RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      SCOPUS KCI등재

      Chamber 크기와 검사 시약의 양이 피부 자극반응에 미치는 영향 = The Effect of Chamber Size and Vulume of Test Solution on Cutaneous IrritationChamber 크기와 검사 시약의 양이 피부 자극반응에 미치는 영향

      한글로보기

      https://www.riss.kr/link?id=A3288144

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Background: There are some variables including chamber size in irritant patch test responses. Several non-invasive bidengineering methods for quantifying and obtaining information have been developed in recent decades. Objective : Our study was done to compare the effect of chamber size and the volume effect on the irritation potential of 1% SLS solution. Methods : Patches with 1% sodium lauryl sulfate(SLS) solution were applied to the volar forearm of 14 healthy volunteers for 24 h. Finn chambers with 8mm(20ul), 12mm(60pl), 18mm(80ul, 200ul) inner diameters were used. Visual score and transepidermal water loss (TEWL) were measured at 30 min after removal of the patches, and every 24 h up to 4 days. Results : The results are summarized as follows. 1. Visual scores were 0.18+0.32(8mm), 0.75+0.33(12mm) and 0.64+0.41(18mm) at 24 h after removal of 1% SLS and were 0.11+0.29, 0.50+0.34 and 0.25+0.26 on 4 days after removal. They were inereased 30 min and 24 h after removal and decreased towards normal 4 days after removal. By chamber size, the skin response with the large Finn chamber(12mm) increased more significantly than with the small Finn chamber(8mm). However, there were no significant differences in skin response between large and extralarge Finn chambers(18mm). 2. TEWL values were 11.86+4.09, 23.05+6.1l and 22.24+7.54g/m/h at 30 min after removal and were 9.37+2.30, 1..49+3.08 and 14.56+5.00g/m/h on 4 days after removal. They were increased 30 min after removal and decreased towards normal 4 days after removal. By chamber size, their results were the same as visual scores. 3. By visual score and TEWL, the skin response with 200pl of 1% SLS increased more significantly than 80pl in the extralarge Finn chamber. Conclusion : The small Finn chamber may be too small to elicit sufficient cutaneous irritation for evaluation. The large Finn chamber having larger test areas may be suitable to yield positive reactions to certain irritants. Also, the quantity of test solution per mm skin may be of importance for the skin response. (KOr J Dermatol 1997;35(3): 424-430)
      번역하기

      Background: There are some variables including chamber size in irritant patch test responses. Several non-invasive bidengineering methods for quantifying and obtaining information have been developed in recent decades. Objective : Our study was done t...

      Background: There are some variables including chamber size in irritant patch test responses. Several non-invasive bidengineering methods for quantifying and obtaining information have been developed in recent decades. Objective : Our study was done to compare the effect of chamber size and the volume effect on the irritation potential of 1% SLS solution. Methods : Patches with 1% sodium lauryl sulfate(SLS) solution were applied to the volar forearm of 14 healthy volunteers for 24 h. Finn chambers with 8mm(20ul), 12mm(60pl), 18mm(80ul, 200ul) inner diameters were used. Visual score and transepidermal water loss (TEWL) were measured at 30 min after removal of the patches, and every 24 h up to 4 days. Results : The results are summarized as follows. 1. Visual scores were 0.18+0.32(8mm), 0.75+0.33(12mm) and 0.64+0.41(18mm) at 24 h after removal of 1% SLS and were 0.11+0.29, 0.50+0.34 and 0.25+0.26 on 4 days after removal. They were inereased 30 min and 24 h after removal and decreased towards normal 4 days after removal. By chamber size, the skin response with the large Finn chamber(12mm) increased more significantly than with the small Finn chamber(8mm). However, there were no significant differences in skin response between large and extralarge Finn chambers(18mm). 2. TEWL values were 11.86+4.09, 23.05+6.1l and 22.24+7.54g/m/h at 30 min after removal and were 9.37+2.30, 1..49+3.08 and 14.56+5.00g/m/h on 4 days after removal. They were increased 30 min after removal and decreased towards normal 4 days after removal. By chamber size, their results were the same as visual scores. 3. By visual score and TEWL, the skin response with 200pl of 1% SLS increased more significantly than 80pl in the extralarge Finn chamber. Conclusion : The small Finn chamber may be too small to elicit sufficient cutaneous irritation for evaluation. The large Finn chamber having larger test areas may be suitable to yield positive reactions to certain irritants. Also, the quantity of test solution per mm skin may be of importance for the skin response. (KOr J Dermatol 1997;35(3): 424-430)

      더보기

      동일학술지(권/호) 다른 논문

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼