http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Assessment of the dietary intake of propylene glycol in the Korean population
Lim, Ho Soo,Hwang, Ju Young,Choi, EunA,Lee, Gun Young,Yun, Sang Soon,Kang, TaeSeok Taylor Francis 2016 Food additives & contaminants. Part A. Chemistry, Vol.33 No.8
<P>An improved method for the analysis of propylene glycol (PG) in foods using a gas chromatography-flame ionisation detector (GC-FID), with confirmation by GC-MS, was validated by measuring several analytical parameters. The PG concentrations in 1073 products available in Korean markets were determined. PG was detected in 74.1% of the samples, in a concentration range from the limit of detection (n.d., 0.39 gml(-1)) to 12,819.9mgkg(-1). The Korea National Health and Nutrition Examination Survey (KNHANES) 2011-2013 reported the mean intake levels of PG from all sources by the general population and consumers were 26.3mg day(-1) (0.52mgkg(-1) day(-1)) and 34.3mg day(-1) (0.67mgkg(-1) day(-1)), respectively. The 95th percentile intake levels of the general population and consumers were 123.6mg day(-1) (2.39mgkg(-1) day(-1)) and 146.3mg day(-1) (2.86mgkg(-1) day(-1)), respectively. In all groups of the general population, breads were the main contributors to the total PG intake. These reports provide a current perspective on the daily intake of PG in the Korean population.</P>
이태석(Taeseok Lee),손진관(Jinkwan Son),진유정(Yujeong Jin),이동관(Donggwan Lee),장재경(Jaekyung Jang),백이(Yee Paek),임류갑(Ryugap Lim) 한국산학기술학회 2020 한국산학기술학회논문지 Vol.21 No.12
본 연구에서는 시설원예 농가 중 지하수 수질에 문제가 있는 농가와 지하수를 원활히 사용하는 농가의 수질성분을 분석하고 비교하였다. 이를 통해, 국내 수경재배 시설을 대상으로 지하수 수질에 따라 양액 재배용 원수로 사용가능성을 평가하였다. 지하수 수질에 문제가 없는 농가의 지하수는 평균적으로 pH 6.61, EC 0.27 dS/m, NO₃-N 7.64mg/L, NH₄<SUP>+</SUP>-N 0.80 mg/L, PO₄-P 0.09 mg/L, K<SUP>+</SUP> 6.26 mg/L, Ca<SUP>2+</SUP> 18.57 mg/L, Mg<SUP>2+</SUP> 4.38 mg/L, Na<SUP>+</SUP> 20.85mg/L, Cl- 18.10 mg/L, S²- 7.97 mg/L, HCO₃- 55.06 mg/L, Fe 0.09 mg/L, Mn 0.01 mg/L, Zn 0.04 mg/L, Cu 0.01 mg/L, B 0.04 mg/L, Si<SUP>4+</SUP> 8.93 mg/L, Mo 0.01 mg/L로 나타났으며, 모두 양액 재배용 원수의 수질기준을 만족하였다. 반면, 지하수 수질에 문제가 있는 농가의 경우 대다수의 항목이 양액재배용 원수의 수질기준을 초과하였다. 이러한 성분분석 결과로 보아 작물재배에 적합하지 않은 수질의 지하수를 정수하여 원수로 사용하는 것은 지하수의 재충전, 토양정화 측면에서 효과가 있다고 판단된다. 본 연구결과를 바탕으로 농업용 정수시스템을 구성한다면 우선처리 대상 항목 및 연계 항목을 추측할 수 있어 설계가 용이할 것으로 판단된다. 또한 이러한 농업용 정수시스템을 정착시킨다면 시설원예 단지에서 직접 지하수를 사용하면서 재충전 및 재이용할 수 있고, 결과적으로 지속가능한 농업과 국토 정화에 이바지 할 수 있는 기본 정보를 제공한다. This study analyzed groundwater quality in hydroponic cultivation facilities. Through this study, the possibility of groundwater use was evaluated according to the quality of the groundwater for hydroponic cultivation facilities. Good groundwater quality, on average, is pH 6.61, EC 0.27 dS/m, NO₃-N7.64 mg/L, NH₄<SUP>+</SUP>-N 0.80 mg/L, PO₄-P 0.09 mg/L, K<SUP>+</SUP> 6.26 mg/L, Ca<SUP>2+</SUP> 18.57 mg/L, Mg<SUP>2+</SUP> 4.38 mg/L, Na<SUP>+</SUP>20.85 mg/L, etc. All of these satisfy the water quality standard for raw water in nutrient cultivation. But in the case of farmers experiencing problems with groundwater quality, most of the items exceeded the water quality standard. As a result of the analysis, it was judged that purifying groundwater of unsuitable quality for crop cultivation, and using it as raw water, was effective in terms of water quality and soil purification. If an agricultural water purification system is constructed based on the results of this study, it is judged that the design will be easy because the items to be treated can be estimated. If a purification system is established, it can use groundwater directly in the facility and for horticulture. These study results will be available for use in sustainable agriculture and environments.
능동적 가중행렬 변환을 이용한 DACS 추진기관의 강인한 추력 분배기법
기태석(Taeseok Ki),박익수(Iksoo Park),김중회(Junghoe Kim),임성택(Seong-Taek Lim),민성기(Seongki Min) 한국추진공학회 2016 한국추진공학회 학술대회논문집 Vol.2016 No.12
고체 추진제를 연료로 사용하는 DACS의 강인한 추력 분배기법에 대한 연구를 수행하였다. 추진기관이 제어해야 하는 추력의 자유도보다 많은 구동 노즐을 보유한 시스템에 대하여, 비정상적인 상황을 허용할 수 있는 강인한 추력제어 기법을 제안하였다. 추력 분배기법에 의해 각 노즐로 인가된 명령 대비 응답 노즐 목 면적 크기의 차이를 이용하여 추력 분배기법에 적용된 가중행렬을 실시간으로 변환시키는 기법을 적용하였다. 이를 통하여 오차가 발생한 노즐의 추력 분배 비율을 감소시키고, 결론적으로 시스템에 요구하는 추력 오차를 감소시키도록 하였다. 제안된 기법에 대하여 DCS와 ACS 각각의 구동장치가 제어명령을 추종하지 못하는 임의의 고장조건을 모의하였고, 시뮬레이션을 통해 기법의 성능을 검증하였다. Robust thrust distribution method of solid DACS is researched. For the case of the system which has higher number of actuation nozzles than the degree of freedom of thrust to be controlled, the robust thrust allocation law which accommodate the abnormal operation is suggested. Assuming the situation that some nozzles are uncontrollable, the error between nozzle throat area command and response can be calculated. The error is used for realtime reshaping of weighting matrix. From the weighting effect, the nozzle which operated abnormally has low responsibility for the command then, the thrust error is reduced. The suggested algorithm is verified by the simulation of abnormal operation condition of DCS and ACS nozzle respectively.
JungJin Lim,유창규,Boddupalli Sankarrao,TaeSeok Oh,MinJung Kim,OnYu Kang,김정태 한국화학공학회 2012 Korean Journal of Chemical Engineering Vol.29 No.9
The amount of greenhouse gases (GHG), especially, nitrous oxide (N2O) emitted from wastewater treatment plants (WWTP) using data reconciliation and closed-loop mass balance was estimated. This study is based on a flowbased emission estimation approach which depends on the accuracy of the measurement data. To reduce the (random)measurement error, data reconciliation was used to enhance the accuracy of the flow measurements. After performing data reconciliation, N2O emission was estimated with more precision by using the closed-loop mass balance. The results in both pilot-scale and full-scale plants show that the suggested method can easily obtain the precise flow measurement for GHG emission, which in turn, results in the accurate estimation of the N2O amounts emitted from WWTP. Moreover, it is shown that the estimated flowrate values can be used as a software sensor, which can replace the faulty sensors and can validate the existing field measurements.
동절기 대향류형 환기장치의 온실 내 습도 조절 효과 분석
이태석(Taeseok Lee),강금춘(Geumchoon Kang),장재경(Jaekyung Jang),백이(Yee Paek),임류갑(Ryugap Lim) (사)한국생물환경조절학회 2020 생물환경조절학회지 Vol.29 No.3
본 연구에서는 겨울철 보온으로 인해 야간 및 새벽에 상대습도가 높아지는 온실에 대향류형 환기장치를 설치하고 그 효과를 분석하였다. 대향류형 환기장치는 크기 0.96×0.65×0.82(W×D×H, m)의 케이스에 크기 0.54×0.40×0.75(W×D×H, m)의 PE소재의 열교환 소자와 급기와 배기를 위한 송풍팬(풍량 6,800m³/h, 소비전력 1.7kW) 2대가 내부에 있다. 환기장치는 총 2대를 이용하였으며 토마토의 적정 생육 환경을 고려하여 설정 습도를 80%하고 18시부터 익일 8시까지 온실 내 온도 및 습도를 측정하고 분석하였다. 관행 온실에서 야간 평균 온도 및 습도는 14.9℃, 82.8%, 시험구 온실에서 야간평균 온습도는 15.1℃, 79.9%로 측정되어 온도는 0.1℃, 습도는 약 3% 차이가 났다. 온실 평균 온도 및 습도를 월별로 비교하고 독립표본 t검정을 통해 분석해 본 결과, 유의수준 1%에서 각 월의 온도는 차이가 없는 것으로 나타났으며 습도는 차이가 있다고 판단된다. 따라서 대향류형 환기장치의 사용이 온실의 습도를 관리하고 작물 생육에 적합환 환경을 조성하여 작물 생산성 향상에 도움을 줄 수 있다고 판단된다. 이 외에도 환기장치 사용에 따른 난방비 증가와 같은 손실적 요소와 이익적 요소를 복합적으로 고려한 추가적인 연구도 필요할 것으로 사료된다. In this study, the humidity control effect of a counter-flow ventilator was analyzed in a greenhouse with high relative humidity at night in the winter season. A case of the counter-flow ventilator was 0.96 × 0.65× 0.82(W× D × H, m) and there were heat transfer element and two fans for air supply and exhaust in the counter-flow ventilator. Two counter-flow ventilators were used in this study and the setting humidity of the ventilators was 80%. The temperature and relative humidity at night(18:00-8:00) in the greenhouse were measured. In a greenhouse without a counter-flow ventilator, the average temperature and humidity was 14.9°C, 82.8%, respectively. When the counter-flow ventilator was operated, the corresponding averages were 15.1°C, 79.9%. The independent sample t test of monthly temperature and relative humidity showed no difference in temperature, and a significant difference in relative humidity with 1% of the significance level. Therefore, using the counter-flow ventilator helps to control relative humidity in greenhouse and increase yield.. And further research considering the pros and cons of using the counter-flow ventilator is needed.