RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      Matrix Enhancement Effect: A Blessing or a Curse for Gas Chromatography? = Matrix Enhancement Effect: A Blessing or a Curse for Gas Chromatography?

      한글로보기

      https://www.riss.kr/link?id=A100013050

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract) kakao i 다국어 번역

      The matrix enhancement effect in gas chromatography (GC) has been a problem for the last decade as it results in unexpected high recovery. Most of the efforts, including the use of different types of injectors/matrix simplification procedure, and further clean-up associated with removing this effect was focused on equalizing the response of the standard in the solvent and matrix. However, after eliminating the matrix enhancement effect, the sensitivity of GC remained unchanged. But, GC sensitivity can be increased by utilizing this matrix effect originating from a matrix matched standard. Very few studies have highlighted utilizing the matrix effect but have rather advocated eliminating it. Analyte protectants (3-ethoxy-1, 2-propanediol, gulonolactone and sorbitol) have been introduced as an alternative for GC-mass spectroscopy (GC-MS) (not examined for other GC detectors), as they equalize the response without removing the matrix effect, and, hence, increase sensitivity. Versatile applications of analyte protectants are not observed in practice. The European guidelines recommend use of matrix matched standard calibration for residue measurements. As a result, numerous applications are available for matrix matched standards that compensate for the matrix effect. Moreover, the matrices (among them pepper leaf matrix) can act as a protectant for thermolabileanalytes in some cases. A lower detection limit should be achieved from the GC detector to comply with the maximum residue limits. Therefore, the matrix enhancement effect, which is considered a problem, can play an important role in lowering the detection limit by increasing the transfer of analyte from the injection port to the detector.
      번역하기

      The matrix enhancement effect in gas chromatography (GC) has been a problem for the last decade as it results in unexpected high recovery. Most of the efforts, including the use of different types of injectors/matrix simplification procedure, and furt...

      The matrix enhancement effect in gas chromatography (GC) has been a problem for the last decade as it results in unexpected high recovery. Most of the efforts, including the use of different types of injectors/matrix simplification procedure, and further clean-up associated with removing this effect was focused on equalizing the response of the standard in the solvent and matrix. However, after eliminating the matrix enhancement effect, the sensitivity of GC remained unchanged. But, GC sensitivity can be increased by utilizing this matrix effect originating from a matrix matched standard. Very few studies have highlighted utilizing the matrix effect but have rather advocated eliminating it. Analyte protectants (3-ethoxy-1, 2-propanediol, gulonolactone and sorbitol) have been introduced as an alternative for GC-mass spectroscopy (GC-MS) (not examined for other GC detectors), as they equalize the response without removing the matrix effect, and, hence, increase sensitivity. Versatile applications of analyte protectants are not observed in practice. The European guidelines recommend use of matrix matched standard calibration for residue measurements. As a result, numerous applications are available for matrix matched standards that compensate for the matrix effect. Moreover, the matrices (among them pepper leaf matrix) can act as a protectant for thermolabileanalytes in some cases. A lower detection limit should be achieved from the GC detector to comply with the maximum residue limits. Therefore, the matrix enhancement effect, which is considered a problem, can play an important role in lowering the detection limit by increasing the transfer of analyte from the injection port to the detector.

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼