RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      SCI SCIE SCOPUS

      64-Channel Second-Order Planar Gradiometer System for Magnetocardiograms

      한글로보기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      <P>A 64-channel planar gradiometer system was developed to measure magnetocardiogram (MCG) signals. The planar gradiometers are second-order planar gradiometers with a baseline of 50 mm, fabricated from Nb thin films on Si wafers using thin film processes. The SQUIDs were fabricated from Nb/Al-oxide/Nb junctions, and a double relaxation oscillation SQUID (DROS) scheme was used to have a large flux-to-voltage transfer, typically about 1 mV/Phi<SUB>0</SUB>. The planar gradiometers were arranged to measure magnetic field components tangential to the chest surface, which has a field distribution peak just above the current dipole. The diameter of the sensor coverage area is 190 mm, which was proved to be large enough to provide MCG field distribution in a single measurement. Inside a thin-wall shield room, the white noise level of the planar gradiometer system is about 8 fTradicHz. The 64-channel system was operated in a thin-wall shield room, and MCG signals were measured.</P>
      번역하기

      <P>A 64-channel planar gradiometer system was developed to measure magnetocardiogram (MCG) signals. The planar gradiometers are second-order planar gradiometers with a baseline of 50 mm, fabricated from Nb thin films on Si wafers using thin film...

      <P>A 64-channel planar gradiometer system was developed to measure magnetocardiogram (MCG) signals. The planar gradiometers are second-order planar gradiometers with a baseline of 50 mm, fabricated from Nb thin films on Si wafers using thin film processes. The SQUIDs were fabricated from Nb/Al-oxide/Nb junctions, and a double relaxation oscillation SQUID (DROS) scheme was used to have a large flux-to-voltage transfer, typically about 1 mV/Phi<SUB>0</SUB>. The planar gradiometers were arranged to measure magnetic field components tangential to the chest surface, which has a field distribution peak just above the current dipole. The diameter of the sensor coverage area is 190 mm, which was proved to be large enough to provide MCG field distribution in a single measurement. Inside a thin-wall shield room, the white noise level of the planar gradiometer system is about 8 fTradicHz. The 64-channel system was operated in a thin-wall shield room, and MCG signals were measured.</P>

      더보기

      동일학술지(권/호) 다른 논문

      동일학술지 더보기

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼