      발전소 통합감시제어시스템의 MBC 개발 로직 실계통 적용

      한글로보기

      https://www.riss.kr/link?id=A99739472

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Because the existing control system has been operating for about 20 years, it is necessary to upgrade the system for stable and efficient operation. But, there is a difficulty in maintenance by difference of manufacturer of each main control systems f...

      Because the existing control system has been operating for about 20 years, it is necessary to upgrade the system for stable and efficient operation. But, there is a difficulty in maintenance by difference of manufacturer of each main control systems for boiler, turbine and generator. This developed IMCS(Integrated Monitoring and Control System) consists of more than 10,000 inputs and outputs for large scale thermal power plant. This paper consists of the development journey of IMCS MBC(mill and burner control) ; core binary protection & monitoring logic including prevention circuit of boiler explosion & implosion. In this project, the IMCS for boiler, turbine and generator was developed on basis of one communications platform. In this paper, the whole journey of development of IMCS MBC is dealt with designing software and hardware, coding application software, and validating software and hardware.

      더보기

      목차 (Table of Contents)

      • Abstract
      • 1. 서론
      • 2. 본론
      • 3. 결론
      • References
      • Abstract
      • 1. 서론
      • 2. 본론
      • 3. 결론
      • References
      더보기

      참고문헌 (Reference)

      1 Man-Su Shin, "Tae-An unit no.1 IMCS MBC Logic Validation Result Report" KEPCO RI 2011

      2 NFPA, "Standard for the prevention of furnace explosion /implosions in multiple burner boilers" NFPA 1995

      3 In-Kyu Choi, "Performance Validation Result Report for Application of IMCS" KEPCO RI 2012

      4 Man-Su Shin, "Functional Tests for MBC of IMCS by Simulator" 2012

      5 In-Kyu Choi, "Commissioning Result Report for IMCS of Tae-An Unit no.1" KEPCO RI 2013

      6 Man-Su Shin, "Anaysis of Equipment Qualification Tests for IMCS(Integrated Monitoring & Control System) in Thermal Power Plants" 2011

      1 Man-Su Shin, "Tae-An unit no.1 IMCS MBC Logic Validation Result Report" KEPCO RI 2011

      2 NFPA, "Standard for the prevention of furnace explosion /implosions in multiple burner boilers" NFPA 1995

      3 In-Kyu Choi, "Performance Validation Result Report for Application of IMCS" KEPCO RI 2012

      4 Man-Su Shin, "Functional Tests for MBC of IMCS by Simulator" 2012

      5 In-Kyu Choi, "Commissioning Result Report for IMCS of Tae-An Unit no.1" KEPCO RI 2013

      6 Man-Su Shin, "Anaysis of Equipment Qualification Tests for IMCS(Integrated Monitoring & Control System) in Thermal Power Plants" 2011

      더보기

      동일학술지(권/호) 다른 논문

      동일학술지 더보기

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2023 평가예정 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
      2020-01-01 평가 등재학술지 유지 (해외등재 학술지 평가) KCI등재
      2010-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2007-01-01 평가 학술지 통합 (기타) KCI등재
      2001-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.27 0.27 0.24
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.21 0.19 0.366 0.08
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼