 rotary ProTaper files, the canals were irrigated with 2.5% sodium hypochlorite. The length of the root canal was verified 3 times for each tooth using the 2 apex locators and once using the radiographic technique. Teeth were extracted and the actual WL was determined using size 15 K-files under a ${\times}25$ magnification. The Biostat 4.0 program (AnalystSoft Inc.) was used for comparing the direct measurements with those obtained using radiographic technique and the apex locators. Pearson's correlation analysis and analysis of variance (ANOVA) were used for statistical analyses. Results: The measurements obtained using the visual method exhibited the strongest correlation with Root ZX II (r = 0.94), followed by Propex II (r = 0.90) and Ingle's technique (r = 0.81; p < 0.001). Descriptive statistics using ANOVA (Tukey's post hoc test) revealed significant differences between the radiographic measurements and both EALs measurements (p < 0.05). Conclusions: Both EALs presented similar accuracy that was higher than that of the radiographic measurements obtained with Ingle's technique. Our results suggest that the use of these EALs for MF location is more accurate than the use of radiographic measurements.
Bengoa, Fernando Pena,Arze, Maria Consuelo Magasich,Noguera, Cristobal Macchiavello,Moreira, Luiz Felipe Nunes,Kato, Augusto Shoji,Da Silveira Bueno, Carlos Eduardo The Korean Academy of Conservative Dentistry 2020 Restorative Dentistry & Endodontics Vol.45 No.1
Objective: This study aimed to evaluate the effect of ultrasonic cleaning of the intracanal post space on the bond strength of fiber posts in oval canals filled with a premixed bioceramic (Bio-C Sealer [BIOC]) root canal sealer. Materials and Methods: Fifty premolars were endodontically prepared and divided into 5 groups (n = 10), based on the type of root canal filling material used and the post space cleaning protocol. A1: gutta-percha + AH Plus (AHP) and post space preparation with ultrasonic cleaning, A2: gutta-percha + BIOC and post space preparation with ultrasonic cleaning, B1: gutta-percha + AHP and post space preparation, B2: gutta-percha + BIOC and post space preparation, C: control group. Fiber posts were cemented with a self-adhesive luting material, and 1 mm thick slices were sectioned from the middle and cervical third to evaluate the remaining filling material microscopically. The samples were subjected to a push-out test to analyze the bond strength of the fiber post, and the results were analyzed with the Shapiro-Wilk, Bonferroni, Kruskal-Wallis, and Mann-Whitney tests (p < 0.05). Failure modes were evaluated using optical microscopy. Results: The results showed that the fiber posts cemented in canals sealed with BIOC had lower bond strength than those sealed with AHP. The ultrasonic cleaning of the post space improved the bond strength of fiber posts in canals sealed with AHP, but not with BIOC. Conclusions: BIOC decreased the bond strength of fiber posts in oval canals, regardless of ultrasonic cleaning.
Peña Bengoa Fernando,Magasich Arze Maria Consuelo,Macchiavello Noguera Cristobal,Moreira Luiz Felipe Nunes,Kato Augusto Shoji,Bueno Carlos Eduardo Da Silveira 대한치과보존학회 2020 Restorative Dentistry & Endodontics Vol.45 No.2
Objective: This study aimed to evaluate the effect of ultrasonic cleaning of the intracanal post space on the bond strength of fiber posts in oval canals filled with a premixed bioceramic (Bio-C Sealer [BIOC]) root canal sealer. Materials and Methods: Fifty premolars were endodontically prepared and divided into 5 groups (n = 10), based on the type of root canal filling material used and the post space cleaning protocol. A1: gutta-percha + AH Plus (AHP) and post space preparation with ultrasonic cleaning, A2: gutta-percha + BIOC and post space preparation with ultrasonic cleaning, B1: gutta-percha + AHP and post space preparation, B2: gutta-percha + BIOC and post space preparation, C: control group. Fiber posts were cemented with a self-adhesive luting material, and 1 mm thick slices were sectioned from the middle and cervical third to evaluate the remaining filling material microscopically. The samples were subjected to a push-out test to analyze the bond strength of the fiber post, and the results were analyzed with the Shapiro-Wilk, Bonferroni, Kruskal-Wallis, and Mann-Whitney tests (p < 0.05). Failure modes were evaluated using optical microscopy. Results: The results showed that the fiber posts cemented in canals sealed with BIOC had lower bond strength than those sealed with AHP. The ultrasonic cleaning of the post space improved the bond strength of fiber posts in canals sealed with AHP, but not with BIOC. Conclusions: BIOC decreased the bond strength of fiber posts in oval canals, regardless of ultrasonic cleaning.