The purpose of this study was to evaluate the change of phase transformation and mechanical properties of orthodontic Ni-Ti wire by temperatures changes (0 ℃, 20 ℃, 37 ℃ and 60 ℃) using three-point bending tests and to investigate the phase tr...
http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
https://www.riss.kr/link?id=A30008668
2003
Korean
515.12
KCI등재
학술저널
123-145(23쪽)
0
0
상세조회0
다운로드다국어 초록 (Multilingual Abstract)
The purpose of this study was to evaluate the change of phase transformation and mechanical properties of orthodontic Ni-Ti wire by temperatures changes (0 ℃, 20 ℃, 37 ℃ and 60 ℃) using three-point bending tests and to investigate the phase tr...
The purpose of this study was to evaluate the change of phase transformation and mechanical properties of orthodontic Ni-Ti wire by temperatures changes (0 ℃, 20 ℃, 37 ℃ and 60 ℃) using three-point bending tests and to investigate the phase transformation behavior by microstructure analysis and X-ray diffraction in greater detail. The transition temperature range (TTR) of orthodontic Ni-Ti wires was analysed by DSC for the reference of proportion of martensite to austenite matrix. From this study the following results were obtained. In SM group, as the temperature decreased to 20 ℃ and 0 ℃, superelasticity loop showing at 37 ℃ in load-deflection curve disappeared and the critical load of stress induced martensite transformation decreased (p<0.01). In SE group, the load increased as the temperature increased as the temperature increased under certain temperature (p<0.01). From the microscope, the proportion of stripe-shaped martensite plate to austenite matrix was higher in NEO, active martensite alloy, than OPTI, the active austenite alloy. The (002) peak indicating martensite phase clearly appeared when the temperature decreased to -20 ℃ in NEO from the X-ray diffraction spectra. This study indicated that mechanical properties of orthodontic Ni-Ti wires were substantially affected by temperature and we could expect the biological response in periodontal ligament by load fluctuation of wires tied in bracket induced by temperature variation.
치주조직 재생을 위한 칼슘 포스페이트 글라스 분말이 백서 두개골 결손부의 골조직 재생에 미치는 영향
미소압입시험법과 SEM/EPMA를 이용한 치과용 금속-세라믹 시스템의 계면특성 연구
치주조직 재생을 위한 칼슘 포스페이트 글라스가 MC3T3-E1 세포의 증식, 분화 및 석회화에 미치는 영향
학술지 이력
연월일 | 이력구분 | 이력상세 | 등재구분 |
---|---|---|---|
2026 | 평가예정 | 재인증평가 신청대상 (재인증) | |
2020-01-01 | 평가 | 등재학술지 유지 (재인증) | ![]() |
2017-01-01 | 평가 | 등재학술지 유지 (계속평가) | ![]() |
2014-11-11 | 학회명변경 | 한글명 : 대한치과기재학회 -> 대한치과재료학회영문명 : The Korea Research Society For Dental Materials -> Korean Society For Dental Materials | ![]() |
2014-11-11 | 학술지명변경 | 한글명 : 대한치과기재학회지 -> 대한치과재료학회지외국어명 : J. Korea Res. Soc. Dent. Mater. -> Korean Journal of Dental Materials | ![]() |
2013-01-01 | 평가 | 등재학술지 유지 (등재유지) | ![]() |
2010-01-01 | 평가 | 등재 1차 FAIL (등재유지) | ![]() |
2008-01-01 | 평가 | 등재학술지 유지 (등재유지) | ![]() |
2006-01-01 | 평가 | 등재학술지 유지 (등재유지) | ![]() |
2003-01-01 | 평가 | 등재학술지 선정 (등재후보2차) | ![]() |
2002-01-01 | 평가 | 등재후보 1차 PASS (등재후보1차) | ![]() |
2000-07-01 | 평가 | 등재후보학술지 선정 (신규평가) | ![]() |
학술지 인용정보
기준연도 | WOS-KCI 통합IF(2년) | KCIF(2년) | KCIF(3년) |
---|---|---|---|
2016 | 0.33 | 0.33 | 0.25 |
KCIF(4년) | KCIF(5년) | 중심성지수(3년) | 즉시성지수 |
0.2 | 0.18 | 0.408 | 0.07 |