RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재

      접지방식에 따른 저압 직류배전계통의 고장특성 분석

      한글로보기

      https://www.riss.kr/link?id=A100278376

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Recently, DC distribution system has come into the spotlight as the number of digital loads and the use of renewable energy increases. However, there are still challenges for the commercialization of DC distribution system such as a consideration for the safety. Thus, researches on protective coordination and grounding system for the safety of human bodies and facilities in Low-Voltage DC (LVDC) distribution system should be preferentially conducted. In this paper, therefore, we analyze characteristics of faults in LVDC system accroding to type of grounding system based on IEC 60364. Finally, the simulations for fault characteristic in different grounding scheme are conducted using ElectroMagnetic Transient Program(EMTP) and the results of simulation are shown.
      번역하기

      Recently, DC distribution system has come into the spotlight as the number of digital loads and the use of renewable energy increases. However, there are still challenges for the commercialization of DC distribution system such as a consideration for ...

      Recently, DC distribution system has come into the spotlight as the number of digital loads and the use of renewable energy increases. However, there are still challenges for the commercialization of DC distribution system such as a consideration for the safety. Thus, researches on protective coordination and grounding system for the safety of human bodies and facilities in Low-Voltage DC (LVDC) distribution system should be preferentially conducted. In this paper, therefore, we analyze characteristics of faults in LVDC system accroding to type of grounding system based on IEC 60364. Finally, the simulations for fault characteristic in different grounding scheme are conducted using ElectroMagnetic Transient Program(EMTP) and the results of simulation are shown.

      더보기

      목차 (Table of Contents)

      • Abstract
      • 1. 서론
      • 2. 저압 직류배전계통의 접지방식
      • 3. 저압 직류배전계통의 고장 형태
      • 4. 시뮬레이션
      • Abstract
      • 1. 서론
      • 2. 저압 직류배전계통의 접지방식
      • 3. 저압 직류배전계통의 고장 형태
      • 4. 시뮬레이션
      • 5. 결론
      • References
      더보기

      참고문헌 (Reference)

      1 Bok-Hee Lee, "The Major Foundational Technics for Grounding Systems" Uijae LTd 1-197, 1999

      2 K. Engelen, "The Feasibility of Small-Scale Residential DC Distribution Systems" 2618-2623, 2006

      3 "Low voltage electrical installations-Part 1 : Fundamental principles, assessment of general characteristics, definitions, IEC 60364-1"

      4 Hirose. K, "Grounding concept considerations and recommendations ofr 400VDC distribution system" 1-8, 2011

      5 Jae-Do Park, "Fault Detection and Isolation in Low Voltage DC-Bus Microgrid System" 28 (28): 779-787, 2013

      6 "Effect of current on human beings and livestock-Part 1 : General aspects, IEC 60479-1"

      7 Navigant Research, "Direct Current Distribution Networks" 2013

      8 P. Salonen, "An LVDC distribution system concept" A3-1-A3-16, 2008

      9 E. Amiri, "A Probabilistic Approach for Human Safety Evaluation of Grounding Grids in the Transient Regime" 27 (27): 945-952, 2012

      1 Bok-Hee Lee, "The Major Foundational Technics for Grounding Systems" Uijae LTd 1-197, 1999

      2 K. Engelen, "The Feasibility of Small-Scale Residential DC Distribution Systems" 2618-2623, 2006

      3 "Low voltage electrical installations-Part 1 : Fundamental principles, assessment of general characteristics, definitions, IEC 60364-1"

      4 Hirose. K, "Grounding concept considerations and recommendations ofr 400VDC distribution system" 1-8, 2011

      5 Jae-Do Park, "Fault Detection and Isolation in Low Voltage DC-Bus Microgrid System" 28 (28): 779-787, 2013

      6 "Effect of current on human beings and livestock-Part 1 : General aspects, IEC 60479-1"

      7 Navigant Research, "Direct Current Distribution Networks" 2013

      8 P. Salonen, "An LVDC distribution system concept" A3-1-A3-16, 2008

      9 E. Amiri, "A Probabilistic Approach for Human Safety Evaluation of Grounding Grids in the Transient Regime" 27 (27): 945-952, 2012

      더보기

      동일학술지(권/호) 다른 논문

      동일학술지 더보기

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2027 평가예정 재인증평가 신청대상 (재인증)
      2021-01-01 평가 등재학술지 유지 (재인증) KCI등재
      2018-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2015-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2014-01-08 학술지명변경 외국어명 : 미등록 -> Journal of the Korean Institute of Illuminating and Electrical Installation Engineers KCI등재
      2011-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2009-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2007-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2004-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2003-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2001-07-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.17 0.17 0.19
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.18 0.17 0.342 0.05
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼