        Helical coils augment embolization of the middle meningeal artery for treatment of chronic subdural hematoma: A technical note

        Arvin R. Wali,Alexander Himstead,Javier Bravo,Michael G Brandel,Brian R. Hirshman,J. Scott Pannell,Andrew D. Nguyen,David R. Santiago-Dieppa 대한뇌혈관외과학회 2023 Journal of Cerebrovascular and Endovascular Neuros Vol.25 No.2

        Embolization of the middle meningeal artery (MMA) is a safe and effective adjunct in the treatment of chronic subdural hematoma. While prior authors describe the use of coils to assist embolization by preventing reflux through eloquent collaterals, we de- scribe the use of coils to further open the MMA, allowing the administration of greater amounts of embolisate for a more robust embolization. The objective of this study was to demonstrate that helical coils can safely open the MMA following the administration of polyvinyl alcohol (PVA) particles. This allows for more embolisate to be administered into the MMA for more effective treatment. A retrospective review was conducted at our institution including intraoperative images and postoperative clinical and radiographic follow up. Failure rates using MMA embolization with PVA and helical coil augmentation were compared to failure rates in the literature of MMA embolization with PVA or ethylene vinyl-alcohol copolymer alone. A total of 8 cases were reviewed in which this technique was implemented. There were no immediate complications after treatment. All patients that underwent helical coil embolization following the administration of PVA had increased amount of embolisate delivered into the MMA. All patients at follow up had resolution of the subdural hematoma on outpatient imaging. Helical coil embolization allows for more embolisate administration into the MMA and provides a technical advantage for patients that fail traditional techniques of embolization. Case series are taking place to further test this hypothesis and identify the ideal patient population that may gain maximal yield from this novel technique.

      • KCI등재

        Reducing frame rate and pulse rate for routine diagnostic cerebral angiography: ALARA principles in practice

        Arvin R. Wali,Sarath Pathuri,Michael G. Brandel,Ryan W. Sindewald,Brian R.Hirshman,Javier A. Bravo,Jeffrey A. Steinberg,Scott E. Olson,Jeffrey S. Pannell,Alexander Khalessi,David Santiago-Dieppa 대한뇌혈관외과학회 2024 Journal of Cerebrovascular and Endovascular Neuros Vol.26 No.1

        Objective: Diagnostic cerebral angiograms (DCAs) are widely used in neurosurgery due to their high sensitivity and specificity to diagnose and characterize pathology using ionizing radiation. Eliminating unnecessary radiation is critical to reduce risk to patients, providers, and health care staff. We investigated if reducing pulse and frame rates during routine DCAs would decrease radiation burden without compromising image quality.Methods: We performed a retrospective review of prospectively acquired data after implementing a quality improvement protocol in which pulse rate and frame rate were reduced from 15 p/s to 7.5 p/s and 7.5 f/s to 4.0 f/s respectively. Radiation doses and exposures were calculated. Two endovascular neurosurgeons reviewed randomly selected angiograms of both doses and blindly assessed their quality.Results: A total of 40 consecutive angiograms were retrospectively analyzed, 20 prior to the protocol change and 20 after. After the intervention, radiation dose, radiation per run, total exposure, and exposure per run were all significantly decreased even after adjustment for BMI (all p<0.05). On multivariable analysis, we identified a 46% decrease in total radiation dose and 39% decrease in exposure without compromising image quality or procedure time.Conclusions: We demonstrated that for routine DCAs, pulse rate of 7.5 with a frame rate of 4.0 is sufficient to obtain diagnostic information without compromising image quality or elongating procedure time. In the interest of patient, provider, and health care staff safety, we strongly encourage all interventionalists to be cognizant of radiation usage to avoid unnecessary radiation exposure and consequential health risks.