http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
765 kV 송전선로 보호를 위한 아크사고 시뮬레이션 및 적응적 자동재폐로 대책
안상필,김철환,Ahn, Sang-Pil,Kim, Chull-Hwan 대한전기학회 1999 전기학회논문지A Vol.48 No.11
In many countries including Korea, in order to transmit the more electric power, the higher transmission line voltage is inevitable. So, a rapid reclosing scheme is important for EHV/UHV transmission lines to ensure requirements for high reliability of main lines. A critical aspect of reclosing operation is the extinction of the secondary arc since it must extinguish before successful reclosure can occur. Therefore the accurate simulation techniques of arcing faults are of importance. And successful reclosing switching can be accomplished by adopting a proper method such as HSGS and hybrid scheme to reduce the secondary arc extinction time. First of all, this paper discusses a suggested arc model, which have time dependent resistance for primary arc and piecewise linear approximated arc model for secondary arc. And this simulation technique is applied to Korean 765 kV transmission lines. Also hybrid scheme is simulated and evaluated for the purpose of shortening dead time. For adaptive reclosing scheme, variable dead time control algorithm is suggested. Two kinds of algorithm are tested. One is max tracking algorithm and the other is rms tracking algorithm. According to simulation results, rms tracking has less errors than max tracking. Therefore rms tracking is applied to Korean 765 kV transmission lines with hybrid scheme.
안상필(Sang-Pil AHN),김언석(Oun-Seok KIM),류재남(Jae-Nam RYU) 한국조명·전기설비학회 2010 한국조명·전기설비학회 학술대회논문집 Vol.2010 No.9월
Recently many countries including. Korea has been developing Electric Vehicles(EV) and Plug-in Hybrid EV(PHEV). For this purpose, it is necessary to analyse the trend of standardization for the accessories, which are used for charging EV or PHEV, such as connector, inlet, plug, socket-outlet. Therefore this paper gives an information for domestic and int'l trend for those standards for contributing related industries.
안상필(AHN Sang-Pil),류재남(RYU Jae-Nam),김철환(KIM Chul-Hwan) 대한전기학회 2006 대한전기학회 학술대회 논문집 Vol.2006 No.7
최근 저압 기중차단기(ACB, Air Circuit Breaker)는 고압중전기 공인시험제도 및 저압전기기기 안전인증제도와 같은 강제인증 대상에서 제외되어 해당 성능에 대한 안전 사각지대에 놓여있다는 지적을 받아왔다. 본 논문에서는 현재의 ACB관련 규격 및 성능평가기술을 분석하고, 국제규격과의 비교 분석을 통하여 국제규격에 준하는 성능평가기술 및 규격을 제시하는 방안을 연구하였다. 특히 내년에 제정이 논의되고 있는 ACB관련 KS 규격의 제정 방향 및 KS 심사기준에 대한 진행방향 설정과 연구되어야할 성능평가기술을 제품성능 특성별로 제시하였다. 향후 본 논문의 성능 평가기술 및 제안 방향이 KS규격 제정 및 활용에 중요한 근간을 제공할 것으로 기대한다.
안상필(Sang-Pil AHN),류재남(Jae-Nam RYU) 대한전기학회 2009 대한전기학회 학술대회 논문집 Vol.2009 No.7
본 논문에서는 최근 안전에 논란이 되어 2008년 안전기준이 제정된 자동복귀(복구, 재폐로) 누전차단기에 대한 표준화 동향을 정리하고 추후 제도적 안정과 대민안전을 위한 발전방향을 제시하였다.