선형가속기 Upgrade 전자총 시스템설계에 관한 연구
손윤규(Yoon-Gyu Son),박성주(Sung-Ju Park),김경렬(Kyung-Ryul Kim),남상훈(Sang-Hoon Nam) 대한전기학회 2009 대한전기학회 학술대회 논문집 Vol.2009 No.7
The PLS-Ⅱ, the major upgrade program of the PLS (Pohang Light Source, a 2.5-GeV 3rd generation light source), is planned at the Pohang Accelerator Laboratory. Given the glaring lack of normative data regarding the PLS-Ⅱ the major upgrade, this study can be seen as the first in a needed stream of research investigating selection by dual gun and dc electron gun. Usable electron gun can think method to use dual electron gun and method to prove energy by existing electron gun in energy increase. This article is concerned with the formal classification of used of pre-injector electron gun type of the DC and pulse. Design concept wishes to show contents that design for pulse type of power supply and DC type of electron gun.