http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
현옥배,김혜림,임성우,심정욱,박권배,오일성,Hyun, O.B.,Kim, H.R.,Yim, Y.S.,Sim, J.,Park, K.B.,Oh, I.S. 한국초전도학회 2008 Progress in superconductivity Vol.10 No.1
We present domestic efforts for superconducting fault current limiter (SFCL) application in the Korea Electric Power Corporation (KEPCO) grid and pending points at issue. KEPCO's decision to upgrade the 154 kV/22.9 kV main transformer from 60 MVA to 100 MVA cast a problem of high fault current in the 22.9 kV distribution lines. The grid planners supported adopting an SFCL to control the fault current. This environment friendly to SFCL application must be highly dependent upon the successful development of SFCL having specifications that domestic utility required. The required conditions are (1) small size of not greater than twice of 22.9 kV gas insulated switch-gear (GIS), (2) sustainability of current limitation without the line breaking by circuit breakers (CB) for maximum 1.5 seconds. Also, optionally, recommended is (3) the reclosing capability. Conventional resistive SFCLs do not meet (1) $\sim$ (3) all together. A hybrid SFCL is an excellent solution to meet the conditions. The hybrid SFCL consists of HTS SFCL components for fault detection and line commutation, a fast switch (FS) to break the primary path, and a limiter. This characteristic structure not only enables excellent current limiting performances and the reclosing capability, but also allows drastic reduction of HTS volume and small size of the cryostat, resulting in economic feasibility and compactness of the equipment. External current limiter also enables long term limitation since it is far less sensitive to heat generation than HTS. Semi-active operation is another advantage of the hybrid structure. We will discuss more pending points at issues such as maintenance-free long term operation, small size to accommodate the in-house substation, passive and active control, back-up plans, diagnosis, and so on.
오성용,현옥배,김찬중,Oh, S.Y.,Hyun, O.B.,Kim, Chan-Joong 한국초전도학회 2006 Progress in superconductivity Vol.7 No.2
As a material for SFCL(Superconducting Fault Current Limiter), BSCCO tube with metal stabilizer is a promising candidate, assuring the stability and large power capacity, For the application, the proper soldering technique, which overcome the difficulties of the joining between BSCCO and metal stabilizer, is required. In this study, after soldering In-Bi solder and In-Sn solder with BSCCO superconductor, welding properties between BSCCO and solders were investigated. Because ceramic materials is difficult to weld, Ag electro-plating on BSCCO 2212 is used for intermetallic layer. To find out the best welding condition for superconductor, soldering is tested in the maximum temperature from $155^{\circ}C\;to\;165^{\circ}C$ in the reflow oven. By investigating the composition and thickness of IMC (lntermetallic Compound) created in the reaction of Ag with solder, we analyzed the welding properties of High-Tc superconductor from a micro point of view.
김우석,박충렬,현옥배,김혜림,임성우,유승덕,양성은,Kim, W.S.,Park, C.R.,Hyun, O.B.,Kim, H.R.,Yim, S.W.,Yu, S.D.,Yang, S.E. 한국초전도학회 2010 Progress in superconductivity Vol.12 No.1
A double line commutation (DLC) type SFCL with first peak limiting function has been proposed for ideal fault current limiting operation. Very fast switching (commutation) without any arc or high voltage problems for any kind of switching device is needed for the first peak current limiting. We've tried to find suitable conditions for a successful switching of a Vacuum Interrupter (VI) with HTS elements as a Peak Current limiting Resistance (PCR).
YBCO 박막을 이용한 3상 6.6kV 항형 초전도 한류기의 동시Quench 분석
심정욱,김혜림,현옥배,Sim J,Kim H. R,Hyun O. B 한국초전도학회 2004 Progress in superconductivity Vol.6 No.1
We fabricated a resistive type superconducting fault current limiter (SFCL) of 3-phase $6.6 kV_{rms}$ / rating, based on YBCO thin films grown on sapphire substrates with a diameter off inch. Each element of the SFCL was designed to have the rated voltage of $600 V_{rms}$ $/35A_{rms}$. The elements produced a single phase with 8${\times}$6 components connected in series and parallel. In addition, a NiCr shunt resistor of 23 $\Omega$ was connected in parallel to each of them for simultaneous quenches between the elements. Prior to investigating the performance of the 3 phase SFCL, we examined the quench characteristics for 8 elements connected in series. For all elements, simultaneous quenches and equal voltage distribution within 10% deviation from the average were obtained. Based on these results, performance of the SFCL for single line-to-ground faults was investigated. The SFCL successfully limited the fault current of $10 kA_{ rms}$ below 816 $A_{peak}$ within 0.12 msec right after the fault occurred. During the quench process, average temperature of all components did not exceed 250 K, and the SFCL was totally safe during the whole operation.
Temperature Behavior of Superconducting Fault Current Limiters during Quenches
김혜림,심정욱,현옥배,Kim H.-R.,Sim J.,Hyun O.-B. The Korean Superconductivity Society 2005 Progress in superconductivity Vol.6 No.2
We investigated temperature behavior of superconducting fault current limiters (SFCLs) during quenches. Knowledge on temperature behavior during quenches is important to the design of SFCLs, because the temperature of SFCLs is related to their stability. SFCLs were fabricated by patterning $Au/YBa_2Cu_3O_7$ thin films grown on sapphire substrates into meander lines by photolithography. A gold film grown on the back side of the substrate was patterned into a meander line, and used as a temperature sensor. The front meander line was subjected to simulated AC fault currents, and the back line to DC current. They were immersed in liquid nitrogen during the experiment for effective cooling. Overall, temperature at the back side of SFCLs was close to that at the front side. It was closer at the beginning of faults, and at lower applied voltages. Temperature distribution at the back side was even except at the edge, as at the front side. These results tell that the whole SFCL was heated to similar degree during quenches, and that effective cooling of SFCLs at the back side is as important to the stability of SFCLs as at the front side. The results could be explained with the concept of heat transfer within the film.
복합고체절연물의 극저온 절연성능 평가를 위한 임펄스 내전압시험
김우석,유승덕,현옥배,김혜림,임성우,양성은,김희선,Kim, W.S.,Ryu, S.D.,Hyun, O.B.,Kim, H.R.,Yim, S.W.,Yang, S.E.,Kim, H.S. 한국초전도학회 2011 Progress in superconductivity Vol.13 No.1
High voltage insulation in cryogenic environment is one of big issues for development of superconducting power application, such as superconducting fault current limiter, transformer, transmission cable, and so on. We had proposed a composite solid insulator composed of plastics and polymer insulation sheets for a use of high voltage superconducting power applications. It is well known that the G10 FRP keeps its mechanical strength at very low temperature and the PPLP is very good insulator adopted as insulations for superconducting transmission cables. The composition of these two materials will show very good electrical and mechanical properties adequate for the insulation components of superconducting power applications, such as bushing, insulation barrier, and even for a cryostat. Dielectric strengths of prepared samples were measured at the temperature of boiling point of liquid nitrogen at atmospheric pressure, which will be presented in this paper to show a usefulness of this technique.
김혜림,임성우,오성용,현옥배,Kim, H.R.,Yim, S.W.,Oh, S.Y.,Hyun, O.B. 한국초전도학회 2008 Progress in superconductivity Vol.9 No.2
We investigated the size effect on quench development in $Au/YBa_2Cu_3O_7$ (YBCO) thin film meander lines on sapphire substrates. The meander lines were fabricated by patterning YBCO films coated with gold layers. The lines were subjected to simulated AC fault current, and immersed in liquid nitrogen during the experiment. After the initial rapid rise, the resistance increased moderately and then slowly. In 4 inch-diameter meander lines, the period during which the resistance increased moderately was considerably longer than in 2 inch-diameter line. Moderate increase of resistance was originated from quench propagation. The film temperature was about 180 K at the point when the propagation was completed. The rate of resistance increase after the quench completion was not affected by the film size.
Voltage Applicable to $Au/YBa_2Cu3O_7$ Meander Lines
김혜림,임성우,유승덕,박충렬,양성은,김우석,현옥배,Kim, H.R.,Yim, S.W.,Yu, S.D.,Park, C.R.,Yang, S.E.,Kim, W.S.,Hyun, O.B. The Korean Superconductivity Society 2010 Progress in superconductivity Vol.12 No.1
We investigated the voltage applicable to $Au/YBa_2Cu3O_7$ (YBCO) meander lines. The meander line was fabricated by patterning Au/YBCO thin films grown on sapphire substrates by photolithography. It was subjected to simulated AC fault currents, and the resistance was measured and analyzed. The samples were immersed in liquid nitrogen during the experiment for effective cooling. The voltage applicable to the meander lines depended on the fault duration. Dependence was strong at short fault durations, and weak at long durations. When the voltage was plotted as a function of the fault duration on a log-log scale, data fell more or less on straight lines for all meander lines. In other words, the voltage applicable to Au/YBCO meander lines on sapphire substrates was inversely proportional to $t^b$, where t is the fault duration and b ranges from 0.4 to 0.5. The results were analyzed quantitatively with the concept of heat balance. Under adiabatic condition, the voltage is to be inversely proportional to $t^{0.5}$ for all samples. Less value of b for some samples is thought to be due to cooling of the samples by liquid nitrogen.