RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        건물 내 석면제거 작업과 공기 중 석면의 외부누출 위험성 평가

        백남원 ( Namwon Paik ),이승철 ( Soungcheoul Lee ),변재철 ( Jaecheol Byeon ),이동희 ( Donghee Lee ) 한국산업보건학회 (구 한국산업위생학회) 2020 한국산업보건학회지 Vol.30 No.4

        Objectives: The objectives of this study were to investigate whether airborne fibers were released to the outside air from the asbestos removal area in buildings, and to confirm the existence of asbestos fibers in samples using transmission electron microscopy(TEM). Methods: A total of 1,295 samples was collected from inside and outside 155 asbestos removal areas. To investigate the release of asbestos fibers from the removal area, samples were collected at three locations, such as an entrance to change room, an exit of negative pressure unit(NPU) and perimeter areas. Samples were also collected in the removal area prior to and after removal activity. All samples were analyzed by phase contrast microscopy(PCM) and one-tenth of the samples was analyzed using TEM to discriminate asbestos fibers. Results: During the asbestos removal activity, 27(4.1%) of 662 samples collected outside the removal area showed airborne fiber concentrations equal to or in excess of 0.01 f/cc, the permissible emission standard of the Korean Ministry of Environment. Further, 111 samples were analyzed using TEM. The distribution of asbestos fiber concentrations was log-normal. It was found that 51 of 111 samples(46%) contained asbestos fibers. Conclusions: There is a potential risk of asbestos exposure among neighbors and the public outside the asbestos removal areas. It is recommended that the asbestos removal work be conducted strictly following the specifications required by government and/or professional organizations.

      • KCI등재

        비열 유전체장벽방전 플라즈마의 포도상구균 및 대장균 살균효과

        김기영 ( Keyyoung Kim ),백남원 ( Namwon Paik ),김용희 ( Yonghee Kim ),유관호 ( Kwanho Yoo ) 한국산업보건학회 (구 한국산업위생학회) 2018 한국산업보건학회지 Vol.28 No.1

        Objectives: The objective of this study was to examine the effect of non-thermal dielectric barrier discharge (DBD) plasma on decontamination of Staphylococcus aureus (S. aureus) and Escherichia coli (E. coli) as common pathogens. Methods: This experiment was carried out in a chamber (0.64m<sup>3</sup>) designed by the authors. The plasma was continuously generated by a non-thermal DBD plasma generator (Model TB-300, Shinyoung Air tech, Korea). Suspensions of S. aureus and E. coli of 0.5 McFarland standard (1.5 x10<sup>8</sup>CFU/mL) were prepared using a Densi-Check photometer (bio Merieux, France). The suspensions were diluted1:1000 in sterile PBS solutions (approximately10<sup>4-5</sup>CFU/mL) and inoculated on tryptic soy agar (TSA) in Petri dishes. The Petri dishes (80mm internal diameter) were exposed to the non -thermal DBD plasma in the chamber. Results: The results showed that 95% of S. aureus colonies were killed after a six-hour exposure to the DBD plasma. In the case of E. coli, it took two hours to kill 100% of the colonies. The gram-negative E. coli had a greater reduction than the gram-positive S. aureus. This difference may be due to the structure of their cell membranes. The thickness of gram-positive bacteria is greater than that of gram-negative bacteria. The S. aureus is more resistant to DBD plasma exposures than is E. coli. It should be noted that average concentrations of ozone, a byproduct of the DBD plasma generator, were monitored throughout the experiment and the results were well below the criteria, 50 ppb, recommended by the Korean Ministry of the Environment. Thus, non-thermal DBD plasma is deemed safe for use in hospital and public facilities. Conclusions: There was evidence that non-thermal DBD plasma can effectively kill S. aureus and E. coli. The results indicate that DBD plasma technology can greatly contribute to the control of infections in hospitals and other public and private facilities.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼