RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      SCOPUS KCI등재

      배란유도주기에 따른 초음파검사와 기초체온표의 비교분석 = A Comparative Analysis of Basal Body Temperature to Ultrasound, as a Method of Ovulation Detection in Induced Ovulatory Menstrual Cycles

      한글로보기

      https://www.riss.kr/link?id=A100815773

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract) kakao i 다국어 번역

      Four points on the basal body temperature (B.B.T.) curve was correlated with the estimated time of ovulation, as determined by serial ultrasound in 50 induced menstrual cycles from 22 subjects. The time of ovulation was estimated by measuring the maximal diameter of follicles and observing the morphologic changes within the ovary from follicle to corpus luteum. The results were as following; 1. The diameter of the follicle measured at the day before disappearance was 21.1 mm on an average (S.D.: 2.14). The average follicular growth for 4 days before ovulation was measured at a rate of 2.8 mm/day, and rapid growth of follicle was observed 3.1 mm/day at the day before. 2. The changes associated with rupture of the follicles were the followings, in order of frequency; decrease in size(94%), disappearance of follicles(64%), fluid in the Cul-de-Sac(26%) and increased internal echoes(16%). 3. Only 20 of 50 cycles, exhibited a BBT dip and correlated with the estimated time of ovulation by ultrasound in 2 of which cases(10%). BBT nadir, 30 of 50 cycles, correlated in 5(16.7%). The first day of hyperthermic plateau(FDHP) and BBT coverline was exhibited in all cycles, correlated in 41(82%) and 35(70%) cases. 4. The relationship between the diameter of dominant dominant follicle, measured by ultrasound, and the basal body temperature curve were as following. During cycles in which dip was observed on the BBT curve, the follicular diameter were 10.5${\pm}$2.12 mm on 4 days prior to the point (D-4), and 12.5${\pm}$2.12 mm (D-3), 15.5${\pm$2.12 mm (D-2), 17.0${\pm}$1.41 mm (D-1) and 21.5${\pm}$2.12 mm just prior to the dip (D-0). In the nadir; 9.6${\pm}$1.67 mm (N-4), 12.8${\pm}$1.79 mm (N-3), 16.2${\pm}$1.92 mm (N-2), 18.2${\pm}$2.17 mm (N-1) and 21.4${\pm}$2.61 mm (N-0). In the First day of Hyperthemic Plateau (FDHP); 9.8${\pm}$1.36 mm (F-4), 12.4${\pm}$1.41 mm (F-3),15.1${\pm}$1.57 mm (F-2), 18.1${\pm}$1.67 mm (F-1) and 21.2${\pm}$2.25 mm (F-0). In the BBT coverline endopint; 9.9${\pm}$.39 mm (C-4), 12.5 ${\pm}$1.44 mm (C-3), 15.2${\pm}$1.64 mm (C-2), 18.0 ${\pm}$1.69 mm (C-1), and 21.2${\pm}$2.31 mm (C-0). 5. The relationship between the ultrasonographic signs of ovulation and the basal body temperature curve were as following. The BBT dip correlated with the ovulation in 2 cases, which revealed decrease in follicular diameter (100%), fluid pattem in the Cul-de-Sac (1 case, 50%) and complete disappearance of follicle (1 case, 50%). In the nadir (5 cases); the ultrasonographic signs of ovulation were decrease in follicular diameter (5 cases, 100%), fluid pattern in the Cul-de-Sac (1 case, 20%) and complete disappearance of follicle (3 cases, 60%). In the First day of Hyperthermic Plateau (41 cases); decrease in follicular diameter (40 cases, 97.6%), fluid pattern in the Cul-de-Sac (11 cases, 26.8%), appearance of internal echo and thickening of the wall (6 cases, 14.6%) and com plete disappearance of follicle (28 cases, 68.3%). In the BBT coverline endpoint (35 cases); decrease in follicular diameter (33 cases, 94.3%), fluid pattern in the Cul-de Sac (9 cases, 25.7%), appearance of internal echo and thickening of the wall (5 cases 14.3%) and complete disappearance of follicle (20 cases, 57.1%).
      번역하기

      Four points on the basal body temperature (B.B.T.) curve was correlated with the estimated time of ovulation, as determined by serial ultrasound in 50 induced menstrual cycles from 22 subjects. The time of ovulation was estimated by measuring the maxi...

      Four points on the basal body temperature (B.B.T.) curve was correlated with the estimated time of ovulation, as determined by serial ultrasound in 50 induced menstrual cycles from 22 subjects. The time of ovulation was estimated by measuring the maximal diameter of follicles and observing the morphologic changes within the ovary from follicle to corpus luteum. The results were as following; 1. The diameter of the follicle measured at the day before disappearance was 21.1 mm on an average (S.D.: 2.14). The average follicular growth for 4 days before ovulation was measured at a rate of 2.8 mm/day, and rapid growth of follicle was observed 3.1 mm/day at the day before. 2. The changes associated with rupture of the follicles were the followings, in order of frequency; decrease in size(94%), disappearance of follicles(64%), fluid in the Cul-de-Sac(26%) and increased internal echoes(16%). 3. Only 20 of 50 cycles, exhibited a BBT dip and correlated with the estimated time of ovulation by ultrasound in 2 of which cases(10%). BBT nadir, 30 of 50 cycles, correlated in 5(16.7%). The first day of hyperthermic plateau(FDHP) and BBT coverline was exhibited in all cycles, correlated in 41(82%) and 35(70%) cases. 4. The relationship between the diameter of dominant dominant follicle, measured by ultrasound, and the basal body temperature curve were as following. During cycles in which dip was observed on the BBT curve, the follicular diameter were 10.5${\pm}$2.12 mm on 4 days prior to the point (D-4), and 12.5${\pm}$2.12 mm (D-3), 15.5${\pm$2.12 mm (D-2), 17.0${\pm}$1.41 mm (D-1) and 21.5${\pm}$2.12 mm just prior to the dip (D-0). In the nadir; 9.6${\pm}$1.67 mm (N-4), 12.8${\pm}$1.79 mm (N-3), 16.2${\pm}$1.92 mm (N-2), 18.2${\pm}$2.17 mm (N-1) and 21.4${\pm}$2.61 mm (N-0). In the First day of Hyperthemic Plateau (FDHP); 9.8${\pm}$1.36 mm (F-4), 12.4${\pm}$1.41 mm (F-3),15.1${\pm}$1.57 mm (F-2), 18.1${\pm}$1.67 mm (F-1) and 21.2${\pm}$2.25 mm (F-0). In the BBT coverline endopint; 9.9${\pm}$.39 mm (C-4), 12.5 ${\pm}$1.44 mm (C-3), 15.2${\pm}$1.64 mm (C-2), 18.0 ${\pm}$1.69 mm (C-1), and 21.2${\pm}$2.31 mm (C-0). 5. The relationship between the ultrasonographic signs of ovulation and the basal body temperature curve were as following. The BBT dip correlated with the ovulation in 2 cases, which revealed decrease in follicular diameter (100%), fluid pattem in the Cul-de-Sac (1 case, 50%) and complete disappearance of follicle (1 case, 50%). In the nadir (5 cases); the ultrasonographic signs of ovulation were decrease in follicular diameter (5 cases, 100%), fluid pattern in the Cul-de-Sac (1 case, 20%) and complete disappearance of follicle (3 cases, 60%). In the First day of Hyperthermic Plateau (41 cases); decrease in follicular diameter (40 cases, 97.6%), fluid pattern in the Cul-de-Sac (11 cases, 26.8%), appearance of internal echo and thickening of the wall (6 cases, 14.6%) and com plete disappearance of follicle (28 cases, 68.3%). In the BBT coverline endpoint (35 cases); decrease in follicular diameter (33 cases, 94.3%), fluid pattern in the Cul-de Sac (9 cases, 25.7%), appearance of internal echo and thickening of the wall (5 cases 14.3%) and complete disappearance of follicle (20 cases, 57.1%).

      더보기

      동일학술지(권/호) 다른 논문

      동일학술지 더보기

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼