RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        Five-fold Gastrointestinal Electrical Stimulation With Electromyography-based Activity Analysis: Towards Multilocular Theranostic Intestinal Implants

        Jonas F Schiemer,Axel Heimann,Karin H Somerlik-Fuchs,Roman Ruff,Klaus-Peter Hoffmann,Jan Baumgart,Manfred Berres,Hauke Lang,Werner Kneist 대한소화기 기능성질환∙운동학회 2019 Journal of Neurogastroenterology and Motility (JNM Vol.25 No.3

        Background/AimsMotility disorders are common and may affect the entire gastrointestinal (GI) tract but current treatment is limited. Multilocularsensing of GI electrical activity and variable electrical stimulation (ES) is a promising option. The aim of our study is to investigate theeffects of adjustable ES on poststimulatory spike activities in 5 GI segments. MethodsSix acute porcine experiments were performed with direct ES by 4 ES parameter sets (30 seconds, 25 mA, 500 microseconds or1000 microseconds, 30 Hz or 130 Hz) applied through subserosal electrodes in the stomach, duodenum, ileum, jejunum, and colon. Multi-channel electromyography of baseline and post-stimulatory GI electrical activity were recorded for 3 minutes with hook needleand hook-wire electrodes. Spike activities were algorithmically calculated, visualized in a heat map, and tested for significance byPoisson analysis. ResultsPost-stimulatory spike activities were markedly increased in the stomach (7 of 24 test results), duodenum (8 of 24), jejunum (23 of24), ileum (18 of 24), and colon (5 of 24). ES parameter analysis revealed that 80.0% of the GI parts (all but duodenum) required apulse width of 1000 microseconds, and 60.0% (all but jejunum and colon) required 130 Hz frequency for maximum spike activity. Fivereaction patterns were distinguished, with 30.0% earlier responses (type I), 42.5% later or mixed type responses (type II, III, and X),and 27.5% non-significant responses (type 0). ConclusionsMultilocular ES with variable ES parameters is feasible and may significantly modulate GI electrical activity. Automatedelectromyography analysis revealed complex reaction patterns in the 5 examined GI segments.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼