http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
3종류의 구치부 Uprighting Spring의 초기응력분포에 관한 광탄성학적 연구
전윤식(Youn-Sic Chun) 대한치과교정학회 1994 대한치과교정학회지 Vol.24 No.3
The aim of this investigation was to identify which spring is more suitable for uprighting of the 30 degree inclined lower second molar in different situations. Between four different molar uprighting springs which were A, B, C type and T-Ioop spring, the author tested T-loop spring as a control material and the other springs were experimental group, Each spring was fabricated from .017″ X .025″ TMA wire and preactivated with 40 degree tip-back bend. Stabilizing unit included from the lower right central incisor to the lower right second premolar which were made by acrylic resin. The photoelastic overview of the lower right quadrant showed that stress concentrations were observed in its photoelastic model. The obtained results were as follows. 1. Higher concentration of compression can be seen clearly at the distal curvature than the mesial of the lower second molar when A type uprighting spring was applied, which can be used as a space regainer. 2. Higher level compression was presented at the mesial root apex area than the distal of the lower second molar in B type uprighting spring, which can be used as a space closer. 3. Areas of higher compression and tension were observed about the mesial and distal root of the lower second molar than A and B type in C type uprighting spring, which can be used as a partial space regainer.
상악전치 후방 견인시 견인 loop 후방에 부여한 gable bend 양에 따른 치아이동 양상에 관한 연구
전윤식(Youn-Sic Chun),노준(Joon Row),정상혁(Sang-Hyuk Jung),김희정(Hui-Jung Kim) 대한치과교정학회 2004 대한치과교정학회지 Vol.34 No.1
제 1소구치가 발치된 증례에서 bull loop를 견치 직푸방에 제작한 후 gable bend를 어느 정도 부여할 때 전치부의 효과적인 치축조절과 후방 이동향을 그대화 할 수 있는지를 입체적으로 확인하는 것이 본 연구의 목적이다. 제 1소구치가 제거된 상악우측 인공 치조골부에 중절치부터 제2대구치까지 실험용 치아들을 식립하였다. 그 후 bull-loop가 형성된 반쪽 호선에 10˚, 20˚, 30˚의 gable bend를 부여한 후 3전치를 후방 견인하여 발치공간을 폐쇄시켰고 이러한 실험과정을 각 군마다 3회씩 반복 실험하였다. 발치공간이 폐쇄된 후 실험전, 후의 교합방사선 사진상에 촬영된 전치부와 구치부의 시상면과 교합면 상에서의 각 군별 치아이동 양상을 일요인 분산분석(ANOVA)과 Scheffe 검정으로 평가한 결과 아래와 같은 결론을 얻었다. 1. Gable bend의 양이 증가할수록 전치부의 치축은 치체이동 양상을 보였으며 후방 이동량도 증가하였다. 2. Gable bend의 양이 증가할수록 구치부의 전방 이동량은 감소하였으나, 수직적 압하량 및 협측 이동량은 증가하였다.(p<0.001) 3. 발치공간에 인접한 견치의 원심회전과 제 2소구치의 근심회전에 의해 악궁의 조화가 이루어졌다.(p<0.001) The purpose of this experimental study was to determine appropriate magnitude of the Gable bends to produce maximum retraction of the. anterior teeth. The Calorific Machine was used to illustrate the tooth movement in three dimension. The experimental teeth except the first premolar were embedded in the artificial alveolar bone part. In a series of experiments;´ the extraction space was dosed using arch wires with bull loops into which the gable bends of 10°, 20°, 30° degrees were incorporated The experiments were repeated three times for each degree of the gable bend. Before and after the space closure, radiographs were taken in the sagittal and occlusal directions using ocelusal films. Analysis of variance and Scheffe post hoc test were used to determine significant differences among the three groups. The following results were obtained. 1. As magnitudes of the gable bends increased, more bodily anterior tooth movement was seen and the distance of retraction also increased 2. As magnitudes of the gable bends increase, the amount of posterior tooth protraction decreased while intrusive and buccal movement increased 3. The arch was coordinated by distal-in rotation of the canine and mesial-in rotation of the second premolar adjacent to the extraction space.
Cone-Beam Computed Tomogram (CBCT)과 Adjusted 2D lateral cephalogram의 계측점 차이에 관한 비교 연구
손수정,전윤식,김민지,Son, Soo-Jung,Chun, Youn-Sic,Kim, Minji 대한치과보철학회 2014 대한치과보철학회지 Vol.52 No.3
목적: 본 연구에서는 CBCT (Cone-Beam Computed Tomogram)와 100%로 확대율을 보정한 조절된 측모 두부 방사선 규격 계측 사진(Adjusted 2D Lateral Cephalogram; 이하 Adj-Ceph)의 좌표값을 비교하여 차이가 있는 계측점들의 항목을 분석하여 기존의 2D 분석법을 CBCT 분석에 적용할 수 있는지 여부를 평가해보고자 하였다. 재료 및 방법: 성인 환자 50명의 CBCT 자료 50개와, 동일 환자의 측모 두부 방사선 규격사진을 100% 확대율로 보정한 자료(Adj-Ceph) 50개를 대상으로 하여, 수평축과 수직축의 좌표를 비교하였다. 계측점들의 위치와 좌우 중첩 여부에 따라 두개골 전방에 위치한 점들(group A), 두개 중후방에 위치한 점들(group B), 좌우 양측성 점들(group C), 치아부위 계측점들(group D) 네 그룹으로 나누어 분석 하였고, 좌표값에 유의한 차이가 있는지 분석하기 위하여 paired t-test를 시행하였다. 결과: 수평축(Y축)에서는 Group B (S, Ar, Ba, PNS), Group C (Po, Or, Hinge axis, Go), Group D (U1RP, U6CP, L6CP) 등 11개의 계측점에서 유의한 차이가 있었다. 수직축(Z축)에서는 전체 계측점에서 유의한 차이가 있었다(P<.01). 좌표값의 차이 분석 결과 수평축에서는 13개의 계측점에서 1 mm 이상의 유의한 차이가 있었다. 수직축에서는 Group B의 Sella를 제외한 전체 계측점에서 1 mm 이상의 유의한 차이가 있었다. 결론: CBCT 분석 시에는 기존의 측모두부방사선 규격사진의 분석법을 그대로 사용하기에는 어려움이 있다. 3D 분석법, 또는 수평축에서 13개의 계측점들이 보정되고, 수칙축 19개가 보정된 수정된 새로운 2D 분석법이 사용되어야 한다. Purpose: This study aims to investigate if 2D analysis method is applicable to analysis of CBCT by comparing measuring points of CBCT with those of Adjusted 2D Lateral Cephalogram (Adj-Ceph) with magnification adjusted to 100% and finding out at which landmarks the difference in position appear. Materials and methods: CBCT data and Adj-Ceph (100% magnification) data from 50 adult patients have been extracted as research objects, and the horizontal (Y axis) and vertical (Z axis) coordinates of landmarks were compared. Landmarks have been categorized into 4 groups by the position and whether they are bilaterally overlapped. Paired t-test was used to compare differences between Adj-Ceph and CBCT. Results: Significant difference was found at 11 landmarks including Group B (S, Ar, Ba, PNS), Group C (Po, Or, Hinge axis, Go) and Group D (U1RP, U6CP, L6CP) in the horizontal (Y) axis while all the landmarks in vertical (Z) axis showed significant difference (P<.05). As a result of landmark difference analysis, a meaningful difference with more than 1 mm at 13 landmarks were indentifed in the horizontal axis. In the vertical axis, significant difference over 1 mm was detected from every landmark except Sella. Conclusion: Using the conventional lateral cephalometric measurements on CBCT is insufficient. A new 3D analysis or a modified 2D analysis adjusted on 19 landmarks of the vertical axis and 13 of the horizontal axis are needed when implementing CBCT diagnosis.