http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
金炳國(Byong-Kuk Kim),文智虞(Ji-Woo Moon),金美廷(Mi-Jung Kim),李秉俊(Byung-Jun Lee),曺允鉉(Yun-Hyun Cho) 대한전기학회 2007 전기학회논문지 Vol.56 No.8
The line-start permanent magnet synchronous motor has a high efficiency and an advantage in constant speed operation regardless of the effect of load variation. However, it is difficult to predict the performance of characteristics accurately, because of the unbalanced starting torque with the initial starting position of the rotor and the generation of a break torque. In this paper the dynamic characteristics of the line-start permanent magnet synchronous motor are described and compared with those of the squirrel-cage induction motor through the simulation to find the characteristics of the permanent magnets and the rotor bars in the line-start permanent magnet synchronous motor. Finally this paper gives the comparison between the simulation results and the experimental results.
이윤환(Yun-Hwan Lee),김태균(Tae-Gyun Kim),권세혁(Sae-Hyuk Kwon),이병준(Byong-jun Lee) 대한전기학회 2010 대한전기학회 학술대회 논문집 Vol.2010 No.7
계통에 심각한 사고가 발생 할 경우에 가장 경제적인 방안으로 부하차단의 수행이 고려된다. 현재 우리나라의 저전압 부하차단 시에 계통의 상태를 파악하기 위하여 하나의 감시모선만을 관찰하고 있는 실정이다. 하지만 이는 계통의 상태가 위급상황이 아님에도 불구하고 부하차단 신호를 전송하여 불필요한 차단을 수행할 수 있어 추가적인 감시모선의 선정의 필요성이 대두 되고 있다. 선로정수 연속조류 계산의 민감도와 nose point 에서의 전압 변화율의 결과를 바탕으로 추가적인 감시 모선 선정 방안을 수행하였으며, 2010년도 및 2011년도의 계획 계통 데이터를 활용하여 추가 감시 모선과, 저전압 감시 기준을 선정하였다.
金泰均(Tae-Gyun Kim),李炳峻(Byong-Joon Lee),宋和昌(Hwa-Chang Song),車濬敏(Jun-Min Cha) 대한전기학회 2007 전기학회논문지 Vol.56 No.9
This paper proposes a new concept of optimal governor-response power flow (OGPF) to obtain an optimal set of control parameters when the systems are in mid-term conditions after disturbances, ignoring the system dynamics. The idea of GOPF simply comes from the attempt to find an optimal solution of the governor-response power flow (GPF), which is a pre-exiting tool that is used to get power' flow solutions that would exist several seconds after an event is applied. GPF incorporates the simplified model of governors in the systems into the power flow equations. This paper explains the concept of OGPF and depicts the OGPF formulation and application of a nonlinear interior point method as the solution technique. Also, this paper includes an example with New England 39-bus test system to illustrate the effectiveness of GOPF
효용 무효전력 예비력을 고려한 실시간 전압안정도 감시 연구
손봉균(Bong-Kyun Son),이병준(Byong-jun Lee),한상욱(Sang-Wook Han),최윤혁(Yoon-Hyuk Choi),권세혁(Sae-Hyuk Kwon) 대한전기학회 2010 대한전기학회 학술대회 논문집 Vol.2010 No.7
현재 기존의 무효전력 예비력은 계통 내에서 발전기가 갖는 무효전력 최대 발전 용량과 현재 발전기가 출력하고 있는 무효전력양의 차이로 계산이 된다. 하지만 무효전력은 국지적인 특성으로 인하여 계통 내의 모든 발전기가 전압을 유지하는데 동일한 영향을 갖지 않는다. 따라서 계통 내 주요 모선에 대한 전압 안정도 유지에 영향이 큰 발전기에 대해서 가중치를 적용하여 무효전력을 수치화하는 무효전력 예비력 산출이 필요하다. 이 새로운 무효전력 예비력을 ‘효용 무효전력 예비력(Effective Q Reserve)'이라 한다. 본 논문에서는 사고에 따라서 수도권 내에 다른 기준 모선이 선정되어 효용 무효전력 예비력을 산출하도록 한다. 본 방법을 검증하기 위해서 한전 계통을 사용한다.