Electric and electromagnetic surveys were conducted to investigate the deep structure of the Ulsan fault in Ipsil area, south of Kyeongju. On this study, especially high-frequency magnetotelluric method of electromagnetic survey in the frequency range...
Electric and electromagnetic surveys were conducted to investigate the deep structure of the Ulsan fault in Ipsil area, south of Kyeongju. On this study, especially high-frequency magnetotelluric method of electromagnetic survey in the frequency range of 10~100,000 Hz was mainly employed to study the deep subsurface configuration. High-frequency MT survey was performed at 70 points of spacing 30~50 m, making 3.8 km survey line. As a survey result, a 2-km-depth 2-D cross-section was achieved. It shows vertical and horizontal subsurface variations of resistivity values. Near-surface layer having low resistivity value becomes thicker eastward up to 800m. There is a steep low resistivity zone in the west side of survey line, and there exists two low resistivity zones dipping west in the east side of survey line. Two low resistivity zones are interpreted to be related to major movement pattern of the Ulsan fault. This suggests that major fault lines are developed on both peripheral sides of the broad fault zone.