      • 암환자 700예의 진단 및 치료 CT 이용율과 CT 확대장치

        이귀원,박주선,한용문,윤세철,신경섭,Lee, Gui-Won,Park, Joo-Sun,Han, Yong-Moon,Yoon, Sei-Chul,Shinn, Kyung-Sub 대한방사선치료학회 1987 大韓放射線治療技術學會誌 Vol.2 No.1

        It has been evident since 1972 that computed tomography(CT) can play an important role in treatment and managment of the cancer patients as four steps; diagnosis, satging Treatment and follow-up. In this paper, we intended to investigate the availability of CT scan and treatment planning computer in 700 cancer patients who have undergone radiation therapy at the division of radiation therapy, Kangnam St. Mary's Hospital, Catholic Medical College between Mar. 1983 and Dec. 1985. The result were as follow; 1. Of 700 irradiated cancer patients, 342 patients ($48.9\%$) were performed CT scan prior to radiation therapy. 2. The distribution of lesions in 342 patients having CT scans was like this; CNS (83 of 104 patients, $79.8\%$), abdomen (44 of 76 patients, $57.9\%$), pelvis (100 of 188 patients, $53.2\%$) etc. in order. 3. The treatment planning computer were used in 280 cancer patients ($40\%$). 4. Of the 280 cancer patients using treatment planning computer, 167 patients ($59.6\%$) applied diagnostic CT scan and remaining 113 patients ($40.4\%$) were made body contour to be used for radiation therapy planning by the treatment planning computer. Authors also made some magnification devices used for small multiformat CT images to magnify into life size, consisting of overhead projector (3M) I.V. stand and mirror. These enabled us to make less errors in tracing the small-sized CT images during input of the anatomical data into the treatment planning computer.

      • 원자력을 주제로 하는 과학관 전시물에 대한 분석

        이귀원,양한준,Lee, Gui-Won,Yang, Han-Joon 대한디지털의료영상학회 2013 대한디지털의료영상학회논문지 Vol.15 No.2

        The purpose of this study was to provide information about exhibits for nuclear energy in science museums. This analysed form and content of exhibits of science museums. The subjects were exhibits of 3 science museums; Seoul science park, Seoul national science museum, Gwachen national science museum. The research results were as follows: First, 3 science museums had similar methods of exhibits and types of explanations because of speciality of theme. 3 science museums had mostly fixed exhibit. Panel was the most types of explanations in 3 science museums. Second, 3 science museums had similar contents of exhibits. They dealt with nuclear power generation and radiation. However, Some parts such as radioactive waste, nuclear fusion generation had different. This study suggests that exhibits for nuclear energy of science museums use a variety of methods and types of explanation. Also, science museums need to increase exhibits for nuclear energy.

      • KCI등재

        원격의료정보 시스템의 활성화 방안에 관한 연구

        이귀원(Gui Won Lee) 대한방사선과학회(구 대한방사선기술학회) 2003 방사선기술과학 Vol.26 No.4

        최근 의료시설이 취약한 1, 2차 진료기관에서 인터넷을 이용하여 원격의료정보시스템이 갖추어진 3차 진료기관에 환자의 진료예약 신청을 하고 환자가 3차 진료기관에 도착 즉시 바로 진료를 받을 수 있는 광역의료정보 시스템의 도입을 추진하고자 하는 병원들이 많아지고 있다. 본 연구에서는 원격의료정보 시스템에 대한 이론적 고찰을 하였고, 특히 신기술 분야에 대한 연구를 통하여 원격의료정보 공유시스템의 활성화 방안을 제시하고자 하였다. 원격의료정보 공유시스템의 확산을 위해서는 의료정보의 Bottom-up 방식의 도입과 종합적인 추진체계의 확립, 적극적인 인센티브제의 도입이 필요하고 관련 법*제도의 정비 및 중앙정부와의 긴밀한 협조와 연계, 기술변화에 대한 신축적 대응이 선결과제이며 적극적인 홍보와 교육이 절실히 요구된다. This system Will allow primary and secondary treatment institutions poorly equipped with medical equipment to use Internet and book their patients' medical checkups with tertiary hospitals equipped with remote medical information system. This research aims to make theoretical studies on the remote medical service information sharing system and discuss its utility and factors to be considered for spreading the system. To efficiently push ahead with the remote medocal srevice information sharing system, we need to be open-minded in sharing medical sevice information, establish comprehensive pursuit system, introduce incentive aimed at activating the information system, have close coordination with the central government, flexibly respond to changing technologies, and offer publicity and education.

      • KCI등재후보

        고용량 방사성옥소(I-131) 치료환자의 피폭선량 저감화 연구

        이귀원(Gui-Won Lee) 대한방사선과학회(구 대한방사선기술학회) 2007 방사선기술과학 Vol.30 No.4

          방사성옥소(I-131)를 이용한 갑상선 질환치료는 꾸준히 증가하고 있다. 이에 따라 치료병실을 이용해야 하는 고용량 방사성옥소치료 환자의 가파른 증가는 치료병실의 증설과 방사성목소의 이용량을 급속히 증가시키고 있다. 따라서 방사선 피폭선량에 대한 관심도 높아지고 있다.<BR>  본 연구는 환자의 심적인 부담과 환자 주변의 일반인에 대한 방사선 피폭을 최대한 줄이기 위해 퇴원시 방사선량률을 낮추고자 노력하였다. 고용량 방사성옥소치료에 따른 여러 연구 결과들을 종합적으로 분석해 보면, 치료환자에 대한 퇴원은 환자의 주변환경과 관련한 많은 인자들을 고려한 개별근거로 결정해야 하고, 퇴원시 방사선량률을 최대한 낮추는 것이 가장 좋은 방법이 될 것이다. 이것은 환자의 상태에 따라 충분하고 적절한 수분섭취에 대한 교육과 실행을 통하여 방사선량률을 낮출 수 있으며 아울러 수액을 병행하여 사용하므로서 편차가 거의 없는 방사선량률의 감쇠곡선을 얻을 수 있었다. 이러한 방법들을 통하여 같은 격리기간에도 퇴원시의 방사선량률을 크게 낮출 수 있으며, 경우에 따라서는 격리기간을 단축할 수도 있다는 것을 확인할 수 있었다. 본 연구는 실제 방사성옥소를 투여하는 환자를 대상으로 하였기 때문에 각 연구대상의 경우 수에 대한 한계를 벗어날 수 없었다. 하지만 환자상태에 맞는 충분한 수분섭취와 수액공급은 확실히 방사선량률에 영향을 주고 있다고 할 수 있다. 앞으로 장기적으로 조사관찰이 필요하며, 치료용량에 따른 여러 환자군에 대한 계속적인 연구가 이루어져야 할 것이다.   The number of thyroid diseases treated with radioiodine(I-131) is increasing steadily. The sharp increase in patients who require high dose radioiodine therapy greatly increased the need for new therapy rooms. Accordingly, interest in radiation exposure is rising as well, and is a major psychological stress factor for the patient and those who come in close contact with the patient. This study aimed to minimize the radiation exposure on discharge. Based on various previous reports, the decision for discharge should be individualized depending on many factors related to the patient"s living or working environment. Educating patients repeatedly on the importance of sufficient oral hydration, while the adequate amount was relative to the patient"s individual condition, greatly lowered the detected radiation measurement within the same admission period. In some cases, the period of admission could be abbreviated.

      • 치료계획용 콤퓨터를 이용한 부정형 조사면의 선량분포에 관한 실험

        박주선,이귀원,한용문,권형철,윤세철,Park, Joo-Sun,Lee, Gui-Won,Han, Yong-Moon,Kwon, Hyoung-Cheol,Yoon, Sei-Chul 대한방사선치료학회 1987 大韓放射線治療技術學會誌 Vol.2 No.1

        The authors have intended to measure intrinsic dose distribution by Farmer dosimeter in irregularly shaped fields such as L, M, T,-shape model in order to determine dose inhomogeneity in those models. We made 2 off-axis points in each model and measured the depth dose at 1.5,5, and 9cm below surface. The results showed $1-3\%$ dose discrepancy between 2 points. We also measured the depth dose by geometric approximation and computer calculation in those models, and came to the conclusion that computer calculation using Clarkson's principle is simpler and the measurements are to the ideal data obtained by the experiment in those three models of irregularly shaped fields than those of geometric approximation method.

      • Near Miss 사고 예방 활동과 환자안전관리 문화형성이 환자안전에 미치는 영향

        장호석,이귀원,Chang, Ho-Suk,Lee, Gui-Won 대한핵의학기술학회 2010 핵의학 기술 Vol.14 No.2

        급변하는 의료환경 속에서도 변함없이 의료기관들은 환자 안전관리 부분의 중요성을 인식하여 관리하고 있다. 하지만 현재 환자안전관리는 사후관리와 처벌이 강조된 프로세스들로 조직원들의 참여성이 결여된 문제를 보이고 있다. 본원 핵의학과 에서는 참여형 니어미스 사고예방 활동을 시행하여 환자안전사고에 사전관리를 시작하고 사고보고에 따른 불이익이 없는 시스템을 구축하여 니어미스 감소 와 환자안전사고 제로화를 목적으로 본 연구을 시작하였다. 또한 핵의학과만의 차별화된 환자안전관리System구축도 그 목적으로 하고 있다. 1. 팀원들의 과거 니어미스 및 현재 발생되고 있는 니어미스와 사고 사례수집(1차 자료수집). 2. 설문을 통해 중요도, 긴급도를 파악하고 니어미스 및 사고사례를 정량화(2차 자료수집). 3. 자료 분석을 통한 중요 접점 파악과 사고 사례 정량화. 4. 중요 접점 부분에 대한 매뉴얼 제작과 표준화, 오류방지를 위한 참여형 개선활동 시행. 5. 니어미스 보고체계 구축을 위한 웹 기반 커뮤니티 활동. 6. 설문과 FGI를 통해 활동 전후 평가 시행. 1) 비계량적이었던 핵의학과 내 안전사고 및 니어미스를 계량화(월 50여 회의 니어미스와 년 1건의 안전사고발생) 2) 계량화된 데이터를 통해 개선방안을 수립(0여건의 참여형 개선활동, 프로세스 개선, 표준화를 위한 약속 매뉴얼 제작) 3) 안전문화 시스템을 형성하고 팀원들의 높은 관여도를 형성.(보고체계구축, 체크리스트 제작, 안전문화 슬로건 제작, 평가 인덱스 구축) 4) 니어미스 및 사고 사례를 공유하고 반면교사로 삼기 위한 커뮤니티 개설. 5) 활동 전후 니어미스 발생률은 50% 감소 하였고 안전사고 제로. 핵의학과의 최고의 서비스는 환자안전이 보장된 양질의 검사와 치료를 제공하는 것이다. 참여형 개선활동으로 니어미스사고를 예방하고 안전문화를 형성하여 시스템을 구축함으로써 니어미스 발생 사례는 50% 줄었으며 안전사고는 발생하지 않았다. 이는 환자안전사고의 사전관리란 측면에서도 시사하는 바가 있다. 또한 불이익이 없는 사고보고체계도 마련하여 솔직하게 보고하고 인정하는 문화도 만든 계기가 되었다. 기본에 충실한 뛰어난 시스템은 환자에게 제공되는 최고의 서비스이며 형성된 안전문화 시스템은 결국 고객만족으로 이어질 것이다. 따라서 본원 핵의학과 에서는 마련된 시스템을 정착하고 안정시켜 차별화된 환자안전문화를 형성해 나가고자 한다. Purpose: Despite the rapidly changing healthcare environment, healthcare organizations have recognized the importance of patient safety management. But patient safety management has the problem of the lack of participation of members due to the process of focusing on the follow-up service and punishment. The department of nuclear medicine in Uijeongbu St. Mary's Hospital started this research to reduce the near miss and prevent patient safety accidents by both initiating the participatory near-miss-proof activities as an advance management and constructing a system without disadvantages of reporting. In addition, this research aims to establish a differentiated patient safety management system in the department of nuclear medicine. Materials and Methods: 1. Colleting cases of team members' past and present near miss and accidents(First data collection). 2. Quantifying the cases of near miss and accidents after identifying the degree of importance and urgency through surveys(Second data collection). 3. Quantifying cases and indentifying important points of contact through data analysis. 4. Making and standardizing a manual for important points of contact, and initiating participatory activities to prevent errors. 5. Activating web-based community for establishing the report system of near miss. 6. Estimating the result of before and after activities through surveys and focus group interviews. Results: 1) Quantified safety accidents and near miss in the department of nuclear medicine. About 50 near misses a month and one safety accident a year. 2) Establishing improvement measurements based on quantified data. About 11 participatory activities, the improvement of process, a manual for standardization. 3) Creating a system of safety culture and high participation rate of team members. Constructing a report system, making a check list and a slogan for safety culture, and establishing assessment index. 4) Activating communities for sharing the information of cases of near misses and accidents. 5) As the result of activities, the rate of near miss occurrence declined by 50% and the safety accident did not happen. Conclusion: The best service in the department of nuclear medicine is to provide patients with safety-guaranteed high-quality examination and cure. This research started from the question, 'what is the most faithful-to-the-basics way to provide the best service for patients?' and team members' common answer for this question was building a system with participation of all members. Building a system through the participatory improvement activities for preventing near miss and creating safety culture resulted in the 50% decline of near miss occurrence and no accident. This is a meaningful result from the perspective of advance management for patient safety. Moreover, this research paved the way for creating a culture to report and admit near miss or accidents by establishing a report system with no disadvantage of reporting. The system which sticks to the basics is the best service for patients and will form a patient safety culture system, which will lead to the customer satisfaction. Therefore, all members of the department of nuclear medicine will develop a differentiated patient safety culture with stabilizing the established system.

      • Analysis of the Dose Distribution of Moving Organ using a Moving Phantom System

        김연래,박병문,배용기,강민영,이귀원,방동완,Kim, Yon-Lae,Park, Byung-Moon,Bae, Yong-Ki,Kang, Min-Young,Lee, Gui-Won,Bang, Dong-Wan Korean Society for Radiation Therapy 2006 대한방사선치료학회지 Vol.18 No.2

        Purpose: Few researches have been peformed on the dose distribution of the moving organ for radiotherapy so far. In order to simulate the organ motion caused by respiratory function, multipurpose phantom and moving device was used and dosimetric measurements for dose distribution of the moving organs were conducted in this study. The purpose of our study was to evaluate how dose distributions are changed due to respiratory motion. Materials and Methods: A multipurpose phantom and a moving device were developed for the measurement of the dose distribution of the moving organ due to respiratory function. Acryl chosen design of the phantom was considered the most obvious choice for phantom material. For construction of the phantom, we used acryl and cork with density of $1.14g/cm^3,\;0.32g/cm^3$ respectively. Acryl and cork slab in the phantom were used to simulate the normal organ and lung respectively. The moving phantom system was composed of moving device, moving control system, and acryl and cork phantom. Gafchromic film and EDR2 film were used to measure dose ditrbutions. The moving device system may be driven by two directional step motors and able to perform 2 dimensional movements (x, z axis), but only 1 dimensional movement(z axis) was used for this study. Results: Larger penumbra was shown in the cork phantom than in the acryl phantom. The dose profile and isodose curve of Gafchromic EBT film were not uniform since the film has small optical density responding to the dose. As the organ motion was increased, the blurrings in penumbra, flatness, and symmetry were increased. Most of measurements of dose distrbutions, Gafchromic EBT film has poor flatness and symmetry than EDR2 film, but both penumbra distributions were more or less comparable. Conclusion: The Gafchromic EBT film is more useful as it does not need development and more radiation dose could be exposed than EDR2 film without losing film characteristics. But as response of the optical density of Gafchromic EBT film to dose is low, beam profiles have more fluctuation at Gafchromic EBT. If the multipurpose phantom and moving device are used for treatment Q.A, and its corrections are made, treatment quality should be improved for the moving organs.

      • 체내대사를 이용한 핵의학적 검사의 선량률 저감에 관한 연구

        강용길,나수경,홍진웅,이귀원,김낙상,Kang, Yong-Gil,Na, Soo-Kyung,Hong, Jin-Woong,Lee, Gui-Won,Kim, Nak-Sang 대한디지털의료영상학회 2012 대한디지털의료영상학회논문지 Vol.14 No.2

        The purpose of this study was administered to the body for examination and treatment, high-energy radioactive isotope(F-18, I-131) in vitro discharge experiments. Increasing exposed dose of radiation to health professionals is caused by the increase of PET/CT use and a radioactive isotope. Therefore, the high-energy isotope F-18 and I-131 after administration about using Metabolite excretion was studied. As a results of this study, patients had plenty of fluids for testing and treatment alone administered radiopharmaceuticals can be more than twice as fast excretion induced emissions. Also was able to get a better image space to reduce the dose rate.

      • 핵의학과 내에서의 효과적인 고객위험관리: 위험관리 응대 MOT 개발적용 및 홍보동영상 제작

        함종훈,황재봉,김준호,이귀원,Ham, Jong-Hum,Hwang, Jae-Bong,Kim, Joon-Ho,Lee, Gui-Won 대한핵의학기술학회 2009 핵의학 기술 Vol.13 No.3

        목적: 최근 의료기관평가제도는 의료의 질에 대한 병원들의 관심을 높게 하고 그것을 향상시키기 위한 활동을 활발히 전개하고 있다. 또한 추가된 항목인 환자의 위험관리에 대해서도 많은 관심을 보이고 있다. 의정부성모병원 핵의학과는 2008년도 PET/CT도입으로 시작된 부서내 리모델링은 과내 구조 및 업무 프로세스에 많은 변화를 가져왔다. 따라서 변경된 구조와 기존의 업무 처리방식은 미처 알지 못하는 위험요인을 내포하게 되었다. 그러므로 영상 검사 과정에서 발생할 수 있는 위험요인을 다각도로 찾고 분석하여, 부서의 특수한 환경에 맞는 위험관리 프로세스와 위험요인 제거업무를 포함한 개선 활동을 목적으로 한다. 실험재료 및 방법: 핵의학과의 새로워진 프로세스를 다각도로 분석하여 첫째, 위험관리 응대메뉴얼을 제작하여 교육후 실제 업무에 적용한다. 결과분석은 전년도 위험사고 발생건수와 개선활동 후 위험사고 발생건수를 비교하였다. 둘째, 위험관리 홍보동영상은 제작 후 검사전 해당 환자에게 상영하였고 그 후 자체 제작된 설문지로 해당 환자 100명에게 만족도 조사를 하였다. 셋째, 위험요소를 개선할 수 있는 시설물 참여형 개선활동을 통해서 위험요소를 제거하였다. 결과: 안전사고 발생건수는 개선활동이후 PET/CT와 감마카메라 영상 검사 모두 검사건수대비 투약오류, 낙상, 충돌 등의 안전사고가 0건으로 조사되었다. 설문조사 결과는 동영상 상영 후 검사진행과정 이해 74%, 불안감해소 81%로 "만족한다"는 결과가 조사되었다. "위험요소에 대해 주의했습니까?" 라는 물음의 경우 PET/CT는 94%, 감마카메라는 89%가 주의했다는 결과로 조사되었다. 개선활동을 통해서 핵의학과내에서의 고객위험관리를 효과적으로 수행할 수 있었다. 결론: 본 개선활동을 통하여 영상 검사 시 산재된 위험요소를 체계적으로 나열하고 분석하는 계기가 되었다. 또한 안전사고에 대처하는 방사선사의 업무방법에서도 기준이 되는 응대메뉴얼을 적용시킨다면 안전사고의 최소화와 안전사고시 체계적인 피드백이 가능함을 알 수 있었다. 위험요소를 알려주는 방법론적인 부분에서도 일상생활에서 쉽게 접할 수 있는 시청각자료로 제공 되었을 때 보다 효과적이였다. 따라서 이런 활동이 지속적이고 세부화 된 업그레이드 작업을 통해서 환자들에게 제작되어 제공된다면 핵의학 검사 이용의 안전성과 편리성에 도움을 줄 수 있으리라 생각된다. Purpose: Nowadays, A medical institution assesment could get more interest about a quality of medical services from many hospitals that developed the active activities for improving medical services. Also, there is an other additional issue which is the patients risk management. Uijeongbu ST. Mary's hospital Nuclear Medicine department has been changed many work process after PET-CT introduction and renovation of its place since 2008. Therefore, modified structure and the way of existing work process have contained risk factors. The purpose of this study would be the appropriate risk management process while imaging examination process, the removal risk factors and improved activities through the analysis risk factors. Materials and Methods: Nuclear Medicine department new process should analysis through many-sided, Firstly, make and trained risk management manual after then apply an actual work. Result analysis showed the number of risk accident occurrence that comparing the last year and after the improved activities. Secondly, producing risk management public relations film has been showed an applicable patient after then the customer service measurement checked for a hundred patient by questionnaire. Lastly, Risk factors were eliminated through the facilities participation improving activities which could change for the better risk factors. Results: The number of safety accident occurrence(medication error, fall and collision) were checked as zero after the improving activities both PET-CT and gamma camera examination. The results of questionnaire showed as follows; 74% marked as understanding of the test process and 81% checked "satisfaction" after the public relations film showing. The question "Did you consider about the risk factors?", both PET-CT and gamma camera checked as 94% and 89% respectively. Customer risk management could be accomplished effectively through the improving activities at the nuclear medicine department. Conclusions: The study would be an opportunity that spread risk factors were systematically showed and analyzied. Also, It showed the possibility of the minimized safety accident and its feedback, if application of the response manuel that could be a standard of radiology technician's work method to react safety accident. It was the more effective that visual material could be easy to approach as a methodology of risk factors. As far as I have concerned that It could help the safety and convenience through continuous and detailed activities that offer to patients.

      • KCI등재후보

        선형가속기를 기반으로 한 뇌정위 방사선 수술 시 전용 콘과 정방형 소조사면의 선량 특성에 관한 고찰

        윤준(Joon Yoon),이귀원(Gui-Won Lee),박병문(Byung-Moon Park) 대한방사선과학회(구 대한방사선기술학회) 2010 방사선기술과학 Vol.33 No.1

        선형가속기를 기반으로 하는 뇌정위적 방사선 수술에 있어 전용 콘과 동일한 정방형 조사면에서의 소조사면 선량특성에 관해 알아보고자 6 MV 광자선과 소조사면 전용 검출기를 이용해 측정하였다. 선원 표면간 거리는 100 cm로 하고, 전용 cone Φ1 cm, Φ2 cm, Φ3 cm과 정방형 조사면 1×1 cm2, 2×2 cm2, 3×3 cm2 조사면 으로 1.5 cm, 5 cm, 10 cm, 20 cm, 30 cm 지점에서 심부선량을 측정하였고, 최대 선량점에서 각 조사면에서 출력선량을 측정하여 비교하였다. 반음영의 측정을 위한 선량측면도 측정은 Φ1 cm, Φ3 cm 및 동일한 정방형 조사면에서 선원 표면간 거리 95 cm, 깊이 5 cm에서 SFD를 이용하여 측정하였다. 물리학적 조사면(90%) 내에서는 1 mm 간격으로, 반음영 영역(20~80%)에서는 0.5 mm 간격으로 측정하였다. 전용 콘 과 정방향 조사면의 PDD 변화는 기준조사면을 기준으로 5 cm 깊이에서 4.3~7.9% 낮게 나타났으며, 콘의 크기와 조사면 크기가 커질수록 PDD 변화는 적게 나타났다. 선질 비교를 위해 PDD20,10를 비교한 결과 Φ1 cm 콘과 1×1 cm2을 제외한 다른 조사면에서는 1% 이내의 변화를 보였다. 출력선량은 콘을 이용한 방법에서 정방형 조사면에서 보다 3.1~4.6% 출력선량이 증가하였다. 반음영 영역은 Φ1 cm, Φ3 cm 동일한 정방형 조사면에서 콘을 이용한 방법이 반음영 영역이 20% 감소하였다. 뇌정위적 방사선 수술은 소조사면을 이용해 1회 대선량을 조사하는 방법으로 소조사면의 선량특성을 고려한 처방이 중요하게 된다. 본 실험을 통해 뇌정위적 방사선 수술에 있어 정방형 소조사면 보다 전용 콘을 이용한 방법이 유효하다고 사료되며, 향후 다양한 측정기를 이용한 소조사면의 선량특성에 관한 연구가 필요하다고 생각된다. In this paper we evaluated small field dose characteristics of exclusive cone fields versus square fields for stereotactic radiosugery (SRS) which is based on linear accelerators (LINAC). For this test, we used a small beam detector (stereotactic fields detector : SFD) with a 6 MV photon beam and a water phantom system (IBA, Germany). Percentage depth dose (PDD) was measured for different field sets (cones : Φ1 cm, Φ2cm, Φ3 cm ; square fields : 1×1 cm2, 2×2 cm2, 3×3 cm2) at a source skin distance (SSD) of 100 cm. We measured the point depths at 1.5 cm, 5 cm, 10 cm, 20 cm, and 30 cm. The output factors were measured under the same geometrical conditions of the PDD and normalized at the maximum dose depth. To analyze the penumbra, we measured the dose profile with 95 cm of SSD, 5 cm of depth for each field sizes (Φ1 cm,Φ3 cm, 1×1 cm2, and 3×3 cm2) using SFD. We obtained the values for every 1 mm interval in the physical field (90%) and 0.5 mm interval in the penumbra region (20 to 80%). The PDD variation of exclusive cones and square fields were 4.3 to 7.9% lesser than the standard field size (10×10 cm2). The variation of PDD was reduced while the field size was increased. To compare the beam quality, we analyzed the PDD20,10 and the results showed under the 1% of variations for all experiments except for Φ1 cm cone and 1×1㎠ fields. Output factors of exclusive cone were increased 3.1~4.6% than the square fields, and the penumbra region of exclusive cone was reduced 20% as compared to the square fields. As the previous researches report, it is very important for SRS and SFD that precise dosimetry in small beam fields. In this paper, we showed the effectiveness of exclusive cone, compared to square field. And we will study on the various detector characteritstics for small beam fields.