RISS 학술연구정보서비스

검색

인기 검색어

    다국어 입력

    http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

    변환된 중국어를 복사하여 사용하시면 됩니다.

    예시)
    • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
    • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
    닫기

    광중합 코팅제에 따른 수복용 글라스 아이오노머 시멘트의 경도 변화 = EFFECT OF LIGHT-CURED COATING AGENTS ON THE HARDNESS OF RESTORATIVE GLASS IONOMER EMENTS

    한글로보기

    https://www.riss.kr/link?id=A18638479

    • 0

      상세조회
    • 0

      다운로드
    서지정보 열기
    • 내보내기
    • 내책장담기
    • 공유하기
    • 오류접수

    부가정보

    다국어 초록 (Multilingual Abstract) kakao i 다국어 번역

    This study was done to compare the effect of various surface coating on harness for three different glass ionomer cements. The glass ionomer cements used were self-curing, light-curing and water hardening glass ionomer cement.
    The experimental groups were coated with Fuji Coat LC, Ketac-Glaze, Fortify, Schotchbond 2 and Fuji Vanish while the control group was uncoated. The half of the experimental groups were stored in 37℃ air, and the others wee placed in lactic acid solution. The surface harness for each specimen was then measured after 15 minutes, 1 hour, 1 day, 7 days and 30 days using a Vickers microhardness tester.
    From the experiment, the following results wer obtained ;
    1. In general for the glass ionomer cements without protective surface coating, stroing in air showed the large hardness number and produced dehydration, which caused increase in hardness with time. After immediately mixing (15 min.) of cements, the glass ionomer cements without surface coating ranked in order of high value of surface hardness were water-hardening, glass ionomer cement, light-curing glass ionomer cement and self-curing glass ionomer cement.
    2. The hardness of the glass ionomer cement with aged in lactic acid soultion was smaller than that in air. The surface damage resulting from dissolution in lactic acid caused a commensurate decrease in harness with time.
    3. The combination of the self-cured glass ionomer cements and GL or FCS coating material appeared to be more effective than others in providing an enhanced hardness. The light-cured glass ionomer cement showed a relatively high in surface harness when the surface coating materials KGL, FCS and SLA were applied. The FCS coating material leaded to a significant improvement in the surface hardness for the water-hardened glass ionomer cement.
    번역하기

    This study was done to compare the effect of various surface coating on harness for three different glass ionomer cements. The glass ionomer cements used were self-curing, light-curing and water hardening glass ionomer cement. The experimental groups...

    This study was done to compare the effect of various surface coating on harness for three different glass ionomer cements. The glass ionomer cements used were self-curing, light-curing and water hardening glass ionomer cement.
    The experimental groups were coated with Fuji Coat LC, Ketac-Glaze, Fortify, Schotchbond 2 and Fuji Vanish while the control group was uncoated. The half of the experimental groups were stored in 37℃ air, and the others wee placed in lactic acid solution. The surface harness for each specimen was then measured after 15 minutes, 1 hour, 1 day, 7 days and 30 days using a Vickers microhardness tester.
    From the experiment, the following results wer obtained ;
    1. In general for the glass ionomer cements without protective surface coating, stroing in air showed the large hardness number and produced dehydration, which caused increase in hardness with time. After immediately mixing (15 min.) of cements, the glass ionomer cements without surface coating ranked in order of high value of surface hardness were water-hardening, glass ionomer cement, light-curing glass ionomer cement and self-curing glass ionomer cement.
    2. The hardness of the glass ionomer cement with aged in lactic acid soultion was smaller than that in air. The surface damage resulting from dissolution in lactic acid caused a commensurate decrease in harness with time.
    3. The combination of the self-cured glass ionomer cements and GL or FCS coating material appeared to be more effective than others in providing an enhanced hardness. The light-cured glass ionomer cement showed a relatively high in surface harness when the surface coating materials KGL, FCS and SLA were applied. The FCS coating material leaded to a significant improvement in the surface hardness for the water-hardened glass ionomer cement.

    더보기

    동일학술지(권/호) 다른 논문

    동일학술지 더보기

    더보기

    분석정보

    View

    상세정보조회

    0

    Usage

    원문다운로드

    0

    대출신청

    0

    복사신청

    0

    EDDS신청

    0

    동일 주제 내 활용도 TOP

    더보기

    주제

    연도별 연구동향

    연도별 활용동향

    연관논문

    연구자 네트워크맵

    공동연구자 (7)

    유사연구자 (20) 활용도상위20명

    이 자료와 함께 이용한 RISS 자료

    나만을 위한 추천자료

    해외이동버튼