This study has been carried out to investigate the variation of removal efficiencies with SOx/NOx concentrations and the improvement of removal efficiencies with additives addition. The results are summarized as follows ;
1. For the SOx cases, the re...
This study has been carried out to investigate the variation of removal efficiencies with SOx/NOx concentrations and the improvement of removal efficiencies with additives addition. The results are summarized as follows ;
1. For the SOx cases, the removal efficiencies of 95%, 95% and 90% were achieved at 300ppm, 1000ppm and 1500pm respectively with 15 Ca/S stoichiometric ratio in SDA-FF Process
2. For the NOx cases, the removal efficiencies of SDA were obtained extremely low levels. But the removal efficiencies of SDA-FF were achieved approximately 50% regardless of Ca/S stoichiometric rations and concentration loadings.
3. For the cases in variation of NOx removal efficiencies with additives addition, the improvement of removal efficiencies were obtained 5%, 10% by NaOH, NH₄Br respectively with 1.0 Ca/S stoichiometric ratio in SDA-FF.