      플립칩 접합용 초음파 혼의 CFD 열유동 해석

      한글로보기

      https://www.riss.kr/link?id=A76330463

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      This paper introduce the CFD analysis for predicting the heat transfer at the Ultrasonic horn. Approximately Ultrasonic horn separates two part. One is preheating part and the other is cooling part. Temperature of preheating part rise up by 260℃ that make it possible to attach a chip to a semiconductor. Also there is a piezo material in the cooling part. When piezo work, it generates heat of 100℃. It can stand by 150℃. But the high temperature conducted from the preheating part has a bad affect on the piezo. These situation make it necessary cooling at piezo. Previously except of the piezo, all of them are composed of the SUS440c that has good thermal conductivity. This study shows way that not only cooling the piezo but also cutting off the conduction between preheating part and cooling part by using the Ti and Duralumin that have low thermal conductivity compare with the SUS440c. Conclusion of CFD analysis that the heat coming from the piezo can`t be transferred the horn cause of the Ti and Duralumin.
      번역하기

      This paper introduce the CFD analysis for predicting the heat transfer at the Ultrasonic horn. Approximately Ultrasonic horn separates two part. One is preheating part and the other is cooling part. Temperature of preheating part rise up by 260℃ tha...

      This paper introduce the CFD analysis for predicting the heat transfer at the Ultrasonic horn. Approximately Ultrasonic horn separates two part. One is preheating part and the other is cooling part. Temperature of preheating part rise up by 260℃ that make it possible to attach a chip to a semiconductor. Also there is a piezo material in the cooling part. When piezo work, it generates heat of 100℃. It can stand by 150℃. But the high temperature conducted from the preheating part has a bad affect on the piezo. These situation make it necessary cooling at piezo. Previously except of the piezo, all of them are composed of the SUS440c that has good thermal conductivity. This study shows way that not only cooling the piezo but also cutting off the conduction between preheating part and cooling part by using the Ti and Duralumin that have low thermal conductivity compare with the SUS440c. Conclusion of CFD analysis that the heat coming from the piezo can`t be transferred the horn cause of the Ti and Duralumin.

      더보기

      목차 (Table of Contents)

      • Abstract
      • 1. 서론
      • 2. 모델링 및 지배방정식
      • 3. 결과
      • 4. 결론
      • Abstract
      • 1. 서론
      • 2. 모델링 및 지배방정식
      • 3. 결과
      • 4. 결론
      • 후기
      • 참고문헌
      더보기

      동일학술지(권/호) 다른 논문

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼