      Ensuring the safety of baby bottle teats and kitchen tools made from rubber is critical. Therefore, the migration of N-nitrosamines and N-nitrosatable substances from 30 teats and 45 kitchen tools to artificial saliva was analyzed by liquid chromatography–tandem mass spectrometry.
      The method was validated by assessing the limits of detection (0.46–3.87 lg/kg), limits of quantification (1.38–11.73 lg/kg), and recoveries (86.3–108.6%) of seven compounds. Nitrosodimethylamine (NDMA), N-nitrosopiperidine, and N-nitrosomorpholine (NMOR) migrated from baby bottle teats at concentrations of not detected (ND) to 3.67 lg/kg. NDMA and NMOR concentrations ranged from ND to 1.72 lg/kg after migration from 45 rubber kitchen tools. N-nitrosatable substances ranged from ND to 42.16 lg/kg after migration from baby bottle teats but did not migrate from rubber kitchen tools. All tested products were considered safe for use, as N-nitrosamine and N-nitrosatable substance levels did not exceed the permitted management specifications.
      번역하기

      Ensuring the safety of baby bottle teats and kitchen tools made from rubber is critical. Therefore, the migration of N-nitrosamines and N-nitrosatable substances from 30 teats and 45 kitchen tools to artificial saliva was analyzed by liquid chromatogr...

      Ensuring the safety of baby bottle teats and kitchen tools made from rubber is critical. Therefore, the migration of N-nitrosamines and N-nitrosatable substances from 30 teats and 45 kitchen tools to artificial saliva was analyzed by liquid chromatography–tandem mass spectrometry.
      The method was validated by assessing the limits of detection (0.46–3.87 lg/kg), limits of quantification (1.38–11.73 lg/kg), and recoveries (86.3–108.6%) of seven compounds. Nitrosodimethylamine (NDMA), N-nitrosopiperidine, and N-nitrosomorpholine (NMOR) migrated from baby bottle teats at concentrations of not detected (ND) to 3.67 lg/kg. NDMA and NMOR concentrations ranged from ND to 1.72 lg/kg after migration from 45 rubber kitchen tools. N-nitrosatable substances ranged from ND to 42.16 lg/kg after migration from baby bottle teats but did not migrate from rubber kitchen tools. All tested products were considered safe for use, as N-nitrosamine and N-nitrosatable substance levels did not exceed the permitted management specifications.

      더보기

      참고문헌 (Reference)

      1 MFDS, "Standards and specifications for food utensil, containers and packages"

      2 ASTM, "Standard specification for volatile N-nitrosamine levels in rubber nipples on pacifiers. F1313-90"

      3 Reche F, "Optimization of parameters for the supercritical fluid extraction in the determination of N-nitrosamines in rubbers" 963 : 419-426, 2002

      4 Challis BC, "Nutrition and nitrosamine formation" 44 : 95-100, 1985

      5 Nrishinha PS, "Nitrosamines in baby bottle nipples and pacifiers: occurrence, migration, and effect of infant formulas and fruit juices on in vitro formation of nitrosamines under simulated gastric conditions" 33 : 428-433, 1985

      6 Sen NP, "Nitrosamines in baby bottle nipples and pacifiers: Occurrence, migration, and effect of infant formulas and fruit juices on in vitro formation of nitrosamines under simulated gastric conditions" 33 : 428-433, 1985

      7 Bouma K, "Migration of N-nitrosamines, N-nitrosatable substances and 2-mercaptobenzthiazol from baby bottle teats and soothers: a Dutch retail survey" 20 : 853-858, 2003

      8 Bouma K, "Migration of N-nitrosamines, N-nitrosatable substances and 2-mercaptobenzthiazol from baby bottle teats and soothers: a Dutch retail survey" 20 : 853-858, 2003

      9 IARC, "List of Classifications" International Agency Research on Cancer

      10 Sung JH, "Liquid chromatography-tandem mass spectrometry determination of N-nitrosamines released from rubber or elastomer teats and soothers" 27 : 1745-1754, 2010

      1 MFDS, "Standards and specifications for food utensil, containers and packages"

      2 ASTM, "Standard specification for volatile N-nitrosamine levels in rubber nipples on pacifiers. F1313-90"

      3 Reche F, "Optimization of parameters for the supercritical fluid extraction in the determination of N-nitrosamines in rubbers" 963 : 419-426, 2002

      4 Challis BC, "Nutrition and nitrosamine formation" 44 : 95-100, 1985

      5 Nrishinha PS, "Nitrosamines in baby bottle nipples and pacifiers: occurrence, migration, and effect of infant formulas and fruit juices on in vitro formation of nitrosamines under simulated gastric conditions" 33 : 428-433, 1985

      6 Sen NP, "Nitrosamines in baby bottle nipples and pacifiers: Occurrence, migration, and effect of infant formulas and fruit juices on in vitro formation of nitrosamines under simulated gastric conditions" 33 : 428-433, 1985

      7 Bouma K, "Migration of N-nitrosamines, N-nitrosatable substances and 2-mercaptobenzthiazol from baby bottle teats and soothers: a Dutch retail survey" 20 : 853-858, 2003

      8 Bouma K, "Migration of N-nitrosamines, N-nitrosatable substances and 2-mercaptobenzthiazol from baby bottle teats and soothers: a Dutch retail survey" 20 : 853-858, 2003

      9 IARC, "List of Classifications" International Agency Research on Cancer

      10 Sung JH, "Liquid chromatography-tandem mass spectrometry determination of N-nitrosamines released from rubber or elastomer teats and soothers" 27 : 1745-1754, 2010

      11 Feng D, "Extraction, confirmation, and screening of non-target compounds in silicone rubber teats by purge-and-trap and SPME combined with GC-MS" 56 : 91-98, 2016

      12 Feng D, "Evaluation of simulant migration of volatile nitrosamines from Latex Gloves and Balloons by HS-SPME-GC-MS" 50 : 733-738, 2012

      13 Heavy DC, "Estimation of volatile N-nitrosamines in rubber nipples for babies' bottles" 20 : 939-944, 1982

      14 CEN, "EN 12868: Child use and care articles-methods for determining the release of N-nitrosamines and N-nitrosatable Substances from elastomer or rubber teats and soothers"

      15 Niessner G, "Direct comparison of solid-phase extraction and solid-phase microextraction for the gas chromatographicdetermination of dibenzylamine in artificial saliva leachates from baby bottle teats" 414 : 133-140, 2000

      16 Masahiro T, "Determination of volatile N-nitrosamines in rubber nipples by gas chromatography using thermal energy analyzer" 2 : 577-580, 1986

      17 Feng D, "Detection and toxicity assessment of nitrosamines migration from latex gloves in the Chinese market" 212 : 533-540, 2009

      18 EU, "Commission Directive 93/11/EEC. Concerning the release of the N-nitrosamines and N-nitrosatable substances from elastomer or rubber teats and soothers" L93/37 : 1993

      19 European Committee for Standardization, "Child use and care articles. Methods for determining the release of N-nitrosamines and N-nitrosatable substances from elastomer or rubber teats and soothers. EN 12868"

      20 AOAC, "Appendix K, Part I: Guidelines for single laboratory validation of chemical methods for dietary supplements and botanicals"

      21 Motoh M, "Analysis of N-nitrosamine migration from rubber teats and soothers" 4 : 277-285, 2013

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2023 평가예정 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
      2020-01-01 평가 등재학술지 유지 (해외등재 학술지 평가) KCI등재
      2010-11-23 학회명변경 영문명 : Korean Society Of Food Science And Biotechnology -> Korean Society of Food Science and Technology KCI등재
      2010-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2008-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2006-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2004-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2001-07-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      1999-01-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.75 0.17 0.56
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.49 0.43 0.364 0.06
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼