RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재 SCOPUS SCIE

      Pattern of microimplant displacement during maxillary skeletal expander treatment: A cone-beam computed tomography study

      한글로보기

      https://www.riss.kr/link?id=A108767584

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Objective: To analyze the microimplant (MI) displacement pattern on treatment with a maxillary skeletal expander (MSE) using cone-beam computed tomography (CBCT). Methods: Thirty-nine participants (12 males and 27 females; mean age, 18.2 ± 4.2 years)...

      Objective: To analyze the microimplant (MI) displacement pattern on treatment with a maxillary skeletal expander (MSE) using cone-beam computed tomography (CBCT). Methods: Thirty-nine participants (12 males and 27 females; mean age, 18.2 ± 4.2 years) were treated successfully with the MSE II appliance. Their pre- and post-expansion CBCT data were superimposed. The pre- and post-expansion anterior and posterior inter-MI angles, neck and apical inter-MI distance, plate angle, palatal bone thickness at the MI positions, and suture opening at the MI positions were measured and compared. Results: The jackscrew plate was slightly bent in both anterior and posterior areas. There was no significant difference in the extent of suture opening between the anterior and posterior MIs (P > 0.05). The posterior MI to hemiplate line was greater than that anteriorly (P < 0.05). The apical distance between the posterior MIs was greater than that anteriorly (P < 0.05). The palatal thickness at the anterior MIs was significantly greater than that posteriorly (P > 0.01). Conclusions: In the coronal plane, the angulation between the anterior MIs in relation to the jackscrew plate was greater than that between the posterior MIs owing to the differential palatal bone thickness.

      더보기

      동일학술지(권/호) 다른 논문

      동일학술지 더보기

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼