    시스템 에어컨의 냉난방 성능에 대한 비교 실험연구 = Experimental Study on the Cooling and Heating Characteristics of System A/C

    한글로보기

    https://www.riss.kr/link?id=E805119

    • 0

      상세조회
    • 0

      다운로드
    서지정보 열기
    • 내보내기
    • 내책장담기
    • 공유하기
    • 오류접수

    부가정보

    다국어 초록 (Multilingual Abstract) kakao i 다국어 번역

    In the present study, the heating and cooling characteristics of a system A/C using a digital scroll compressor and BLDC inverter compressor are investigated by the calorimeter using air enthalpy method. Cooling and heating capacities, power inputs and COPS are measured at the low, moderate, high loads under the cooling and heating standard conditions. At cooling conditions, the capacity and power input of the digital scroll system is larger than the inverter case, except high load range. At heating conditions, the capacity of the digital scroll method is a little larger than the inverter case, except high load range. Since power input is low, large COPS are measured at moderate and high load ranges. This shows that the digital scroll system compared with the inverter case has good energy consumption efficiency at moderate and high load ranges except low load range. And when the system A/C is operated under the cooling and heating standard conditions, COPs are nearly uniform at total load ranges.
    번역하기

    In the present study, the heating and cooling characteristics of a system A/C using a digital scroll compressor and BLDC inverter compressor are investigated by the calorimeter using air enthalpy method. Cooling and heating capacities, power inputs an...

    In the present study, the heating and cooling characteristics of a system A/C using a digital scroll compressor and BLDC inverter compressor are investigated by the calorimeter using air enthalpy method. Cooling and heating capacities, power inputs and COPS are measured at the low, moderate, high loads under the cooling and heating standard conditions. At cooling conditions, the capacity and power input of the digital scroll system is larger than the inverter case, except high load range. At heating conditions, the capacity of the digital scroll method is a little larger than the inverter case, except high load range. Since power input is low, large COPS are measured at moderate and high load ranges. This shows that the digital scroll system compared with the inverter case has good energy consumption efficiency at moderate and high load ranges except low load range. And when the system A/C is operated under the cooling and heating standard conditions, COPs are nearly uniform at total load ranges.

    더보기

    목차 (Table of Contents)

    • 1. 서론
    • 2. 실험장치 및 실험방법
    • 2.1. 실험장치
    • 2.2. 실험방법
    • 3. 실험결과 및 고찰
    • 1. 서론
    • 2. 실험장치 및 실험방법
    • 2.1. 실험장치
    • 2.2. 실험방법
    • 3. 실험결과 및 고찰
    • 3.1. 냉방표준조건
    • 3.2. 난방표준조건
    • 4. 결론
    • 후기
    • 참고문헌
    더보기

    분석정보

    View

    상세정보조회

    0

    Usage

    원문다운로드

    0

    대출신청

    0

    복사신청

    0

    EDDS신청

    0

    동일 주제 내 활용도 TOP

    더보기

    이 자료와 함께 이용한 RISS 자료

    나만을 위한 추천자료

    해외이동버튼