The influence of saliva pH value on the retention and durability of bar-clip attachments
Raul Ustrell,Ana Cristina Braga,Jose Manuel MendeTomas Escuin,Carlos Aroso,Antonio Sergio Silva 대한치과보철학회 2015 The Journal of Advanced Prosthodontics Vol.7 No.1
PURPOSE The aim of this study was to compare the durability and retention of 4 types of attachments placed over computer aided design/computer aided manufacturing (CAD/CAM) titanium bars when subjected to different pH conditions. MATERIALS AND METHODS Four commercially available attachments were investigated: Hader Yellow, Hader Red, Ackerman Gold and Ackerman Stainless Steel. These attachments and Ackerman CAD/CAM titanium bars were placed in 2 vessels containing different artificial saliva solutions (pH 7/pH 4) at 37℃ for one month to simulate corrosion conditions, and they were then subjected to mechanical testing (5400 cycles of insertion and removal). RESULTS The results revealed that there were significant differences in the average values of insertion/removal force due to the pH (F (1, 24)=9.207, P<.05) and the type of attachment (F (3, 24)=11.742, P<.05). CONCLUSION More acidic pH values were found to have a negative influence on the retention capacity of the attachments.
The influence of saliva pH value on the retention and durability of bar-clip attachments
Silva, Antonio Sergio,Aroso, Carlos,Ustrell, Raul,Braga, Ana Cristina,Mendes, Jose Manuel,Escuin, Tomas The Korean Academy of Prosthodonitics 2015 The Journal of Advanced Prosthodontics Vol.7 No.1
PURPOSE. The aim of this study was to compare the durability and retention of 4 types of attachments placed over computer aided design/computer aided manufacturing (CAD/CAM) titanium bars when subjected to different pH conditions. MATERIALS AND METHODS. Four commercially available attachments were investigated: Hader Yellow, Hader Red, Ackerman Gold and Ackerman Stainless Steel. These attachments and Ackerman CAD/CAM titanium bars were placed in 2 vessels containing different artificial saliva solutions (pH 7/pH 4) at $37^{\circ}C$ for one month to simulate corrosion conditions, and they were then subjected to mechanical testing (5400 cycles of insertion and removal). RESULTS. The results revealed that there were significant differences in the average values of insertion/removal force due to the pH (F (1, 24)=9.207, P<.05) and the type of attachment (F (3, 24)=11.742, P<.05). CONCLUSION. More acidic pH values were found to have a negative influence on the retention capacity of the attachments.
Carlos Aroso,Antonio Sergio Silva,Raul Ustrell,Jose Manuel Mendes,Ana Cristina Braga,Esther Berastegui,Tomas Escuin 대한치과보철학회 2016 The Journal of Advanced Prosthodontics Vol.8 No.1
PURPOSE This in vitro study investigated and compared the durability and retention of three types of attachments. MATERIALS AND METHODS Three commercially available attachments were investigated: Clix®, Dalbo-Plus® and Locator®. In total, 72 samples of these attachments were placed in the acrylic resin forms and subjected to mechanical testing (5400 cycles of insertion and removal) over the respective ball or Locator abutments immersed in artificial saliva at pH 7 and 37℃. The abutments were placed at angulations of 0°, 10° and 20°. The retention force was recorded at the beginning and after 540, 1080, 2160, 3240, 4320 and 5400 insertion-removal cycles. RESULTS The results revealed that there were significant differences in the average values of the insertion/removal force due to angulation (F (2.48) = 343619, P<.05) and the type of attachment (F (7.48) = 23.220, P<.05). CONCLUSION Greater angulation of the abutments was found to influence the retention capacity of the attachments, and the fatigue test simulating 5 years of denture insertion and removal did not produce wear in the metal abutments.
Aroso, Carlos,Silva, Antonio Sergio,Ustrell, Raul,Mendes, Jose Manuel,Braga, Ana Cristina,Berastegui, Esther,Escuin, Tomas The Korean Academy of Prosthodonitics 2016 The Journal of Advanced Prosthodontics Vol.8 No.1
This in vitro study investigated and compared the durability and retention of three types of attachments. MATERIALS AND METHODS. Three commercially available attachments were investigated: $Clix^{(R)}$, Dalbo-$Plus^{(R)}$ and $Locator^{(R)}$. In total, 72 samples of these attachments were placed in the acrylic resin forms and subjected to mechanical testing (5400 cycles of insertion and removal) over the respective ball or Locator abutments immersed in artificial saliva at pH 7 and $37^{\circ}C$. The abutments were placed at angulations of $0^{\circ}$, $10^{\circ}$ and $20^{\circ}$. The retention force was recorded at the beginning and after 540, 1080, 2160, 3240, 4320 and 5400 insertion-removal cycles. RESULTS. The results revealed that there were significant differences in the average values of the insertion/removal force due to angulation ($F_{(2.48)}=343619$, P<.05) and the type of attachment ($F_{(7.48)}=23.220$, P<.05). CONCLUSION. Greater angulation of the abutments was found to influence the retention capacity of the attachments, and the fatigue test simulating 5 years of denture insertion and removal did not produce wear in the metal abutments.