      5급 와동에서 수종의 상아질 접착제와 복합레진의 종류에 따른 미세누출 = RESEARCH ARTICLES : The Microleakage in Class V Cavity Based on Different Kinds of Several Dentin Adhesive and Composite Resin

      한글로보기

      https://www.riss.kr/link?id=A99807724

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      In order to explore microleakage in class V cavity based on different kinds of several dentin adhesive and composite resin, 2 kinds of composite resin was restored and exposed after applying 4 kinds of dentin adhesives. Deposited in methylene blue solution for 4 hours and cut in parallel with tooth longitudinal axis. By observing dye penetration level of enamel and dentin margins of each restored resin following conclusion was obtained. 1. In composite resin Filtek Z350XT Universal (3M/ESPE Dental Products, USA) in enamel margin, Easy Bond (3M/ESPE Dental Products) showed the lowest microleakage and this leakage was represented to be high in the order of Single Bond 2 (3M/ESPE Dental Products), Scotchbond Multi-Purpose (3M/ESPE Dental Products) and Cearfil SE Bond (Kuraray Medical Inc., Japan). In case of Filtek Z350XT Flowable (3M/ESPE Dental Products), Scotchbond Multi-Purpose showed the lowest microleakage and this leakage was represented to be high in the order of Single Bond 2, Clearfil SE Bond and Easy Bond. 2. In case of Filtek Z350XT Universal in dentin margin, Easy Bond showed the lowest microleakage and this leakage was represented to be high in the order of Scotchbond Multi-Purpose, Single Bond 2 and Clearfil SE Bond. In case of Filtek Z350XT Flowable, Scotchbond Multi-Purpose and Single Bond showed the lowest microleakage and this leakage was represented to be high in the order of Clearfil SE Bond and Easy Bond. 3. In all the groups excepting S-U group (Single Bond 2+Filtek Z350XT Universal), enamel margin showed more higher microleakage than that of dentin margin. 4. There was a difference between enamel and dentin margin among each group but it was not significant statistically (p>0.05). When summarizing this result, it is considered that composite resin and dentin adhesive could be applied selectively and particularly in case of applying 1-step self-etching dentin adhesive, this method would be advantageous for manipulation convenience and shortening of operation time.
      번역하기

      In order to explore microleakage in class V cavity based on different kinds of several dentin adhesive and composite resin, 2 kinds of composite resin was restored and exposed after applying 4 kinds of dentin adhesives. Deposited in methylene blue sol...

      In order to explore microleakage in class V cavity based on different kinds of several dentin adhesive and composite resin, 2 kinds of composite resin was restored and exposed after applying 4 kinds of dentin adhesives. Deposited in methylene blue solution for 4 hours and cut in parallel with tooth longitudinal axis. By observing dye penetration level of enamel and dentin margins of each restored resin following conclusion was obtained. 1. In composite resin Filtek Z350XT Universal (3M/ESPE Dental Products, USA) in enamel margin, Easy Bond (3M/ESPE Dental Products) showed the lowest microleakage and this leakage was represented to be high in the order of Single Bond 2 (3M/ESPE Dental Products), Scotchbond Multi-Purpose (3M/ESPE Dental Products) and Cearfil SE Bond (Kuraray Medical Inc., Japan). In case of Filtek Z350XT Flowable (3M/ESPE Dental Products), Scotchbond Multi-Purpose showed the lowest microleakage and this leakage was represented to be high in the order of Single Bond 2, Clearfil SE Bond and Easy Bond. 2. In case of Filtek Z350XT Universal in dentin margin, Easy Bond showed the lowest microleakage and this leakage was represented to be high in the order of Scotchbond Multi-Purpose, Single Bond 2 and Clearfil SE Bond. In case of Filtek Z350XT Flowable, Scotchbond Multi-Purpose and Single Bond showed the lowest microleakage and this leakage was represented to be high in the order of Clearfil SE Bond and Easy Bond. 3. In all the groups excepting S-U group (Single Bond 2+Filtek Z350XT Universal), enamel margin showed more higher microleakage than that of dentin margin. 4. There was a difference between enamel and dentin margin among each group but it was not significant statistically (p>0.05). When summarizing this result, it is considered that composite resin and dentin adhesive could be applied selectively and particularly in case of applying 1-step self-etching dentin adhesive, this method would be advantageous for manipulation convenience and shortening of operation time.