RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
        • 등재정보
        • 학술지명
        • 주제분류
        • 발행연도
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재후보

        하천수 사용량 계측을 위한 개수로에서의 직접 계측방법 비교 연구

        백종석,김치영,이기성,강현웅,송재현,Baek, Jongseok,Kim, Chiyoung,Lee, Kisung,Kang, Hyunwoong,Song, Jaehyun 한국방재안전학회 2020 한국방재안전학회 논문집 Vol.13 No.4

        Continuous and accurate instrument of river water usage is needed for sustainable river water management. Although the instrument methods applicable to each point of use of river water are different, more precise direct instrument methods are required at the point of major open channel. Users of river water should select appropriate direct instrument methods to measure usage, but there is a lack of standards and verification research. In this study, the H-Q rating curve method, ultrasonic method, and microwave method were applied directly to the test basin in the upper basin of Mangyeong river, and the accuracy of measurement data was evaluated by comparing absolute error between discharge data calculated by instrument method. When comparing the calculated discharge of point units, the ultrasonic method showed the best results of the actual measurement. Through continuous instrument, the sum of the daily and monthly units was compared, and the ultrasonic and microwave methods were shown to be highly accurate. Based on the results of this study, it is hoped that the appropriate direct measurement method can be selected according to the importance of the river water use facility, considering that the ultrasonic method and the microwave method are relatively costly compared to the water level-flow relationship method. 지속가능한 하천수 관리를 위해서는 연속적이고 정확한 하천수 사용량 계측자료가 필요하다. 하천수 사용지점별로 적용가능한 계측 방법이 상이하나, 일정규모 이상의 주요 개수로 지점에서는 보다 정밀한 직접 계측방법이 요구된다. 하천수 사용자는 사용량 계측을 위해 적정한 직접 계측방법을 선정해야 하는데, 이에 대한 표준 및 검증 연구가 부족한 실정이다. 본 연구에서는 만경강 상류의 시험유역에 직접 계측방법인 수위-유량관계법, 초음파법, 전자파법을 적용하였고, 계측방법별로 산정된 유량자료간의 절대오차 비교를 통해 계측자료의 정확도를 비교 평가하였다. 점단위 산정유량 비교시 초음파법이 실측값에 가장 근사한 결과를 보였다. 연속적인 계측을 통해 일단위와 월단위의 총량을 비교하였고, 초음파법과 전자파법이 정확도가 높은 것으로 나타났다. 본 연구의 결과를 토대로 초음파법과 전자파법이 수위-유량관계법에 비해 비교적 높은 비용이 투입되는 것을 감안하여 하천수 사용시설의 중요도에 따라 적정한 직접 계측방법을 선정할 수 있기를 기대한다.

      • KCI등재

        농업용수 사용량 계측을 위한 전자파 표면유속계의 적용

        백종석,김치영,이기성,강현웅,송재현,Baek, Jongseok,Kim, Chiyoung,Lee, Kisung,Kang, Hyunwoong,Song, Jaehyun 한국수자원학회 2020 한국수자원학회논문집 Vol.53 No.12

        For integrated water management, it is essential to secure basic data such as the amount of agricultural water intake. The river water intake through the intake weir is carried out through the agricultural irrigation canal, and a method for measuring the quantity of water intake is required to suit the characteristics of the measuring points. In this study, the accuracy of the calculated flow data was determined by applying a microwave water surface current meter. The microwave water surface current meter is a method of calculating surface velocity using doppler effect, which is mainly used in high-velocities situations such as flood. Surface velocity is difficult to represent the average velocity of the entire section at low dicharges or high wind speeds, it is considered to be low in continuous utilization throughout the year, and it is necessary to verify whether the measurement using an microwave water surface curren meter is appropriate in agricultural irrigation canal. The data measured with an microwave water surface curren meter were compared with the actual flow data to calculate the intake data in agricultural irrigation canal. In agricultural irrigation canal, the low-level discharge calculated using an microwave water surface current meter at a minimum velocity of about 0.3 m/s and a minimum discharge of about 1.0 m3/s or higher was found to have a high tendency and accuracy compared to the standard discharge, especially when the high discharge was high. Although effective results can be obtained in terms of quantity at low discharge, it is deemed that subsequent studies are needed to calculate the average discharge of the cross section at low discharge, given that the trend of data is unstable. Through this study, it is suggested that it is appropriate to calculate the amount of water intake through the microwave water surface current meter in artificial waterways with a certain discharge or higher, so it is expected to be widely distributed as a method for measuring river water intake.

      • UTM의 고속화된 계측 처리 및 데이터 모니터링 시스템 설계

        오영모 ( Youngmo Oh ),김동현 ( Donghyun Kim ),정성모 ( Sungmo Jung ),임효영 ( Hyoyoung Leem ),근소걸 ( Sogeol Geun ),양석 ( Shuo Yang ),임재현 ( Jaehyun Lim ),김치영 ( Chiyoung Kim ),김석수 ( Seoksoo Kim ) 한국정보처리학회 2014 한국정보처리학회 학술대회논문집 Vol.21 No.1

        시스템은 자발성, 자율성, 사회성, 반응성을 갖는 독립된 프로그램인 에이전트를 조합하여 구성되는 시스템으로 일반 사용자에게 편리하고 자연수러운 메타포를 제공한다. 그러나 개발자 측면에서는 에이전트 시스템에서 요구하는 각종 기능 및 제약규칙...

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼