RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재 SCIE SCOPUS

      The Role of Core Needle Biopsy for the Evaluation of Thyroid Nodules with Suspicious Ultrasound Features

      한글로보기

      https://www.riss.kr/link?id=A106011579

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Objective: Recent studies demonstrated that core needle biopsy (CNB) can effectively reduce the possibility of inconclusive results and prevent unnecessary diagnostic surgery. However, the effectiveness of CNB in patients with suspicious thyroid nodules has not been fully evaluated. This prospective study aimed to determine the potential of CNB to assess thyroid nodules with suspicious ultrasound (US) features.
      Materials and Methods: Patients undergoing CNB for thyroid nodules with suspicious features on US were enrolled between May and August 2016. Diagnostic performance and the incidence of non-diagnostic results, inconclusive results, conclusive results, malignancy, unnecessary surgery, and complications were analyzed. Subgroup analysis according to nodule size was performed. The risk factors associated with inconclusive results were evaluated using multivariate logistic regression analysis.
      Results: A total of 93 patients (102 thyroid nodules) were evaluated. All samples obtained from CNB were adequate for diagnosis. Inconclusive results were seen in 12.7% of cases. The diagnostic accuracy, sensitivity, specificity, positive predictive value, and negative predictive value for diagnosis of malignancy were 93.8%, 100%, 100%, 78.9%, and 95%, respectively. None of the patients underwent unnecessary surgery. The diagnostic performance was not significantly different according to nodule size. On multivariate logistic regression analysis, larger nodule size and shorter needle length were independent risk factors associated with inconclusive results.
      Conclusion: Samples obtained by CNB were sufficient for diagnosis in all cases and resulted in high diagnostic values and conclusive results in the evaluation of suspicious thyroid nodules. These findings indicated that CNB is a promising diagnostic tool for suspicious thyroid nodules.
      번역하기

      Objective: Recent studies demonstrated that core needle biopsy (CNB) can effectively reduce the possibility of inconclusive results and prevent unnecessary diagnostic surgery. However, the effectiveness of CNB in patients with suspicious thyroid nodul...

      Objective: Recent studies demonstrated that core needle biopsy (CNB) can effectively reduce the possibility of inconclusive results and prevent unnecessary diagnostic surgery. However, the effectiveness of CNB in patients with suspicious thyroid nodules has not been fully evaluated. This prospective study aimed to determine the potential of CNB to assess thyroid nodules with suspicious ultrasound (US) features.
      Materials and Methods: Patients undergoing CNB for thyroid nodules with suspicious features on US were enrolled between May and August 2016. Diagnostic performance and the incidence of non-diagnostic results, inconclusive results, conclusive results, malignancy, unnecessary surgery, and complications were analyzed. Subgroup analysis according to nodule size was performed. The risk factors associated with inconclusive results were evaluated using multivariate logistic regression analysis.
      Results: A total of 93 patients (102 thyroid nodules) were evaluated. All samples obtained from CNB were adequate for diagnosis. Inconclusive results were seen in 12.7% of cases. The diagnostic accuracy, sensitivity, specificity, positive predictive value, and negative predictive value for diagnosis of malignancy were 93.8%, 100%, 100%, 78.9%, and 95%, respectively. None of the patients underwent unnecessary surgery. The diagnostic performance was not significantly different according to nodule size. On multivariate logistic regression analysis, larger nodule size and shorter needle length were independent risk factors associated with inconclusive results.
      Conclusion: Samples obtained by CNB were sufficient for diagnosis in all cases and resulted in high diagnostic values and conclusive results in the evaluation of suspicious thyroid nodules. These findings indicated that CNB is a promising diagnostic tool for suspicious thyroid nodules.

      더보기

      참고문헌 (Reference)

      1 Shin JH, "Value of repeat ultrasound-guided fine-needle aspiration in nodules with benign cytological diagnosis" 47 : 469-473, 2006

      2 Kwak JY, "Value of US correlation of a thyroid nodule with initially benign cytologic results" 254 : 292-300, 2010

      3 Chung SR, "Ultrasound-pathology discordant nodules on core-needle biopsy: malignancy risk and management strategy" 27 : 707-713, 2017

      4 신정희, "Ultrasonography Diagnosis and Imaging-Based Management of Thyroid Nodules: Revised Korean Society of Thyroid Radiology Consensus Statement and Recommendations" 대한영상의학회 17 (17): 370-395, 2016

      5 Screaton NJ, "US-guided core-needle biopsy of the thyroid gland" 226 : 827-832, 2003

      6 Woo SH, "Thyroid nodules with repeat nondiagnostic cytologic results: the role of clinical and ultrasonographic findings" 39 : 1721-1727, 2015

      7 Yeon JS, "Thyroid nodules with initially nondiagnostic cytologic results:the role of core-needle biopsy" 268 : 274-280, 2013

      8 Choi SH, "Thyroid nodules with initially non-diagnostic, fine-needle aspiration results: comparison of core-needle biopsy and repeated fine-needle aspiration" 24 : 2819-2826, 2014

      9 Kim SY, "Thyroid nodules with benign findings at cytologic examination: results of long-term follow-up with US" 271 : 272-281, 2014

      10 Suh CH, "The role of core-needle biopsy as a first-line diagnostic tool for initially detected thyroid nodules" 26 : 395-403, 2016

      1 Shin JH, "Value of repeat ultrasound-guided fine-needle aspiration in nodules with benign cytological diagnosis" 47 : 469-473, 2006

      2 Kwak JY, "Value of US correlation of a thyroid nodule with initially benign cytologic results" 254 : 292-300, 2010

      3 Chung SR, "Ultrasound-pathology discordant nodules on core-needle biopsy: malignancy risk and management strategy" 27 : 707-713, 2017

      4 신정희, "Ultrasonography Diagnosis and Imaging-Based Management of Thyroid Nodules: Revised Korean Society of Thyroid Radiology Consensus Statement and Recommendations" 대한영상의학회 17 (17): 370-395, 2016

      5 Screaton NJ, "US-guided core-needle biopsy of the thyroid gland" 226 : 827-832, 2003

      6 Woo SH, "Thyroid nodules with repeat nondiagnostic cytologic results: the role of clinical and ultrasonographic findings" 39 : 1721-1727, 2015

      7 Yeon JS, "Thyroid nodules with initially nondiagnostic cytologic results:the role of core-needle biopsy" 268 : 274-280, 2013

      8 Choi SH, "Thyroid nodules with initially non-diagnostic, fine-needle aspiration results: comparison of core-needle biopsy and repeated fine-needle aspiration" 24 : 2819-2826, 2014

      9 Kim SY, "Thyroid nodules with benign findings at cytologic examination: results of long-term follow-up with US" 271 : 272-281, 2014

      10 Suh CH, "The role of core-needle biopsy as a first-line diagnostic tool for initially detected thyroid nodules" 26 : 395-403, 2016

      11 Nayar R, "The indeterminate thyroid fine-needle aspiration: experience from an academic center using terminology similar to that proposed in the 2007 National Cancer Institute Thyroid Fine Needle Aspiration state of the science conference" 117 : 195-202, 2009

      12 Yoon JH, "The diagnostic accuracy of ultrasound-guided fine-needle aspiration biopsy and the sonographic differences between benign and malignant thyroid nodules 3 cm or larger" 21 : 993-1000, 2011

      13 Bongiovanni M, "The Bethesda system for reporting thyroid cytopathology:a meta-analysis" 56 : 333-339, 2012

      14 Cibas ES, "The Bethesda system for reporting thyroid cytopathology" 19 : 1159-1165, 2009

      15 Ha EJ, "Sonographically suspicious thyroid nodules with initially benign cytologic results: the role of a core needle biopsy" 23 : 703-708, 2013

      16 Degirmenci B, "Sonographically guided fine-needle biopsy of thyroid nodules: the effects of nodule characteristics, sampling technique, and needle size on the adequacy of cytological material" 62 : 798-803, 2007

      17 Chehade JM, "Role of repeated fine-needle aspiration of thyroid nodules with benign cytologic features" 7 : 237-243, 2001

      18 Baloch Z, "Role of repeat fine-needle aspiration biopsy (FNAB)in the management of thyroid nodules" 29 : 203-206, 2003

      19 Na DG, "Role of core needle biopsy in the management of atypia/follicular lesion of undetermined significance thyroid nodules: comparison with repeat fine-needle aspiration in subcategory nodules" 4 : 189-196, 2015

      20 Orlandi A, "Repeated fineneedle aspiration of the thyroid in benign nodular thyroid disease: critical evaluation of long-term follow-up" 15 : 274-278, 2005

      21 정찬권, "Recent Advances in Core Needle Biopsy for Thyroid Nodules" 대한내분비학회 32 (32): 407-412, 2017

      22 Burke DR, "Quality improvement guidelines for percutaneous transhepatic cholangiography and biliary drainage" 14 (14): S243-S246, 2003

      23 Lewis CA, "Quality improvement guidelines for central venous access. The standards of practice committee of the Society of Cardiovascular & Interventional Radiology" 8 : 475-479, 1997

      24 정찬권, "Pathology Reporting of Thyroid Core Needle Biopsy: A Proposal of the Korean Endocrine Pathology Thyroid Core Needle Biopsy Study Group" 대한병리학회 49 (49): 288-299, 2015

      25 Richards ML, "Nondiagnostic thyroid fine-needle aspiration biopsies are no longer a dilemma" 196 : 398-402, 2008

      26 Moon HJ, "Malignancy risk stratification in thyroid nodules with benign results on cytology: combination of thyroid imaging reporting and data system and Bethesda system" 21 : 1898-1903, 2014

      27 Yassa L, "Long-term assessment of a multidisciplinary approach to thyroid nodule diagnostic evaluation" 111 : 508-516, 2007

      28 Chernyavsky VS, "Is one benign fine needle aspiration enough?" 19 : 1472-1476, 2012

      29 Hwang SH, "Imagingcytology correlation of thyroid nodules with initially benign cytology" 2014 : 491508-, 2014

      30 Kwak JY, "How to combine ultrasound and cytological information in decision making about thyroid nodules" 19 : 1923-1931, 2009

      31 Sclabas GM, "Fine-needle aspiration of the thyroid and correlation with histopathology in a contemporary series of 240 patients" 186 : 702-709, 2003

      32 Baier ND, "Fine-needle aspiration biopsy of thyroid nodules:experience in a cohort of 944 patients" 193 : 1175-1179, 2009

      33 Lew JI, "Fine needle aspiration of the thyroid: correlation with final histopathology in a surgical series of 797 patients" 213 : 188-194, 2011

      34 Choi SH, "Factors affecting inadequate sampling of ultrasound-guided fine-needle aspiration biopsy of thyroid nodules" 74 : 776-782, 2011

      35 Dean DS, "Endotext [Internet]" MDText.com, Inc 2015

      36 Choi YJ, "Differences in risk of malignancy and management recommendations in subcategories of thyroid nodules with atypia of undetermined significance or follicular lesion of undetermined significance: the role of ultrasound-guided core-needle biopsy" 24 : 494-501, 2014

      37 Sung JY, "Diagnostic accuracy of fine-needle aspiration versus coreneedle biopsy for the diagnosis of thyroid malignancy in a clinical cohort" 22 : 1564-1572, 2012

      38 백정환, "Current status of core needle biopsy of the thyroid" 대한초음파의학회 36 (36): 83-85, 2017

      39 Na DG, "Core-needle biopsy is more useful than repeat fine-needle aspiration in thyroid nodules read as nondiagnostic or atypia of undetermined significance by the Bethesda system for reporting thyroid cytopathology" 22 : 468-475, 2012

      40 나동규, "Core Needle Biopsy of the Thyroid: 2016 Consensus Statement and Recommendations from Korean Society of Thyroid Radiology" 대한영상의학회 18 (18): 217-237, 2017

      41 Moon WJ, "Benign and malignant thyroid nodules: US differentiation--multicenter retrospective study" 247 : 762-770, 2008

      42 Alexander EK, "Assessment of nondiagnostic ultrasoundguided fine needle aspirations of thyroid nodules" 87 : 4924-4927, 2002

      43 Gharib H, "American Association of Clinical Endocrinologists, Associazione Medici Endocrinologi, and EuropeanThyroid Association medical guidelines for clinical practice for the diagnosis and management of thyroid nodules" 16 (16): 1-43, 2010

      44 Haugen BR, "2015 American Thyroid Association management guidelines for adult patients with thyroid nodules and differentiated thyroid cancer: the American Thyroid Association guidelines task force on thyroid nodules and differentiated thyroid cancer" 26 : 1-133, 2016

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2023 평가예정 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
      2020-01-01 평가 등재학술지 유지 (해외등재 학술지 평가) KCI등재
      2016-11-15 학회명변경 영문명 : The Korean Radiological Society -> The Korean Society of Radiology KCI등재
      2010-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2007-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2006-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2003-01-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 1.61 0.46 1.15
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.93 0.84 0.494 0.06
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼