http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
다목적 가속기 구축을 위한 전자 맴돌이 공명 이온원 개념 설계
이병섭(B.S. Lee),원미숙(M.S. Won),김종필(J.P. Kim),윤장희(J.H. Yoon),배종성(J.S. Bae),방정규(J.K. Bang),안정근(J.K. Ahn) 대한기계학회 2009 대한기계학회 춘추학술대회 Vol.2009 No.5
The construction of a multi-purpose linear accelerator IS ill progress by Korea Basic Science Institute. The main capability of this facility is the production of multiply ionized metal clusters and the generation more intense beams of highly charged ions for material, medical and nuclear physical research. To produce the intense beam of highly charged ions, we will construct an Electron Cyclotron Resonance Ion Source(ECRIS) using 28㎓ microwaves. For this ECRIS, The development of a conduction-cooled superconducting magnet will complete in this year. In this paper, we are introduced multi-purpose accelerator project and conceptual design of ECRIS.
28 ㎓ 초전도 ECRIS 플라즈마에서의 마이크로파 전파
왕선정(S. J. Wang),원미숙(M. S. Won),이병섭(B. S. Lee),김선호(S. H. Kim),곽종구(J. G. Kwak),정승호(S. H. Jeong),김성규(S. K. Kim),안찬용(C. Y. An) 한국진공학회(ASCT) 2010 Applied Science and Convergence Technology Vol.19 No.6
한국기초과학지원연구원 부산센터에서 개발 중인 28 ㎓ ECRIS에 대한 마이크로파 패킷의 전파와 흡수에 대한 분석을 제한된 변수 범위 내에서 실시하였다. 28 ㎓ 자이로트론에서 발생된 마이크로파는 도파관 시스템을 거쳐 자기장 및 플라즈마 캐비티의 축방향으로 입사된다. 축방향 자기장만을 고려한 분석적 Ray Tracying에 의하면 고자기장 영역에서 준 종파로 입사된 전자기 파동의 패킷은 전자 사이클로트론 공명 영역으로 진행함에 따라 바깥 방향에서 안쪽 방향으로 방향을 바꾼다. 따라서 일정 수준의 전자밀도가 유지되면 입사 초기에 발산하던 파동은 공명에 의하여 플라즈마로 흡수되기 전에 전도체인 플라즈마 캐비티 벽에 충돌할 가능성이 크지 않음을 확인하였다. 또한 플라즈마로의 흡수율이 매우 크므로 인출부 벽에서 반사될 가능성도 크지 않다. Packet propagation and absorption for the 28 ㎓ superconducting ECRIS under developing by KBSI Pusan center is analyzed with limited parameter range. The microwave power generated by 28 ㎓ gyrotron is axially injected to the plasma cavity through waveguide system. According to the analytical ray tracing calculation, the wave packet launched quasi-longitudinally at a high magnetic field side changes its direction from outward to inward as it is approaching resonance layer. Therefore, initially diverging wave does not likely hit a conducting surface before absorbing by electron cyclotron resonance. Also, absorption by plasma with moderate electron density is so strong that reflection by an extraction plate may not be expected.
양형석(H.S. Yang),김동락(D.L. Kim),이병섭(B.S. Lee),최연석(Y.S. Choi),신필권(P.K. Shin),이대희(D.H. Lee),남욱원(U.W. Nam) 대한기계학회 2006 대한기계학회 춘추학술대회 Vol.2006 No.6
We developed a space infrared cryogenic system (PSICS) for ground observation. The system is cooled down to below 80K by a stirling cryocooler in order to increase sensitivity and decrease background noise of IR sensor. From the previous thermal numerical analyses, we knew that the major heat leak is thermal radiation and the minimizing heat leak by radiation is the core technique in this system. The thermal design of the PSICS have been performed and presented at 2005 KSME conferences. In this paper, the results of the cooling test and thermal insulation effects of multi-layer insulation are discussed.