      결로방지를 위한 공용배기 활용 환기 시스템의 습도저감 성능 분석

      한글로보기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      In order to prevent condensation, it is necessary to remove water vapor through ventilation. In this study, we proposed a hybrid ventilation system in which natural ventilation and cen-tralized exhaust fan (VCE) ventilation systems are linked, and the...

      In order to prevent condensation, it is necessary to remove water vapor through ventilation. In this study, we proposed a hybrid ventilation system in which natural ventilation and cen-tralized exhaust fan (VCE) ventilation systems are linked, and then compared the air flow of the natural ventilation system and the VCE system using a Computational fluid dynamics (CFD) model. The possibility of condensation was analyzed according to the systems’ chang-es in temperature and relative humidity, and the temperature and the humidity of the ventila-tion systems were directly measured within apartment houses. The results revealed that the ventilation volume of the whole household measured at 0.15 ACH when the natural ventila-tion was applied, and 0.50 ACH when the VCE system was applied. The average indoor air temperature only decreased by 1℃ when VCE was applied, indicating a very slight differ-ence when compared to the natural ventilation system. In addition, the result of analyzing the relative humidity distribution shows that the local relative humidity exceeded 100%, and that condensation conditions were formed when the natural ventilation system was applied. How-ever, the relative humidity distribution was even, and less than 100%, when the VCE system was applied, indicating a low probability of condensation. The results of analyzing the dif-ferences in average indoor air temperature with the VCE system shows that the air tempera-ture was measured to be 1.9℃ lower in the living room, and 2.27℃ lower in the laundry room, the balcony, and the evacuation space, than the air temperatures achieved with the nat-ural ventilation system. As a result of measuring the levels of absolute humidity, the average absolute humidity with the shared exhaust ventilation system was lower by 44.56% in the liv-ing room, the laundry room, and the evacuation space, when compared to the humidity of the natural ventilation opening case. Therefore, the results revealed that the humidity reduction performance was improved when the shared exhaust ventilation system was applied, when compared to the natural ventilation system, which could be effective in the prevention of condensation.

      더보기

      목차 (Table of Contents)

      • Abstract
      • 1. 서론
      • 2. CFD를 통한 공용배기 활용 환기 시스템의 온습도 분포 분석
      • 3. 실증을 통한 공용배기 활용 환기 시스템의 습도저감 성능 분석
      • 4. 결론
      • Abstract
      • 1. 서론
      • 2. CFD를 통한 공용배기 활용 환기 시스템의 온습도 분포 분석
      • 3. 실증을 통한 공용배기 활용 환기 시스템의 습도저감 성능 분석
      • 4. 결론
      • References