RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재

      치과용 CAD/CAM 전용 세라믹기반 하이브리드 레진 수복물의 변연 적합 연구 = A study on marginal fit of the ceramic-based hybrid resin restoration for dental CAD/CAM systems

      한글로보기

      https://www.riss.kr/link?id=A107080989

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Purpose: This study aimed to assess and compare the marginal fit of ceramic-based hybrid resin restoration (HYB) and zirconia restoration (ZIR) for dental computer-aided design/computer-aided manufacturing systems. Methods: A stainless steel master mo...

      Purpose: This study aimed to assess and compare the marginal fit of ceramic-based hybrid resin restoration (HYB) and zirconia restoration (ZIR) for dental computer-aided design/computer-aided manufacturing systems. Methods: A stainless steel master model was produced. The impression was first made with silicone, and then stone working models were produced. A total of twenty restorations were fabricated with two different materials: ZIR and HYB. The silicone film thickness of the marginal gap was measured using a digital microscope; digital photos were taken at a magnification of ×160, and then analyzed using a measurement software. The values of the result were evaluated with the independent-sample t-test (α=0.05). All statistical analyses were performed with a statistical software. Results: The mean values for the marginal gap was 37.14±2.96 ㎛ for HYB, compared with 40.37±5.26 ㎛ for ZIR. No significant difference was found between ZIR and HYB (p=0.107). Conclusion: As a result, the marginal fit of the restoration fabricated using the hybrid resin was better than that of the restoration fabricated using zirconia. Also, the marginal fit of all groups was below the clinical acceptable range of 120 ㎛. Thus, HYB for dental CAD/CAM system in this study is expected to be suitable for clinical use in dentistry.

      더보기

      참고문헌 (Reference)

      1 Assif D, "The flow of zinc phosphate cement under a full-coverage restoration and its effect on marginal adaptation according to the location of cement application" 18 : 765-774, 1987

      2 McLean JW, "The estimation of cement film thickness by an in vivo technique" 131 : 107-111, 1971

      3 Tuntiprawon M, "The effect of cement thickness on the fracture strength of all-ceramic crowns" 40 : 17-21, 1995

      4 Lofstrom LH, "Scanning electron microscopic evaluation of clinically cemented cast gold restorations" 61 : 664-669, 1989

      5 Shofu, "SHOFU block HC · Disk HC" SHOFU Dental GmbH

      6 Seghi RR, "Relative flexural strength of six new ceramic materials" 8 : 239-246, 1995

      7 Goldman M, "Microleakage–full crowns and the dental pulp" 18 : 473-475, 1992

      8 Awada A, "Mechanical properties of resinceramic CAD/CAM restorative materials" 114 : 587-593, 2015

      9 Hung SH, "Marginal fit of porcelain-fused-to-metal and two types of ceramic crown" 63 : 26-31, 1990

      10 Beuer F, "Marginal and internal fits of fixed dental prostheses zirconia retainers" 25 : 94-102, 2009

      1 Assif D, "The flow of zinc phosphate cement under a full-coverage restoration and its effect on marginal adaptation according to the location of cement application" 18 : 765-774, 1987

      2 McLean JW, "The estimation of cement film thickness by an in vivo technique" 131 : 107-111, 1971

      3 Tuntiprawon M, "The effect of cement thickness on the fracture strength of all-ceramic crowns" 40 : 17-21, 1995

      4 Lofstrom LH, "Scanning electron microscopic evaluation of clinically cemented cast gold restorations" 61 : 664-669, 1989

      5 Shofu, "SHOFU block HC · Disk HC" SHOFU Dental GmbH

      6 Seghi RR, "Relative flexural strength of six new ceramic materials" 8 : 239-246, 1995

      7 Goldman M, "Microleakage–full crowns and the dental pulp" 18 : 473-475, 1992

      8 Awada A, "Mechanical properties of resinceramic CAD/CAM restorative materials" 114 : 587-593, 2015

      9 Hung SH, "Marginal fit of porcelain-fused-to-metal and two types of ceramic crown" 63 : 26-31, 1990

      10 Beuer F, "Marginal and internal fits of fixed dental prostheses zirconia retainers" 25 : 94-102, 2009

      11 Nakamura T, "Marginal and internal fit of Cerec 3 CAD/CAM all-ceramic crowns" 16 : 244-248, 2003

      12 Contrepois M, "Marginal adaptation of ceramic crowns : a systematic review" 110 : 447-454.e10, 2013

      13 Rahme HY, "In vitro evaluation of the"replica technique"in the measurement of the fit of Procera crowns" 9 : 25-32, 2008

      14 Daniel C, "Improving flexural strength of dental restorative ceramics using laser interference direct structuring" 91 : 3455-3457, 2008

      15 Rekow ED, "High-technology innovations–and limitations–for restorative dentistry" 37 : 513-524, 1993

      16 Petrini M, "Fabrication and characterization of biomimetic ceramic/polymer composite materials for dental restoration" 29 : 375-381, 2013

      17 Felton DA, "Effect of in vivo crown margin discrepancies on periodontal health" 65 : 357-364, 1991

      18 Holmes JR, "Considerations in measurement of marginal fit" 62 : 405-408, 1989

      19 Arocha MA, "Colour stainability of indirect CAD-CAM processed composites vs. conventionally laboratory processed composites after immersion in staining solutions" 42 : 831-838, 2014

      20 Al-Amleh B, "Clinical trials in zirconia : a systematic review" 37 : 641-652, 2010

      21 Laurent M, "Clinical evaluation of the marginal fit of cast crowns–validation of the silicone replica method" 35 : 116-122, 2008

      22 Lang NP, "Clinical and microbiological effects of subgingival restorations with overhanging or clinically perfect margins" 10 : 563-578, 1983

      23 Bindl A, "Clinical and SEM evaluation of all-ceramic chair-side CAD/CAM-generated partial crowns" 111 : 163-169, 2003

      24 Della Bona A, "Characterization of a polymer-infiltrated ceramic-network material" 30 : 564-569, 2014

      25 Poticny DJ, "CAD/CAM in-office technology: innovations after 25 years for predictable, esthetic outcomes" 141 (141): 5S-9S, 2010

      26 Tsitrou EA, "Brittleness index of machinable dental materials and its relation to the marginal chipping factor" 35 : 897-902, 2007

      27 Abdul Rahman Mohammed Saleh, "An in-vitro comparison of fracture resistance of three CAD/CAM Ceramic materials for fabricating Veneer" Elsevier BV 2020

      28 Wataha JC, "Alloys for prosthodontic restorations" 87 : 351-363, 2002

      29 Moon BH, "A study on the marginal fit of all-ceramic crown using CCD camera" 36 : 273-292, 1998

      30 Shin MH, "A study on improvements in manufatured technique of all ceramic crown" 23 : 9-15, 2002

      31 Choi UJ, "A study on how cyclic casting of base metal alloy for dental ceramic crown may effects upon its mechanical properties and microstructure" 25 : 9-20, 2003

      32 Sorensen JA, "A standardized method for determination of crown margin fidelity" 64 : 18-24, 1990

      33 Miyazaki T, "A review of dental CAD/CAM : current status and future perspectives from 20 years of experience" 28 : 44-56, 2009

      34 Holst S, "A new triplescan protocol for 3D fit assessment of dental restorations" 42 : 651-657, 2011

      35 Kim EH, "A comparative study on the fracture strength of esthetic porcelain crowns" 29 : 79-85, 2007

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2027 평가예정 재인증평가 신청대상 (재인증)
      2021-01-01 평가 등재학술지 유지 (재인증) KCI등재
      2020-07-01 학술지명변경 외국어명 : THE JOURNAL OF KOREAN ACADEMY OF DENTAL TECHNOLOGY -> Journal of Technologic Dentistry KCI등재
      2018-01-01 평가 등재학술지 선정 (계속평가) KCI등재
      2017-01-01 평가 등재후보학술지 유지 (계속평가) KCI등재후보
      2015-01-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      2013-12-01 평가 등재후보 탈락 (등재후보2차)
      2012-01-01 평가 등재후보 1차 FAIL (기타) KCI등재후보
      2010-01-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.13 0.13 0.14
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.19 0.23 0.285 0.03
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼