Removal of Uranium from Uranium Plant Wastewater Using Zero-Valent Iron in an Ultrasonic Field
Jing Li,Libo Zhang,Jinhui Peng,Jinming Hu,Lifeng Yang,Aiyuan Ma,Hongying Xia,Wenqian Guo,Xia Yu 한국원자력학회 2016 Nuclear Engineering and Technology Vol.48 No.3
Uranium removal from uranium plant wastewater using zero-valent iron in an ultrasonicfield was investigated. Batch experiments designed by the response surface methodology(RSM) were conducted to study the effects of pH, ultrasonic reaction time, and dosage ofzero-valent iron on uranium removal efficiency. From the experimental data obtained inthis work, it was found that the ultrasonic method employing zero-valent iron powdereffectively removes uranium from uranium plant wastewater with a uranium concentrationof 2,772.23 mg/L. The pH ranges widely from 3 to 7 in the ultrasonic field, and theprediction model obtained by the RSM has good agreement with the experimental results.