http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
과도안정도 제약을 고려한 발전기 단자전압 최적 제어 방안에 대한 연구
서상수(Sangsoo Seo) 대한전기학회 2021 전기학회논문지 Vol.70 No.12
In this paper, we propose a method to solve the system overvoltage problem without causing the transient stability problem under light load of the power system. The optimal voltage can be found by applying the operating voltage constraints and transient stability constraints to the existing optimization function which the minimizing losses is the objective function. The method of applying the transient stability constraint is divided into two steps. The first is to find the voltage range of the power plant that satisfies the transient stability. Next, the optimal operating voltage is calculated by considering the derived voltage range as the voltage range constraint of the generator of the optimization function. The calculated the optimal reference voltage of generators can solve the system overvoltage problem without impairing the transient stability in case of a power system light load situation. The effect of the proposed scheme was verified using a light load Korean power system.
서상수(Sangsoo Seo),김대정(Daejeong Kim),최윤혁(Yoon-Hyuk Choi),이병준(Byongjun Lee) 대한전기학회 2011 전기학회논문지 Vol.60 No.4
This paper defines a generator reactive reserve considering power system network. Conventional generator reserve is calculated by the difference between the maximum reactive power output of generator and the current reactive power of generator. However, all generators could not affect on the whole power system. Thus, the effective generators should be selected by sensitivity analysis. The sensitivity depends on network configuration is the relation between generator reactive power outputs and reactive power loads. Using the sensitivity, the effective generator reactive reserve can be calculated.
발전기차단 지수를 이용한 지능형 고장파급방지 장치 알고리즘 개발
서상수(Sangsoo Seo),김동준(Dong-Joon Kim),김석주(Seog-Joo Kim),문영환(Young-Hwan Moon) 대한전기학회 2011 대한전기학회 학술대회 논문집 Vol.2011 No.10
This paper presents a algorithm for intelligent generator SPS(Special Protection System) using a index for tripping generator. The proposed index is calculated by PMU(Phasor Measurement Unit) data. It can reflect a state in the power system. In order to use the tripping generator index, a patching matrix is created by off-line study. The patching matrix shows the number of tripping generator with regard to the tripping generator index. The algorithm can set up the tripping generators for the SPS using the matrix. This method is demonstrated by the Korean Power System in 2010.
서상수(Sangsoo Seo),김동준(Dong-Joon Kim),김석주(Seog-Joo Kim),문영환(Young-Hwan Moon),김진이(Jin-Yi Kim),김우선(Woo-Sun Kim) 대한전기학회 2011 대한전기학회 학술대회 논문집 Vol.2011 No.10
This report provides a study of effect on new interconnection in Dangjin area in terms of transient stability. KEPCO is planning to build a HVDC and HVAC line in Dangjin area in 2015. The case study used the Korean power system in summer peak in 2011. The results have been compared with the present status and test scenario followed the guidelines for analysis of transient stability in KEPCO system.
서상수(Sangsoo Seo),송성환(Sung-Hwan Song),문영환(Young-Hwan Moon) 대한전기학회 2010 대한전기학회 학술대회 논문집 Vol.2010 No.11
전세계적을 풍력발전은 많은 신재생 에너지원 중에서 가장 각광받고 있는 발전 방식이다. 현재 많은 나라에서 풍력발전 설비가 설치 운전되고 있다. 나아가 각 국에서는 지구 온난화 문제 해결을 위해 화석에너지 사용을 줄이려는 노력의 일안으로 풍력발전 분야에 많은 투자를 계획 중에 있다. 이러한 풍력발전은 기존의 발전 방식과 그 특성이 매우 상이하다. 그리고 그 상이한 특성은 풍력발전 단지의 용량이 커짐에 따라 계통에 미치는 영향은 더 확대되게 된다. 따라서 대규모 풍력단지가 주는 영향을 파악하기 위한 많은 계통 해석이 요구된다. 계통해석을 위해서는 정확한 풍력 모델이 필요하며, 지금까지 다양한 노력이 이루어져 왔다. 이에 본 논문은 현재 많이 사용되고 있는 풍력 모델의 특성을 검토해 보고자 한다.