http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Arash Kiyoumarsi,Mohhamad Ataei,Rahmatollah Hooshmand,Arash Dehestani Kolagar 대한전기학회 2010 Journal of Electrical Engineering & Technology Vol.5 No.1
Modeling of the three phase electric arc furnace and its voltage flicker mitigation are the purposes of this paper. For modeling of the electric arc furnace, at first, the arc is modeled by using current-voltage characteristic of a real arc. Then, the arc random characteristic has been taken into account by modulating the ac voltage via a band limited white noise. The electric arc furnace compensation with static VAr compensator, Thyristor Controlled Reactor combined with a Fixed Capacitor bank (TCR/FC), is discussed for closed loop control of the compensator. Instantaneous flicker sensation curves, before and after accomplishing compensation, are measured based on IEC standard. A new method for controlling TCR/FC compensator is proposed. This method is based on applying a predictive approach with closed loop control of the TCR/FC. In this method, by using the previous samples of the load reactive power, the future values of the load reactive power are predicted in order to consider the time delay in the compensator control. Also, in closed loop control, two different approaches are considered. The former is based on voltage regulation at the point of common coupling (PCC) and the later is based on enhancement of power factor at PCC. Finally, in order to show the effectiveness of the proposed methodology, the simulation results are provided.
Kiyoumarsi, Arash,Ataei, Mohhamad,Hooshmand, Rahmat-Allah,Kolagar, Arash Dehestani The Korean Institute of Electrical Engineers 2010 Journal of Electrical Engineering & Technology Vol.5 No.1
Modeling of the three phase electric arc furnace and its voltage flicker mitigation are the purposes of this paper. For modeling of the electric arc furnace, at first, the arc is modeled by using current-voltage characteristic of a real arc. Then, the arc random characteristic has been taken into account by modulating the ac voltage via a band limited white noise. The electric arc furnace compensation with static VAr compensator, Thyristor Controlled Reactor combined with a Fixed Capacitor bank (TCR/FC), is discussed for closed loop control of the compensator. Instantaneous flicker sensation curves, before and after accomplishing compensation, are measured based on IEC standard. A new method for controlling TCR/FC compensator is proposed. This method is based on applying a predictive approach with closed loop control of the TCR/FC. In this method, by using the previous samples of the load reactive power, the future values of the load reactive power are predicted in order to consider the time delay in the compensator control. Also, in closed loop control, two different approaches are considered. The former is based on voltage regulation at the point of common coupling (PCC) and the later is based on enhancement of power factor at PCC. Finally, in order to show the effectiveness of the proposed methodology, the simulation results are provided.
Analysis and Comparison of a Permanent-Magnet DC Motor with a Field-Winding DC Motor
Arash Kiyoumarsi 대한전기학회 2009 Journal of Electrical Engineering & Technology Vol.4 No.3
The influence of magnetic saturation on electromagnetic field distribution in both a permanent- magnet direct-current (PMDC) motor and a field-winding (wound-field) direct-current (FWDC) motor, with the same output mechanical power, has been studied. In this paper, an approximate analytical method and time-stepping Finite Element Method (FEM) are used for prediction of Back-EMF and electromagnetic torque. No-load and rotor-lucked conditions, according to experimental measurements, and the FEM and analytical method studies of the motors have been considered. A sensitivity analysis has also been successfully accomplished on the major design parameters that affect motor performance. At last, these two DC motors are compared, in spite of their differences, on the basis of measured output characteristics.
Analysis and Comparison of a Permanent-Magnet DC Motor with a Field-Winding DC Motor
Kiyoumarsi, Arash The Korean Institute of Electrical Engineers 2009 Journal of Electrical Engineering & Technology Vol.4 No.3
The influence of magnetic saturation on electromagnetic field distribution in both a permanent-magnet direct-current (PMDC) motor and a field-winding (wound-field) direct-current (FWDC) motor, with the same output mechanical power, has been studied. In this paper, an approximate analytical method and time-stepping Finite Element Method (FEM) are used for prediction of Back-EMF and electromagnetic torque. No-load and rotor-lucked conditions, according to experimental measurements, and the FEM and analytical method studies of the motors have been considered. A sensitivity analysis has also been successfully accomplished on the major design parameters that affect motor performance. At last, these two DC motors are compared, in spite of their differences, on the basis of measured output characteristics.
Robust Active Power Control of a Battery-Supported DSTATCOM to Enhance Wind Generation Power Flow
Mohammad Mahdianpoor,Arash Kiyoumarsi,Mohammad Ataei,Rahmat-Allah Hooshmand 대한전기학회 2017 Journal of Electrical Engineering & Technology Vol.12 No.4
The lack of controllability over the wind causes fluctuations in the output power of the wind generators (WGs) located at the wind farms. Distribution Static Compensator (DSTATCOM) equipped with Battery Energy Storage System (BESS) can significantly smooth these fluctuations by injecting or absorbing appropriate amount of active power, thus, controlling the power flow of WGs. But because of the component aging and thermal drift, its harmonic filter parameters vary, resulting in performance degradation. In this paper, Quantitative Feedback Theory (QFT) is used as a robust control scheme in order to deactivate the effects of filter parameters variations on the wind power generation power smoothing performance. The proposed robust control strategy of the DSTATCOM is successfully applied to a microgrid, including WGs. The simulation results obviously show that the proposed control technique can effectively smooth the fluctuations in the wind turbines’ (WT) output power caused by wind speed variations; taking into account the filter parameters variations (structural parameter uncertainties).
Robust Active Power Control of a Battery-Supported DSTATCOM to Enhance Wind Generation Power Flow
Mahdianpoor, Mohammad,Kiyoumarsi, Arash,Ataei, Mohammad,Hooshmand, Rahmat-Allah The Korean Institute of Electrical Engineers 2017 Journal of Electrical Engineering & Technology Vol.8 No.1
The lack of controllability over the wind causes fluctuations in the output power of the wind generators (WGs) located at the wind farms. Distribution Static Compensator (DSTATCOM) equipped with Battery Energy Storage System (BESS) can significantly smooth these fluctuations by injecting or absorbing appropriate amount of active power, thus, controlling the power flow of WGs. But because of the component aging and thermal drift, its harmonic filter parameters vary, resulting in performance degradation. In this paper, Quantitative Feedback Theory (QFT) is used as a robust control scheme in order to deactivate the effects of filter parameters variations on the wind power generation power smoothing performance. The proposed robust control strategy of the DSTATCOM is successfully applied to a microgrid, including WGs. The simulation results obviously show that the proposed control technique can effectively smooth the fluctuations in the wind turbines' (WT) output power caused by wind speed variations; taking into account the filter parameters variations (structural parameter uncertainties).
Improvement in Computation of Δ V<sub>10</sub> Flicker Severity Index Using Intelligent Methods
Moallem, Payman,Zargari, Abolfazl,Kiyoumarsi, Arash The Korean Institute of Power Electronics 2011 JOURNAL OF POWER ELECTRONICS Vol.11 No.2
The ${\Delta}\;V_{10}$ or 10-Hz flicker index, as a common method of measurement of voltage flicker severity in power systems, requires a high computational cost and a large amount of memory. In this paper, for measuring the ${\Delta}\;V_{10}$ index, a new method based on the Adaline (adaptive linear neuron) system, the FFT (fast Fourier transform), and the PSO (particle swarm optimization) algorithm is proposed. In this method, for reducing the sampling frequency, calculations are carried out on the envelope of a power system voltage that contains a flicker component. Extracting the envelope of the voltage is implemented by the Adaline system. In addition, in order to increase the accuracy in computing the flicker components, the PSO algorithm is used for reducing the spectral leakage error in the FFT calculations. Therefore, the proposed method has a lower computational cost in FFT computation due to the use of a smaller sampling window. It also requires less memory since it uses the envelope of the power system voltage. Moreover, it shows more accuracy because the PSO algorithm is used in the determination of the flicker frequency and the corresponding amplitude. The sensitivity of the proposed method with respect to the main frequency drift is very low. The proposed algorithm is evaluated by simulations. The validity of the simulations is proven by the implementation of the algorithm with an ARM microcontroller-based digital system. Finally, its function is evaluated with real-time measurements.
Improvement in Computation of ΔV_10 Flicker Severity Index Using Intelligent Methods
Payman Moallem,Abolfazl Zargari,Arash Kiyoumarsi 전력전자학회 2011 JOURNAL OF POWER ELECTRONICS Vol.11 No.2
The ΔV_10 or 10-Hz flicker index, as a common method of measurement of voltage flicker severity in power systems, requires a high computational cost and a large amount of memory. In this paper, for measuring the ΔV_10 index, a new method based on the Adaline (adaptive linear neuron) system, the FFT (fast Fourier transform), and the PSO (particle swarm optimization) algorithm is proposed. In this method, for reducing the sampling frequency, calculations are carried out on the envelope of a power system voltage that contains a flicker component. Extracting the envelope of the voltage is implemented by the Adaline system. In addition,in order to increase the accuracy in computing the flicker components, the PSO algorithm is used for reducing the spectral leakage error in the FFT calculations. Therefore, the proposed method has a lower computational cost in FFT computation due to the use of a smaller sampling window. It also requires less memory since it uses the envelope of the power system voltage. Moreover,it shows more accuracy because the PSO algorithm is used in the determination of the flicker frequency and the corresponding amplitude. The sensitivity of the proposed method with respect to the main frequency drift is very low. The proposed algorithm is evaluated by simulations. The validity of the simulations is proven by the implementation of the algorithm with an ARM microcontroller-based digital system. Finally, its function is evaluated with real-time measurements.
Improvement in Computation of ∆ V₁₀ Flicker Severity Index Using Intelligent Methods
Payman Moallem,Abolfazl Zargari,Arash Kiyoumarsi 전력전자학회 2011 JOURNAL OF POWER ELECTRONICS Vol.11 No.2
The ?V₁? or 10-㎐ flicker index, as a common method of measurement of voltage flicker severity in power systems, requires a high computational cost and a large amount of memory. In this paper, for measuring the ?V₁? index, a new method based on the Adaline (adaptive linear neuron) system, the FFT (fast Fourier transform), and the PSO (particle swarm optimization) algorithm is proposed. In this method, for reducing the sampling frequency, calculations are carried out on the envelope of a power system voltage that contains a flicker component. Extracting the envelope of the voltage is implemented by the Adaline system. In addition, in order to increase the accuracy in computing the flicker components, the PSO algorithm is used for reducing the spectral leakage error in the FFT calculations. Therefore, the proposed method has a lower computational cost in FFT computation due to the use of a smaller sampling window. It also requires less memory since it uses the envelope of the power system voltage. Moreover, it shows more accuracy because the PSO algorithm is used in the determination of the flicker frequency and the corresponding amplitude. The sensitivity of the proposed method with respect to the main frequency drift is very low. The proposed algorithm is evaluated by simulations. The validity of the simulations is proven by the implementation of the algorithm with an ARM microcontroller-based digital system. Finally, its function is evaluated with real-time measurements.
Behzad Mirzaeian Dehkordi,Fariborz Haghighatdar Fesharak,Arash Kiyoumarsi 대한전기학회 2009 Journal of Electrical Engineering & Technology Vol.4 No.2
In this paper, a method for optimal measurement placement in the problem of static harmonic state estimation in power systems is proposed. At first, for achieving to a suitable method by considering the precision factor of the estimation, a procedure based on Genetic Algorithm (GA) for optimal placement is suggested. Optimal placement by regarding the precision factor has an evident solution, and the proposed method is successful in achieving the mentioned solution. But, the previous applied method, which is called the Sequential Elimination (SE) algorithm, can not achieve to the evident solution of the mentioned problem. Finally, considering both precision and economic factors together in solving the optimal placement problem, a practical method based on GA is proposed. The simulation results are shown an improvement in the precision of the estimation by using the proposed method.