RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      SCIE KCI등재 SCOPUS

      Validation protocol for whole-body dosimetry in an agricultural exposure study

      한글로보기

      https://www.riss.kr/link?id=A106232274

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Agricultural workers exposed to pesticides can experience adverse health impacts depending on toxicity and exposure amount. Whole-body dosimetry (WBD) is the most reliable, practical, and realistic method for measuring exposure. Since validation of an...

      Agricultural workers exposed to pesticides can experience adverse health impacts depending on toxicity and exposure amount. Whole-body dosimetry (WBD) is the most reliable, practical, and realistic method for measuring exposure. Since validation of analytical and experimental methodologies is critical for quantitative determination of exposure, we conducted a validation procedure to design an essential protocol for WBD exposure studies. Using the fungicide kresoxim-methyl, matrixmatched standards were prepared with various matrices including outer cloth, inner cloth, washing solution for gloves and hands, gauze, and glass fiber filter (IOM sampler) to determine the instrumental limit of quantitation for high-performance liquid chromatography (HPLC) (2 ng) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) (10 pg). Method limits of quantitation (MLOQ) were also set for HPLC (0.1 mg/L) and LC-MS/MS (0.005 mg/L). We observed good analysis repeatability (coefficient of variation < 6%), and the linearity of the calibration curves was reasonable ($r^2$ > 0.998) in the range of 0.001-10 mg/L in various matrices. Recovery tests were carried out at three levels of concentration (MLOQ, 10 MLOQ, and 100 MLOQ) and resulted in good recoveries (72.7-105.6%). We did not observe breakthrough of the compound in tests of holding capacity for glass fiber pesticide filters. The procedures established in the present study are applicable as an essential, comprehensive protocol for exposure assessment studies using WBD.

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼