RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      뒤넙다리근에 대한 스트레칭과 초음파 적용의 상호작용에 의한 효과분석

      한글로보기

      https://www.riss.kr/link?id=A108141590

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      The hamstring are known to be more prone to stiffness and shortening due to an increase in non-constrictive tissue compared to other muscles. Stretching is commonly used in the clinic, but there is a lack of research on the additional effects of ultrasound. Therefore, the purpose of this study was to investigate the effect of ultrasound-stretched stretching when the hamstring were shortened clinically. Ten healthy male reserve official training corps (ROTC) were measured using the goniometer, measuring the angle of the femoral foot, pelvic inclination using PALM, muscle strength using FET, and flexibility using the Reachtoe measuring devices. The measurements were taken four weeks before the experiment, after the intervention, and five weeks later to confirm retention of flexibility. These results confirmed that the application of ultrasound was not effective in stretching the hamstring. Although we thought the increased flexibility would be maintained after a week of mediation, most of them were seen trying to get back to the way they were because of different lifestyles. Therefore, the flexibility of the hamstring can be considered as a therapeutic intervention to prevent injury when stretched, but the effect of ultrasound was found to be insignificant.
      번역하기

      The hamstring are known to be more prone to stiffness and shortening due to an increase in non-constrictive tissue compared to other muscles. Stretching is commonly used in the clinic, but there is a lack of research on the additional effects of ultra...

      The hamstring are known to be more prone to stiffness and shortening due to an increase in non-constrictive tissue compared to other muscles. Stretching is commonly used in the clinic, but there is a lack of research on the additional effects of ultrasound. Therefore, the purpose of this study was to investigate the effect of ultrasound-stretched stretching when the hamstring were shortened clinically. Ten healthy male reserve official training corps (ROTC) were measured using the goniometer, measuring the angle of the femoral foot, pelvic inclination using PALM, muscle strength using FET, and flexibility using the Reachtoe measuring devices. The measurements were taken four weeks before the experiment, after the intervention, and five weeks later to confirm retention of flexibility. These results confirmed that the application of ultrasound was not effective in stretching the hamstring. Although we thought the increased flexibility would be maintained after a week of mediation, most of them were seen trying to get back to the way they were because of different lifestyles. Therefore, the flexibility of the hamstring can be considered as a therapeutic intervention to prevent injury when stretched, but the effect of ultrasound was found to be insignificant.

      더보기

      목차 (Table of Contents)

      • Ⅰ. 서론 Ⅱ. 연구방법 Ⅲ. 연구결과 Ⅳ. 고찰 Ⅴ. 결론 Ⅵ. 참고문헌
      • Ⅰ. 서론 Ⅱ. 연구방법 Ⅲ. 연구결과 Ⅳ. 고찰 Ⅴ. 결론 Ⅵ. 참고문헌
      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼