RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재 SCIE SCOPUS

      Short and Long RC Columns with Internal WWM Reinforcement under Concentric and Eccentric Compression

      한글로보기

      https://www.riss.kr/link?id=A108593715

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Recently, various types of steel meshes were used as additional internal reinforcement for improving the confinement, ductility, and strength of the reinforced concrete (RC) columns. In this experimental study, a welded wire mesh (WWM) layer was used ...

      Recently, various types of steel meshes were used as additional internal reinforcement for improving the confinement, ductility, and strength of the reinforced concrete (RC) columns. In this experimental study, a welded wire mesh (WWM) layer was used as an internal reinforcement in addition to the traditional steel reinforcement (longitudinal bars and transverse ties) for short and long RC columns under concentric and eccentric compression. Thirty-six square RC columns with two slenderness ratios λ (height to width ratio) of 9 and 18 were tested under compression with eccentricity ratios e/t (eccentricity to section thickness ratio) of 0, 0.13, and 0.26. The reference columns were traditionally reinforced with longitudinal steel bars and transverse ties with a reference volumetric ratio ρr of 0.44%. The other columns comprised a WWM layer wrapped outside the ties whose volumetric ratio ranged from 0.22% to 0.44%. The results demonstrated that the columns reinforced with a WWM layer in addition to traditional reinforcement showed an improvement in ductility and strength compared to those reinforced with longitudinal bars and transverse ties only. A WWM layer increased the ultimate load of the columns comprising ρr ties by approximately 16% and 9% for short and long columns, respectively. These improvements were proportional to the ties volumetric ratio.

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼