RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
          펼치기
        • 등재정보
        • 학술지명
          펼치기
        • 주제분류
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        수중 플라즈마 공정을 이용한 Rhodamine B 염료의 제거

        김동석,박영식,Kim, Dong-Seog,Park, Young-Seek 한국환경보건학회 2011 한국환경보건학회지 Vol.37 No.3

        Objectives: In this paper, a dielectric barrier discharge (DBD) plasma reactor was investigated for degrading the dye Rhodamine B (RhB) in aqueous solutions. Methods: The DBD plasma reactor system in this study consisted of a plasma component [titanium discharge (inner), ground (outer) electrode and quartz dielectric tube], power source, and gas supply. The effects of various parameters such as first voltage (input power), gas flow rate, second voltage (output power), conductivity and pH were investigated. Results: Experimental results showed that a 99% aqueous solution of 20 mg/l Rhodamine B is decolorized following an eleven minute plasma treatment. When comparing the performance of electrolysis and plasma treatment, the RhB degradation of the plasma process was higher that of the electrolysis. The optimum first voltage and air flow rate were 160 V (voltage of trans is 15 kV) and 3 l/min, respectively. With increased second voltage (4 kV to 15 kV), RhB degradation was increased. The higher the pH and the lower conductivity, the more Rhodamine B degradation was observed. Conclusions: OH radical generation of dielectric plasma process was identified by degradation of N, N-dimethyl-4-nitrosoaniline (RNO, indicator of OH radical generation). It was observed that the effect of UV light, which was generated as streamer discharge, on Rhodamine B degradation was not high. Rhodamine B removal was influenced by real second voltage regardless of initial first and second voltage. The effects of pH and conductivity were not high on the Rhodamine B degradation.

      • KCI등재

        Box-Behnken법을 이용한 E. coli 소독에서 전기-UV-초음파 복합 공정의 최적화

        김동석,박영식,Kim, Dong-Seog,Park, Young-Seek 대한환경공학회 2011 대한환경공학회지 Vol.33 No.3

        수중에서 E. coli 소독을 위한 전기-UV-초음파 복합 공정에 대해 실험계획법과 반응표면분석법(RSM)을 적용하였다. 2차반응표면 모형식을 추정할 수 있는 Box-Behnken법을 이용하여 전기-UV-초음파 복합 공정의 소독 반응에서 전기분해($X_1$), UV ($X_2$), 및 초음파 공정($X_3$)의 전력을 독립변수로 선정하여 수학적으로 모형화하였다. 소독 후 잔류 E. coli 수와 독립변수 사이의 실험에서 독립변수에 대해 다음의 모형식이 얻어졌다. 잔류 E. coli number (Ln CFU) = 23.69 - 3.75 Electrolysis - 0.67 UV - 0.26 Ultrasonic - 0.16 Electrolysis UV + 0.05 Electrolysis Ultrasonic + 0.27 $Electrolysis^2$ + 0.14 $UV^2$ - 0.01 $Ultrasonic^2$). 예측된 모형식은 실험 자료와 잘 일치하였다($R^2$ = 0.983). 2차원 등고선도와 3차원 반응표면도가 잔류 E. coli 수에 대한 최적 범위를 구하기 위하여 사용되었다. Design-Expert 소프트웨어의 '수치 최적화'를 이용하여 잔류 E. coli 수에 대한 최적 값을 찾은 결과 1.47 Ln CFU/L이었고, 최적 조건은 전기분해 6.94 W, UV 6.72 W 및 초음파 공정 14.23 W로 나타났다. 본 연구는 반응표면분석법이 복합 소독 공정에서 잔류 E. coli 수를 최소화하고 운전 조건을 최적화하기 위한 적절한 방법 중의 하나라는 것을 보여주었다. This experimental design and response surface methodology (RSM) have been applied to the investigation of the electro-UV-ultrasonic complex process for the disinfection of E. coli in the water. The disinfection reactions of electro-UV-ultrasonic process were mathematically described as a function of parameters power of electrolysis ($X_1$), UV ($X_2$), and ultrasonic process ($X_3$) being modeled by use of the Box-Behnken technique, which was used for fitting 2nd order response surface model. The application of RSM yielded the following regression equation, which is empirical relationship between the residual E. coli number (Ln CFU) in water and test variables in coded unit: residual E. coli number (Ln CFU) = 23.69 - 3.75 Electrolysis - 0.67 UV - 0.26 Ultrasonic - 0.16 Electrolysis UV + 0.05 Electrolysis Ultrasonic + 0.27 $Electrolysis^2$ + 0.14 $UV^2$ - 0.01 $Ultrasonic^2$). The model predictions agreed well with the experimentally observed result ($R^2$ = 0.983). Graphical 2D contour and 3D response surface plots were used to locate the optimum range. The estimated ridge of maximum response and optimal conditions for residual E. coli number (Ln CFU) using 'numerical optimization' of Design-Expert software were 1.47 Ln CFU/L and 6.94 W of electrolysis, 6.72 W of UV and 14.23 W of ultrasonic process. This study clearly showed that response surface methodology was one of the suitable methods to optimize the operating conditions and minimize the residual E. coli number of the complex disinfection.

      • KCI등재

        전기-펜톤 공정에 의한 페놀의 전기화학적 분해

        김동석,박영식,Kim, Dong-Seog,Park, Young-Seek 한국환경보건학회 2009 한국환경보건학회지 Vol.35 No.3

        Oxidation of phenol in aqueous media by electro-Fenton process using Ru-Sn-Sb/graphite electrode has been studied. Hydrogen peroxide was electrically generated by reaction of dissolved oxygen in acidic solutions containing supporting electrolyte and $Fe^{2+}$ was added in aqueous media. Phenol degradation experiments were performed in the presence of electrolyte media at pH 3. Effect of operating parameters such as current, electrolyte type (NaCl, KCl and $Na_2SO_4$) and concentration, $Fe^{2+}$ concentration, air flow rate and phenol concentration were investigated to find the best experimental conditions for achieving overall phenol removal. Results showed that current of 2 A, NaCl electrolyte concentration of 2g/l, 0.5M concentration of $Fe^{2+}$, air flow rate of 1l/min were the best conditions for mineralization of the phenol by electro-Fenton.

      • KCI등재

        3차원 전극을 사용한 Rhodamine B의 전기분해에 미치는 운전인자의 영향

        김동석,박영식,Kim, Dong-Seog,Park, Young-Seek 한국환경보건학회 2009 한국환경보건학회지 Vol.35 No.4

        A simulated wastewater containing the dye Rhodamine B (RhB) was electrolytically treated using a three-dimensional electrode reactor equipped with granular activated carbon (GAC) as particle electrode. The effect of type of packing material (GAC, ACF, Nonwoven fabric fiber coated with activated carbon), amounts of GAC packing (25-100 g), current (0.5-3 A) and electrolyte concentration (0.5-3 g/l) was evaluated. Experimental results showed that performance for RhB decolorization of the 3 three-dimensional electrodes lie in: GAC > Nonwoven fabric fiber > ACF. When considered RhB decolorization, oxidants concentration and electric power, optimum GAC dosage was 50 g. Generated concentration of 3 oxidants ($ClO_2$, free Cl, $H_2O_2$) was increased with increase of applied current, however optimum current for RhB degradation was 2.5 A. The oxidants concentration was increased with increase of NaCl concentration and optimum NaCl dosage for RhB degradation was 1.5 g/l.

      • KCI등재

        SBR에서 포기기간 변경에 따른 질소.인 제거 특성

        김동석,박영식,Kim, Dong-Seog,Park, Young-Seek 한국환경보건학회 2009 한국환경보건학회지 Vol.35 No.2

        Laboratory scale experiments were conducted to investigate the removal characteristics of nitrogen and phosphorus by the variation of aeration time in four sequencing batch reactors (SBRs). In R1 which has the shortest aeration time as 1 h, MLVSS concentration in reactor decreased by the wash-out of biomass because of the poor sedimentation. The TOC removal efficiencies were almost similar in 3 reactors except R1. At the low aeration time as 1 h, the nitrification was severely inhibited by the deficiency of oxygen. ${NH_4}^+$-N removal efficiency was decreased by the decrease of aeration time. At the aeration time over 2 h, the phosphorus removal efficiency was not affected by the variation of aeration time. The nitrification was inhibited but the phosphorus release and uptake was not inhibited by the decrease of low aeration time. Therefore, we can see that the phosphorus removal microorganisms are superior to nitrification microorganisms in oxygen utilization.

      • KCI우수등재

        전기응집/부상 공정에서 반응표면분석법을 이용한 TiO<sub>2</sub> 수용액의 탁도 처리조건 최적화

        김동석,박영식,Kim, Dong-Seog,Park, Young-Seek 한국환경보건학회 2009 한국환경보건학회지 Vol.35 No.6

        The removal of turbidity from $TiO_2$ wastewater by an electrocoagulation/flotation process was studied in a batch reactor. The response surface methodology (RSM) was applied to evaluate the simple and combined effects of the three main independent parameters, current, NaCl dosage and initial pH of the $TiO_2$ solution on the turbidity removal efficiency, and to optimize the operating conditions of the treatment process. The reaction of electrocoagulation/flotation was modeled by use of the Box-Behnken method, which was used for the fitting of a 2nd order response surface model. The application of RSM yielded the following regression equation, which is an empirical relationship between the turbidity removal efficiency of $TiO_2$ wastewater and test variables in uncoded unit: Turbidity removal (%)=69.76+59.76Current+11.98NaCl+4.67pH+5.00Current${\times}$pH-160.11$Current^2-0.34pH^2$. The optimum current, NaCl dosage and pH of the $TiO_2$ solution to reach maximum removal rates were found to be 0.186 A, 0.161 g/l and 7.599, respectively. This study clearly showed that response surface methodology was one of the most suitable method to optimize the operating conditions for maximizing the turbidity removal. Graphical response surface and contour plots were used to locate the optimum point.

      • KCI등재

        응집과 균질화가 팽화슬러지의 용존공기부상과 침전에 미치는 영향

        김동석,박영식,Kim, Dong-Seog,Park, Young-Seek 한국환경보건학회 2007 한국환경보건학회지 Vol.33 No.1

        The objective of this study is to examine the effect of the coagulation and homogenization in bulking sludge thickening of paper manufacturing plant using DAF(Dissolved Air Flotation) and gravitational sedimentation. The effects of parameters such as dosage of coagulant and homogenization time were examined. The results showed that DAF and sedimentation was affected aluminum sulfate and anion polymer coagulant differently. At the optimum dosage of aluminum sulfate, thickening efficiency of DAF and sedimentation process were increase 1.25 time and 2.02 time, respectively. At the optimum dosage of anion polymer coagulant, thickening efficiency of DAF process was increase 1.35 time, but thickening efficiency at sedimentation was 1.06 time. When anion polymer coagulant of 0.5 mg/l was added in DAF process, water content of sludge was decreased from 96.6% to 90.7% in dewatering process using Buchner funnel test device. After homogenization(20500 rpm, 10 min), Sauter mean diameter of sludge floc was decreased from 631 ${\mu}m$ to 427 ${\mu}m$, however increase of flotation efficiency by DAF was only 1.09 time.

      • KCI등재

        멀티 플라즈마 반응기를 이용한 E. coli 소독

        김동석,박영식,Kim, Dong-Seog,Park, Young-Seek 한국환경보건학회 2013 한국환경보건학회지 Vol.39 No.2

        Objectives: For the practical application of the dielectric barrier discharge plasma reactor, a plasma reactor able to manage large volumes of water is needed. This study investigated the possibility of the practical application of a multi-plasma reactor which is a scaled-up version of a single plasma reactor. Methods: The multi-plasma reactor consists of several high-voltage transformers and plasma modules (discharge, ground electrodes and quartz dielectric tubes). The effects of water characteristics such as voltage (30-120 V), air flow rate (1-5 l/min), number of high-voltage transformers and plasma modules, and water quality on Escherichia coli (E. coli) disinfection and decrease of COD and $UV_{254}$ absorbance were investigated. Results: The experimental results showed that at a voltage of over 80 V, most of the E. coli were disinfected within 90 seconds. E. coli inactivation was not affected by the air flow rate. E. coli disinfection in the multiplasma process showed the traditional log-linear form of the disinfection curve. E. coli inactivation performance by transformer 3-Reactor 5 and transformer 3-Reactor 3 were similar. The disinfection performance of the UV process was affected by artificial sewage water. However, the plasma process was less affected by the artificial sewage within the standards for effluent water quality. Conclusions: Disinfection performance with several low voltages and plasma modules of three to five in number applied to the plasma process was higher than that concentrating a small amount of high voltage through a single plasma reactor. Removal of COD, $UV_{254}$ absorbance, and E. coli disinfection with the plasma process were better than with the UV process.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼