RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재

      임상뇌파검사의 일반적인 관행 = Common Practices in Clinical Electroencephalography

      한글로보기

      https://www.riss.kr/link?id=A107989775

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Electroencephalography (EEG) provides the most accurate and quickest diagnosis of epilepsy. It is also an important examination for the real-time evaluation of brain function and seizures, no matter where. In the field of epilepsy, it is appropriate for a clinical pathologist with considerable knowledge of EEG and clinical experience to perform the role of a Physician Assistant (PA). The electrode attachment method is based on the international 10-20 system. The EEG reading is mainly taken by longitudinal bipolar montage. However, a reading using only one montage may result in an error. Hence, two or more montages should be used for readings according to the clinical situation. In the EEG, electric potentials are seen as contour lines. The most important principle in EEG reading is under-reading, not over-reading. The higher the repetitions of the EEG recording, the greater the sensitivity of the reading. For a good reading, the EEG recording must be of good quality. So, the relationship between the neurologist and the EEG technician is very important. In the future, it is expected that the field of activities of the EEG technician with abundant EEG reading experience and clinical practical knowledge will be further expanded.
      번역하기

      Electroencephalography (EEG) provides the most accurate and quickest diagnosis of epilepsy. It is also an important examination for the real-time evaluation of brain function and seizures, no matter where. In the field of epilepsy, it is appropriate f...

      Electroencephalography (EEG) provides the most accurate and quickest diagnosis of epilepsy. It is also an important examination for the real-time evaluation of brain function and seizures, no matter where. In the field of epilepsy, it is appropriate for a clinical pathologist with considerable knowledge of EEG and clinical experience to perform the role of a Physician Assistant (PA). The electrode attachment method is based on the international 10-20 system. The EEG reading is mainly taken by longitudinal bipolar montage. However, a reading using only one montage may result in an error. Hence, two or more montages should be used for readings according to the clinical situation. In the EEG, electric potentials are seen as contour lines. The most important principle in EEG reading is under-reading, not over-reading. The higher the repetitions of the EEG recording, the greater the sensitivity of the reading. For a good reading, the EEG recording must be of good quality. So, the relationship between the neurologist and the EEG technician is very important. In the future, it is expected that the field of activities of the EEG technician with abundant EEG reading experience and clinical practical knowledge will be further expanded.

      더보기

      참고문헌 (Reference)

      1 김광덕, "측두엽간질에서 경막하 선형전극술:반구간 전파 시간과 수술 예후와의 연관성" 대한신경과학회 20 (20): 497-503, 2002

      2 홍승봉, "뇌파의 전기생리학" 대한신경과학회 21 (21): 1-238, 2003

      3 문혜진, "뇌전증과 사망" 대한신경과학회 38 (38): 1-8, 2020

      4 허선희, "간질 환자의 우울과 불안: 인구학적 요인 및 간질 관련 요인과의 관계" 대한신경과학회 27 (27): 375-383, 2009

      5 Benbadis SR, "When drugs don’t work : an algorithmic approach to medically intractable epilepsy" 55 : 1780-1784, 2000

      6 Schijns OEMG, "The start and development of epilepsy surgery in Europe : a historical review" 38 : 447-461, 2015

      7 Seeck M, "The standardized EEG electrode array of the IFCN" 128 : 2070-2077, 2017

      8 Jung JW, "The relationship between febrile convulsion and temporal lobe epilepsy : is febrile convulsion a preferential association with temporal lobe epilepsy?" 18 : 409-413, 2000

      9 Gaitatzis A, "The mortality of epilepsy revisited" 6 : 3-13, 2004

      10 Cockerell OC, "The mortality of epilepsy" 9 : 93-96, 1996

      1 김광덕, "측두엽간질에서 경막하 선형전극술:반구간 전파 시간과 수술 예후와의 연관성" 대한신경과학회 20 (20): 497-503, 2002

      2 홍승봉, "뇌파의 전기생리학" 대한신경과학회 21 (21): 1-238, 2003

      3 문혜진, "뇌전증과 사망" 대한신경과학회 38 (38): 1-8, 2020

      4 허선희, "간질 환자의 우울과 불안: 인구학적 요인 및 간질 관련 요인과의 관계" 대한신경과학회 27 (27): 375-383, 2009

      5 Benbadis SR, "When drugs don’t work : an algorithmic approach to medically intractable epilepsy" 55 : 1780-1784, 2000

      6 Schijns OEMG, "The start and development of epilepsy surgery in Europe : a historical review" 38 : 447-461, 2015

      7 Seeck M, "The standardized EEG electrode array of the IFCN" 128 : 2070-2077, 2017

      8 Jung JW, "The relationship between febrile convulsion and temporal lobe epilepsy : is febrile convulsion a preferential association with temporal lobe epilepsy?" 18 : 409-413, 2000

      9 Gaitatzis A, "The mortality of epilepsy revisited" 6 : 3-13, 2004

      10 Cockerell OC, "The mortality of epilepsy" 9 : 93-96, 1996

      11 Uldall P, "The misdiagnosis of epilepsy in children admitted to a tertiary epilepsy centre with paroxysmal events" 91 : 219-221, 2006

      12 Schaul N, "The fundamental neural mechanisms of electroencephalography" 106 : 101-107, 1998

      13 Shorvon SD, "The etiologic classification of epilepsy" 52 : 1052-1057, 2011

      14 Donald W. Klass, "The Continuing Challenge of Artifacts in the EEG" Informa UK Limited 35 (35): 239-269, 2015

      15 Sellers MC, "Technical tips : electrode application and preventing skin breakdown techniques" 51 : 206-219, 2011

      16 Martha F. Coyne, "Technical Tips: Polarity and Localization" Informa UK Limited 45 (45): 262-270, 2015

      17 Gonzalez-Martinez J, "Stereoelectroencephalography in the"difficult to localize"refractory focal epilepsy : early experience from a north american epilepsy center" 54 : 323-330, 2013

      18 Oh DH, "Seizure-related injuries in epileptic patients" 16 : 474-479, 1998

      19 Berg AT, "Revised terminology and concepts for organization of seizures and epilepsies : report of the ILAE commission on classification and terminology, 2005–2009" 51 : 676-685, 2010

      20 Cockerell OC, "Remission of epilepsy : results from the national general practice study of epilepsy" 346 : 140-144, 1995

      21 Matti Sillanpaa, "Remission of Seizures and Predictors of Intractability in Long-Term Follow-Up" Wiley 34 (34): 930-936, 1993

      22 Swinkels WA, "Psychiatric comorbidity in epilepsy" 7 : 37-50, 2005

      23 Abraham K, "Patterns of cortical discharges and their relation to routine scalp electroencephalography" 10 : 447-461, 1958

      24 Benbadis SR, "Overinterpretation of EEGs and misdiagnosis of epilepsy" 20 : 42-44, 2003

      25 Benbadis SR, "Outcome of prolonged video-EEG monitoring at a typical referral epilepsy center" 45 : 1150-1153, 2004

      26 "Office of the President" Office of the President

      27 Tatum WO 4th, "Normal adult EEG and patterns of uncertain significance" 23 : 194-207, 2006

      28 Josephson CB, "Neurocardiogenic syncope : frequency and consequences of its misdiagnosis as epilepsy" 34 : 221-224, 2007

      29 Kennedy JD, "Neocortical temporal lobe epilepsy" 29 : 366-370, 2012

      30 Mullin JP, "Is SEEG safe? A systematic review and meta-analysis of stereoelectroencephalography–related complications" 57 : 386-401, 2016

      31 Koo DL, "Intraoperative and extraoperative neurophysiological monitoring in epilepsy surgery" 3 : 16-22, 2021

      32 Jr Engel J, "ILAE classification of epilepsy syndromes" 70 : 5-10, 2006

      33 Abel TJ, "Frameless robot-assisted stereoelectroencephalography in children : technical aspects and comparison with Talairach frame technique" 22 : 37-46, 2018

      34 이서영, "Estimating the Prevalence of Treated Epilepsy Using Administrative Health Data and Its Validity: ESSENCE Study" 대한신경과학회 12 (12): 434-440, 2016

      35 Selim R. Benbadis, "Errors in EEG Interpretation and Misdiagnosis of Epilepsy" S. Karger AG 59 (59): 267-271, 2008

      36 Speckmann EJ, "Electroencephalography:basic principles, clinical applications and related fields" Williams & Wilkins 15-27, 1999

      37 Kwan P, "Early identification of refractory epilepsy" 342 : 314-319, 2000

      38 Bearden S, "EEG reviewing/recording strategy" 47 : 1-19, 2007

      39 S J M Smith, "EEG in the diagnosis, classification, and management of patients with epilepsy" BMJ 76 (76): ii2-ii7, 2005

      40 Wennberg R, "EEG and MEG in mesial temporal lobe epilepsy : where do the spikes really come from?" 122 : 1295-1313, 2011

      41 Kim YS, "Differential findings of ictal EEG pattern between mesial and neocortical temporal lobe epilepsies" 16 : 293-301, 1998

      42 Buzsaki G, "Current practice of clinical electroencephalography" Lippincott Williams &Wilkins 1-11, 2003

      43 Glover JR, "Context-based automated detection of epileptogenic sharp transients in the EEG : elimination of false positives" 36 : 519-527, 1989

      44 Tatum WO, "Clinical utility of EEG in diagnosing and monitoring epilepsy in adults" 129 : 1056-1082, 2018

      45 Suh HA, "Clinical indications and efficacies of video-electroencephalographic monitoring in the diagnosis and treatment of childhood epilepsy" 10 : 118-124, 2006

      46 Dekaban AS, "Changes in brain weights during the span of human life : relation of brain weights to body heights and body weights" 4 : 345-356, 1978

      47 Izac MSM, "Basic anatomy and physiology of sleep" 46 : 18-38, 2006

      48 Tatum WO, "Artifact and recording concepts in EEG" 28 : 252-263, 2011

      49 Tatum WO, "Artifact : recording EEG in special care units" 28 : 264-277, 2011

      50 Tatum WO 4th, "Antiepileptic drugs : adverse effects and drug interactions" 16 : 136-158, 2010

      51 Seo DW, "An easy style of EEG" Koonja Publish 2010

      52 Hirsch LJ, "American clinical neurophysiology society’s standardized critical care EEG terminology : 2021 version" 38 : 1-29, 2021

      53 Kuratani J, "American clinical neurophysiology society guideline 5 : minimum technical standards for pediatric electroencephalography" 56 : 266-275, 2016

      54 Halford JJ, "American clinical neurophysiology society guideline 4 : recording clinical EEG on digital media" 56 : 261-265, 2016

      55 Acharya JN, "American clinical neurophysiology society guideline 3 : a proposal for standard montages to be used in clinical EEG" 56 : 253-260, 2016

      56 Acharya JN, "American clinical neurophysiology society guideline 2 : guidelines for standard electrode position nomenclature" 56 : 245-252, 2016

      57 Sinha SR, "American clinical neurophysiology society guideline 1 : minimum technical requirements for performing clinical electroencephalography" 56 : 235-244, 2016

      58 Fountain NB, "American academy of neurology epilepsy measure development panel and the American medical association-convened physician consortium for performance improvement independent measure development process. Quality improvement in neurology: AAN epilepsy quality measures: report of the quality measurement and reporting subcommittee of the american academy of neurology" 76 : 94-99, 2011

      59 Maria DeBurgo, "Alternative Reference Electrode Placements" Informa UK Limited 47 (47): 203-215, 2015

      더보기

      동일학술지(권/호) 다른 논문

      동일학술지 더보기

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2026 평가예정 재인증평가 신청대상 (재인증)
      2020-01-01 평가 등재학술지 유지 (재인증) KCI등재
      2017-01-01 평가 등재학술지 선정 (계속평가) KCI등재
      2016-01-01 평가 등재후보학술지 유지 (계속평가) KCI등재후보
      2015-01-08 학술지명변경 한글명 : 대한임상검사학회지 -> 대한임상검사과학회지
      외국어명 : 미등록 -> Korean Journal of Clinical Laboratory Science
      KCI등재후보
      2014-06-25 학회명변경 한글명 : 대한임상검사학회 -> 대한임상검사과학회
      영문명 : The Korean Society for Clinical Laboratory Science -> Korean Society for Clinical Laboratory Science
      KCI등재후보
      2014-01-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      2004-12-17 학회명변경 영문명 : The Korean Society Of Biomedical Laboratory Science -> The Korean Society for Clinical Laboratory Science
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.43 0.43 0.36
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.31 0.28 0.34 0.12
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼