칼날 주사방식을 이용한 중적외선 렌즈의 변조전달함수 측정 장치
송세용,조재흥,홍성목,이회윤,이윤우,Song, Se-Yong,Jo, Jae-Heung,Hong, Sung-Mok,Lee, Hoi-Youn,Lee, Yun-Woo 한국광학회 2011 한국광학회지 Vol.22 No.1
We fabricate a measuring system to measure the modulation transfer function (MTF) of a mid-infrared imaging silicon lens by using the knife-edge scanning technique. In particular, we measure on-axial tangential MTF of the silicon lens with the focal length of 50 mm and F-number F/4 in the wavelength band of mid-infrared between $3\;{\mu}m$ and $5\;{\mu}m$. In order to obtain the infinite object, the off-axial parabolic reflector with the focal length of 2.545 m is utilized. In the comparison with measured MTF data and designed MTF values curve, we find that the tolerance of measured MTF data below the spatial frequency of 7 lp/mm is within 2%. 중적외선 결상용 실리콘 렌즈의 변조전달함수(MTF)를 칼날 주사방식으로 측정하는 적외선 MTF 측정장치를 구성하였다. 이를 위하여 반달형 칼날 물체를 사용하여 초점거리 50 mm, F/4인 실리콘 렌즈에 대한 중적외선 파장대인 $3{\sim}5\;{\mu}m$에서의 축상 자오 방향에 대한 MTF를 측정하였다. 이 때 무한 물체를 만들기 위해서 초점거리가 2.545 m인 비축 포물 반사경을 사용하였다. 측정한 MTF는 렌즈의 설계 자료로부터 구한 MTF와 비교한 결과, 7 lp/mm 이하에서 2 % 이내의 MTF 허용오차를 만족하고 있음을 알 수 있었다.
족관절 체중 부하 중립위에서 배굴 상태 변화에 따른 정상 원위 경비 결합의 방사선학적 측정
신성기 ( Seong Kee Shin ),김기천 ( Ki Chun Kim ),송세용 ( Se Yong Song ),양기원 ( Ki Won Young ),이경태 ( Kyung Tai Lee ) 대한스포츠의학회 2021 대한스포츠의학회지 Vol.39 No.1
Purpose: Reliable landmarks of ankle syndesmosis change in various positions is important for managing ankle injury. The purpose of our study was to investigate and compare radiographic landmarks of normal ankle in various positions. Methods: The study involved both ankle radiographs of 30 subjects (15 males, 15 females) without clinical or radiographic abnormality. Tibiofibular clear space (TFCS) and tibiofibular overlap (TFO) were measured on anteroposterior (AP) and mortise radiographs in non-standing (NS) and standing (S) neutral and dorsiflexion 10° (DF10) and 20° (DF20). The radiographic measurements were used to calculate means, standard deviations, and intra- and interobserver reliabilities, and compare TFCS and TFO in various positions and genders. Results: On the AP view, the mean TFCS in NS, S, DF10, and DF20 positions were 4.00±0.97, 4.00±0.83, 4.35±0.95, and 4.45±0.89 mm and the mean TFO on the same positions were 6.58±2.27, 4.27±1.90, 3.44±1.96, and 2.38±1.91 mm. On the mortise view, the mean TFCS in NS, DF10, and DF20 positions were 3.62±0.88, 4.08±0.86, and 3.88±0.97 mm and the mean TFO on the same positions were 3.57±2.13, 2.31±1.77, and 3.57±2.14 mm. The reliabilities in all positions except TFCS on some positions were excellent. No measurement was significantly different between females and males except TFO in NS on mortise view (p=0.006) and DF10 on AP view (p=0.032). Conclusion: Increase of TFCS and decrease of TFO on AP view reflects syndesmosis change from NS to DF20 on standing. Clinically, the effect of weight-bearing and reliability of TFO should be considered.