RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재 SCOPUS

      Harris-Galante 무시멘트 비구 부품과 동반 사용된 무시멘트 대퇴 사입물 주위의 골내막 골용해 = Endosteal osteolysis about uncemented femoral components associated with Harris-Galante uncemented metal backed cup

      한글로보기

      https://www.riss.kr/link?id=A75593107

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Authors reviewed 159 cases of total hip arthroplasty which had used uncemented femoral components associated with Harris-Galante uncemented metal backed acetabular component and followed more than 1 year at least to identify overall incidence of osteo...

      Authors reviewed 159 cases of total hip arthroplasty which had used uncemented femoral components associated with Harris-Galante uncemented metal backed acetabular component and followed more than 1 year at least to identify overall incidence of osteolysis, incidence of osteolysis according to type of implant, time of first noted, radiographic distribution of osteolysis with its shape and size and correlation between osteolysis and relevant factors. The results were followings: 1) Overall incidence of femoral endosteal osteolysis in the use of three kind of uncemented femoral components associated with Harris Galente, uncemedted metal backed acetabular component was 6.3% 2) Osteolysis was first noted radiographically at 12 to 55 months(mean, 27months) postoperatively. 3) In most patients, osteolysis occurred at Zone 2, 3,5, 6 on AP radiograph and Zone 3,5,6 on lateral radiograph, where was distal to porous pad. 4) Mean liner wear rate in patient with osteolysis was 0.46 mm/year, which was higher than that reported previously and mean wear rate in cases with progression of osteolysis was higher than that without progression of osteolysis. 5) No correlation could be found between thickeness of polyethylene liner and osteolysis.

      더보기

      동일학술지(권/호) 다른 논문

      동일학술지 더보기

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼