      두 종류의 다른 작동유체가 ORC 시스템의 성능에 미치는 영향

      한글로보기

      https://www.riss.kr/link?id=A99667273

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      The organic Rankine Cycle (ORC) uses a kind of refrigerant as a working fluid that evaporates at relatively low temperature, as the Rankine Cycle uses superheated steam as the working fluid. A small scale ORC test bench was installed, and two differen...

      The organic Rankine Cycle (ORC) uses a kind of refrigerant as a working fluid that evaporates at relatively low temperature, as the Rankine Cycle uses superheated steam as the working fluid. A small scale ORC test bench was installed, and two different working fluids (R245fa and R134a) were injected into the test bench. The test bench was in operation with the two different working fluids under the same conditions. The effects against the system performance from the different working fluids were analysed, and root causes were identified. Other factors reflecting the power generation efficiency were also found. A conclusion was drawn, that R245fa makes the system perform better, than R134a.

      더보기

      목차 (Table of Contents)

      • Abstract
      • 1. 서론
      • 2. 실험적 고찰
      • 3. 결론
      • 참고문헌
      • Abstract
      • 1. 서론
      • 2. 실험적 고찰
      • 3. 결론
      • 참고문헌
      더보기

      참고문헌 (Reference)

      1 Vankeirsblick, I., "Organic Rankine Cycle as Efficient Alternative to Steam Cycle for Small Scale Power Generation" 2011

      2 Chang, H. S., "Interim Report on Development of Efficiency Assessment Technology for Secondary Power Generation Systems" KPU 7-23, 2012

      3 Korea Institute of Energy Research, "For the utilization of waste heat recovery Organic Rankine Cycle Development and Application Research(ⅲ)" Korea Institute of Energy Research 1991

      4 Park, H. S., "Development of 1MW ORganic Rankine Cycle System" 10 (10): 318-326, 2001

      5 Buijtenen, J. V., "Design, Developen and Operation of the Tri-O-Gen ORC Power Unit" Tri-O-Gen 2011

      1 Vankeirsblick, I., "Organic Rankine Cycle as Efficient Alternative to Steam Cycle for Small Scale Power Generation" 2011

      2 Chang, H. S., "Interim Report on Development of Efficiency Assessment Technology for Secondary Power Generation Systems" KPU 7-23, 2012

      3 Korea Institute of Energy Research, "For the utilization of waste heat recovery Organic Rankine Cycle Development and Application Research(ⅲ)" Korea Institute of Energy Research 1991

      4 Park, H. S., "Development of 1MW ORganic Rankine Cycle System" 10 (10): 318-326, 2001

      5 Buijtenen, J. V., "Design, Developen and Operation of the Tri-O-Gen ORC Power Unit" Tri-O-Gen 2011

      더보기

      동일학술지(권/호) 다른 논문

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2022 평가예정 계속평가 신청대상 (등재유지)
      2017-01-01 평가 우수등재학술지 선정 (계속평가)
      2013-01-01 평가 등재 1차 FAIL (등재유지) KCI등재
      2010-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2008-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2006-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2004-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2001-07-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      1999-01-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.8 0.8 0.62
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.51 0.44 0.622 0.03
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼