RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        Novel Landmark for Cervical Pedicle Screw Insertion Point from Computed Tomography-Based Study

        Kazuya Nishizawa,Kanji Mori,Akira Nakamura,Shinji Imai 대한척추외과학회 2017 Asian Spine Journal Vol.11 No.1

        Study Design: Cross-sectional study. Purpose: The purpose of this study was to evaluate a novel landmark for the cervical pedicle screw insertion point. Overview of Literature: To improve the accuracy of pedicle screw placement, several studies have employed the lateral mass, lateral vertical notch, and/or inferior articular process as landmarks; however, we often encounter patients in whom we cannot identify accurate insertion points for pedicle screws using these landmarks because of degenerative changes in the facet joints. The superomedial edge of the lamina is less affected by degenerative changes, and we hypothesized that it could be a new landmark for identifying an accurate cervical pedicle screw insertion point. Methods: A total of 327 consecutive patients, who had undergone neck computed tomographic scanning for determination of neck disease in our institute, were included in the study. At first, the line was drawn parallel to the superior border of the pedicle in the sagittal plane and parallel to the vertical body in the coronal plane. The line was moved downward in 1-mm increments to the inferior border of the pedicle. We determined whether the line passing through the superomedial edge of the lamina (termed the “N-line”) was located between the superior and inferior borders of the pedicle in the sagittal plane. Results: The percentages of N-lines located between the superior and inferior borders of the pedicle were 100% at C3, 100% at C4, 99% at C5, 96% at C6, and 97% at C7. The lower cervical spine has the higher N-line location. Conclusions: The N-line was frequently located at the level of the pedicle of each cervical spine in the sagittal plane. The superomedial edge of the lamina could be a new landmark for the insertion point of the cervical pedicle screw.

      • KCI등재

        Short-Term Clinical Result of Cortical Bone Trajectory Technique for the Treatment of Degenerative Lumbar Spondylolisthesis with More than 1-Year Follow-Up

        Kanji Mori,Kazuya Nishizawa,Akira Nakamura,Shinji Imai 대한척추외과학회 2016 Asian Spine Journal Vol.10 No.2

        Study Design: Retrospective follow-up study on the result of surgical treatment for patients with degenerative lumbar spondylolisthesis (DLS) using cortical bone trajectory (CBT) technique. Purpose: To evaluate the capability of CBT to manage patients with DLS. Overview of Literature: CBT is a recently advocated, novel, less-invasive technique of lumbar pedicle screw, which provides enhanced screw purchase by maximizing the thread contact with higher density bone surface. Despite the frequent use of CBT technique in the lumbar spine surgery, little is known of the capability of this technique to manage patients with DLS. Methods: Thirty two consecutive patients (5 males, 27 females) surgically treated with single-level DLS in our institute using CBT were included. All patients were followed up at least 12 months (mean 24 months). Their clinical and radiological features were measured. Results: Good leg pain relief was achieved in all patients. The mean postoperative percentage slip demonstrated significant reduction with significant neurological recovery when compared with preoperative percentage slip, and it was maintained until the latest follow-up. Loss of correction of more than 3 mm during the follow-up period was observed in 3 cases. Surgical site infection was observed in one case; however, pull-out of PSs or neurological deterioration was not found. No patient needed additional surgery during the follow-up period. Conclusions: These preliminary results confirmed that CBT is useful for the treatment for patients with DLS. This technique allows good reduction of spondylolisthesis and neurological improvement.

      • Design of Flux-Axis Angular Speed Estimation using Induced Voltage in Speed Sensor-less Field Oriented Control for Induction Motor

        Jun-ichi Itoh,Kazuya Kawai,Koroku Nishizawa,Hiroki Watanabe 전력전자학회 2019 ICPE(ISPE)논문집 Vol.2019 No.5

        This paper proposes a design method of the flux-axis angular speed estimation using induced voltage in a speed sensor-less field oriented control for induction motor (IM) drive systems. In this method, the d-axis induced voltage is regulated to zero by a feedback control to estimate the fluxaxis angular speed. A low pass filter (LPF) is necessary in this estimation to avoid the recursive calculation. In this paper, the design method of compensation gain kpem and the cut-off angular frequency of LPF ωlpf are considered. As a result, the relation between kpem, ωlpf, convergence time of the d-axis induced voltage have a match to the equation and designed model in this paper. Furthermore, the maximum error between the simulation and estimated results of the time constant of the flux-axis angular speed introduced due to LPF is 3.7% when ωlpf is 200 rad/s. As the experimental results, when a torque step of 100% is applied to the induction motor, the convergence time of the motor speed is 1.6 s as the worst case with kpem set as 2.0 p.u. and the cut-off angular frequency set as 1000 rad/s. However, if kpem is set as 2.0 p.u. and ωlpf is set as 400 rad/s, the convergence time of the motor speed is 0.43 s as the best case, which is reduced by 73.1% compared to the worst case. As the result, kpem should decide by the target steady-state error, lpf should bigger than the cut-off angular frequency of the PI controller ωASR. Where, if the ωlpf is high, the convergence time of the motor speed is high.

      • KCI등재

        Navigated Pin-Point Approach to Osteoid Osteoma Adjacent to the Facet Joint of Spine

        Kanji Mori,Masashi Neo,Mitsuru Takemoto,Kazuya Nishizawa,Shinji Imai 대한척추외과학회 2016 Asian Spine Journal Vol.10 No.1

        Osteoid osteoma (OO) is a benign osteoblastic tumor. Its curative treatment is complete removal of the nidus, where intraoperative localization of the nidus governs clinical results. However, treatment can be difficult since the lesion is often invisible over the bony surface. Accordingly, establishment of an ideal less invasive surgical strategy for spinal OO remains yet unsettled. We illustrate the efficacy of a computed tomography (CT)-based navigation system in excising OO located adjacent to the facet joint of spine. In our 2 cases, complete and pin-point removal of the nidus located close to the facet joint was successfully achieved, without excessive removal of the bone potentially leading to spinal instability and possible damage of nearby neurovascular structures. We advocate a less invasive approach to spinal OO, particularly in an environment with an available CT-based navigation system.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼