http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
3변수 및 4변수 Kappa 분포에 의한 설계홍수량 추정
맹승진,김병준,김형산,Maeng, Seung-Jin,Kim, Byeoung-Jun,Kim, Hyung-San 한국농공학회 2009 한국농공학회논문집 Vol.51 No.4
This paper is to induce design floods through L-moment with 3 and 4 parameter Kappa distributions including test of independence by Wald-Wolfowitz, homogeneity by Mann-Whitney and outlier by Grubbs-Beck on annual maximum flood flows at 9 water level gaging stations in Han, Nakdong and Geum Rivers of South Korea. After analyzing appropriateness of the data of annual maximum flood flows by Kolmogorov-Smirnov test, 3 and 4 Kappa distributions were applied and the appropriateness was judged. The parameters of 3 and 4 Kappa distributions were estimated by L-moment method and the design floods by water level gaging station was calculated. Through the comparative analysis using the relative root mean square errors (RRMSE) and relative absolute errors (RAE) calculated by 3 and 4 parameter Kappa distributions with 4 plotting position formulas, the result showed that the design floods by 4 parameter Kappa distribution with Weibull and Cunnane plotting position formulas are closer to the observed data than those obtained by 3 parameter Kappa distribution with 4 plotting position formulas and 4 parameter Kappa distribution with Hazen and Gringorten plotting position formulas.
Wakeby 및 Kappa 분포의 L-모멘트법에 의한 홍수빈도분석
맹승진,이순혁,이현규,류경식,송기현,Maeng, Seung-Jin,Lee, Soon-Hyuk,Lee, Hyeon-Gyu,Ryu, Kyong-Sik,Song, Gi-Heon 한국농공학회 2006 한국농공학회논문집 Vol.48 No.5
The objective of this study is to induce the design floods by the methodology of L-moment including test of homogeneity, independence and outlier of the data of annual maximum flood flows for 12 water level gaging stations of South Korea. To select appropriate distribution of the data for annual maximum flood flows, the distributions of Wakeby and Kappa are applied and the appropriateness is judged by Kolmogorov-smirnov (K-S) test. The parameters of selected Wakeby and Kappa distributions are calculated by the method of L-moment and the design floods are induced. Through the comparative analysis using the relative root mean square errors (RRMSE) and relative absolute errors (RAE) of design floods, the result shows that the design floods by Wakeby distribution are closer to the observed data than those obtained by the Kappa distribution.
맹승진,이배성,Maeng, Seung-Jin,Lee, Bae-Seong 한국농공학회 2007 한국농공학회논문집 Vol.49 No.5
In this study, we reviewed the optimal space for the fishway and fish storage establishment in the section between the downstream of the Hwacheon dam and the confluence of the Pungsan river. The hydraulic stability of these facilities was also examined. In the section between the downstream of Hwacheon dam and the confluence of Pungsan river, the release flow of Hwacheon dam was set at $5,495m^3/s,\;6,110m^3/s$ and $7,537m^3/s$, and numerical simulations were executed for each instance using the HEC-RAS model and RMA-2. In the analysis of the flow velocity distributions in the subject section by release flows of Hwacheon dam, it was shown that there was over 5.0m/s of high flow velocity at Sta. $#1{\sim}Sta.$ #3, Sta. $#4{\sim}Sta.$ #6, and Sta. $#12{\sim}Sta.$ #13 of the sections analyzed in this study. The Sta. $#0{\sim}Sta.$ #1 was considered appropriate for the fishway and fish storage establishment. As seen in the results of the numerical stability review by release flow conditions of Hwacheon dam subject to the selected available areas fur fishway and fish storage, the topographically available section for the establishment of fishway and fish storage exists at Sta. $#1{\sim}Sta.$ #3 when the release flow of Hwacheon dam is $5,495m^3/s$, whereas Sta. $#0{\sim}Sta.$ #1 should be reviewed for the subject section for the establishment of fishway at release flows of $6,110m^3/s$ and $7,537m^3/s$, in addition to the figures gathered at the $5,495m^3/s$ release flow. Finally, the available section for the establishment of fishway and fish storage was determined to be Sta. $#0{\sim}Sta.$ #3. Further, if fishway and fish storage are established in the outer bank within this section, the high flow velocity section should be avoided. An alternative would be to establish for the fishway in the inner band on the section of Sta. #1 or Sta. #3.